background image

 

15 

Screen Display 

Operating Instructions 

Displayed State

 

Sound and 

Backlight Color

 

 

 

 

 

 

When putting on the probe cover, 
press the

 Mode button

 to switch 

between object and forehead 
modes. Ear mode (adult/child) will 
be activated by removing the probe 
cover. 

 

Silent, the 

backlight is green. 

Switching between ºF/ºC 

 

 

In a power-on state,you can change 
units, by switching the 

ºF/ºC 

button

Silent 

Summary of Contents for LS-320

Page 1: ...LS 320 Infrared Thermometer Instruction Manual Genesis Biotech Pty Ltd LifeSmart Manual Version 1 0 Date of Issue 2019 02 0482...

Page 2: ...ual mode infrared thermometer can scan either the forehead or the ear within one second Its special ergonomic design facilities easy operation With its storage memory of 20 readings the user can easil...

Page 3: ...ight Color Instructions 9 Display and Operating Instructions 10 Measuring Ear Temperature 16 Measuring Forehead Temperature 18 Measuring Object Temperature 18 Replacing Batteries 20 Cleaning and Disin...

Page 4: ...number purchase date and your contact information and address Package Contents No Name Quantity 1 Infrared Thermometer 1 2 Pouch 1 3 Battery AAA 2 4 Instruction Manual 1 Safety Precautions Read the f...

Page 5: ...an and disinfect the thermometer as described in the Cleaning and Disinfection chapter Do not touch the tip of the temperature probe on which a precise temperature sensor resides Keep the temperature...

Page 6: ...ned measurement results For such purposes please consult a doctor Do not charge an alkaline dry cell battery or throw it in fire Otherwise the battery may explode Do not disassemble the thermometer or...

Page 7: ...tion point for recycling IP22 Degree of protection against the Ingress of water Warning A personal injury or damage to the thermometer may occur if the thermometer is not used correctly Attention Inac...

Page 8: ...temperatures than adults and adults have higher body temperatures than the elderly Women s body temperatures are approximately 0 3 C 0 5 F higher than men s Variation in body temperature Body Site Nor...

Page 9: ...infrared temperature sensor and a Microprocessor 3 Operating principle The infrared temperature sensor collects infrared energy emitted by the eardrum or the skin surface After being focused by a lens...

Page 10: ...tivity High accuracy with automatic temperature calibration 05 Diverse functions 20 readings recall Fever alert Switching between C and F Automatic power off power saving 06 Extensive application scop...

Page 11: ...mode Child mode Object 5 Probe take off the cover when measuring the ear temperature 6 Probe cover Automatic switch among object forehead and ear modes by removing the probe cover to measure ear tempe...

Page 12: ...3 short double beeps Red Ear temperature Adult Child 35 0 37 5 95 0 99 5 A long beep green 37 6 42 0 99 6 107 6 3 short double beeps Red Object temperature 0 100 32 0 212 A long beep green Note When...

Page 13: ...Ear temperature for child Take off the probe cover press and release the Power button for 1 second to power on the thermometer The symbol is displayed on the screen Switch to the adult or child measur...

Page 14: ...hermometer The Head symbol is displayed on the screen Switch to the adult or child measurement mode by pressing the Mode button according to your measurement needs Point the thermometer to the center...

Page 15: ...table in the Sounds and backlight color instructions section Out of the measuring range display for reference only In Ear mode a temperature reading of more than 42 0 C 107 6 F In Forehead mode a tem...

Page 16: ...ll be shown followed by the recorded reading Press the Memory button again for the next recorded data 02 will be shown followed by the recorded reading A maximum of 20 temperature readings can be reca...

Page 17: ...long beep and a green backlight which then turns into red Switching between mute and un mute In the power on state press and hold the sound switch button for about 2 seconds to switch the sound on or...

Page 18: ...putting on the probe cover press the Mode button to switch between object and forehead modes Ear mode adult child will be activated by removing the probe cover Silent the backlight is green Switching...

Page 19: ...data is being read from or written to the memory or the temperature correction is not complete A long beep the backlight is red When the battery voltage is lower than 2 4V 0 1V the low battery symbol...

Page 20: ...ase the Measure button The ear temperature reading will be displayed on the screen instantly Note Children under 1 year Pull the ear straight back Children aged 1 year to adult Pull the ear up and bac...

Page 21: ...The temperature reading will be displayed on the screen instantly 6 If no activity is detected the thermometer will power off automatically in 10 seconds Measuring Object Temperature 1 Put the cover...

Page 22: ...oor environment without strong air convection for example winds from a fan an air conditioner or a heater between the thermometer and the person 2 Make sure that the ear canal is clean and dry before...

Page 23: ...e two AAA batteries into the compartment according to the stated polarities Make sure that the batteries are installed correctly Otherwise the thermometer may be damaged If the low battery symbol is d...

Page 24: ...off the lens during the cleaning process Otherwise the lens may be damaged The lens may be scratched if it is cleaned with a hard object which might result in inaccurate readings Do not clean the ther...

Page 25: ...meter under the temperature of 10 40 50 104 the relative humidity of 15 85 RH no condensation and the barometric pressure of 86kPa 106kPa Maintenance Preventive inspection maintenance period 1 Ensure...

Page 26: ...r Er1 is displayed The ambient temperature is lower than 10 C 50 0 F or higher than 40 C 104 F Take a measurement under an ambient temperature between 10 C 50 0 F and 40 C 104 F The temperature readin...

Page 27: ...splay Segment LCD Measure time About 1 second Latency Time About 3 seconds Measuring Range Forehead mode 35 0 C 42 2 C 95 0 F 108 0 F Ear mode 35 0 C 42 0 C 95 0 F 107 6 F Object mode 0 0 C 100 0 C 32...

Page 28: ...thermometers the requirement per ASTM Standards E667 86 and E1112 86 is 0 2 F 0 1 C Security Class Type of protection against electric shock internally powered equipment Degree of protection against e...

Page 29: ...into service according to the EMC information provided for in the ACCOMPANYING DOCUMENTS Portable and mobile RF communications equipment can affect Infrared Thermometer LS 320 The Infrared Thermometer...

Page 30: ...ems Guidance and manufacturer s declaration Electromagnetic immunity The Infrared Thermometer LS 320 is intended for use in the electromagnetic environment specified below The customer or the user of...

Page 31: ...rmometer LS 320 should ensure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Radiated RF IEC 61000 4 3 3 V m 80 MHz to...

Page 32: ...80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures obje...

Page 33: ...nd the EQUIPMENT or SYSTEM for EQUIPMENT and SYSTEMS that are not LIFE SUPPORTING The Infrared Thermometer LS 320 is intended for use in an electromagnetic environment in which radiated RF disturbance...

Page 34: ...s NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people Warranty and After Sale Service The de...

Page 35: ...2 Wellkang Ltd Suite B 29 Harley Street London W1G 9QR UK Shenzhen Jumper Medical Equipment Co Ltd Address D Building No 71 Xintian Road Fuyong Street Baoan Shenzhen Guangdong China Fax 86 755 2685202...

Page 36: ...esis Biotech Pty Ltd Level 1 16 McDougall Street MILTON QLD 4064 www mylifesmart net au CONTACT US For Australia New Zealand customers support mylifesmart net au Australian customers 1300 110 155 AEST...