RC Series Rackmount Installation Manual
8
9
Configuration and Usage
This section describes the final configuration as well as operation details for the RC Rackmount series power supplies .
2 .1 Removing the Faceplate of the Enclosure
Use the following steps to remove the faceplate of the rack-
mount enclosure and gain access to the front boards .
1 . Remove and retain the five philips head 6-32 screws
from the faceplate . DO NOT remove the four 10-32
screws securing the enclosure to the rack .
2 . Carefully remove the faceplate and set it aside in a
safe location
When configuration is complete, reverse the removal pro-
cedure to replace the cover, taking care to align the LEDs
with the holes in the faceplate (See figure 6) .
2 .2 Configuring the Zones
Input Selection (Figure 7)
These switches are used to select a normally open or normally
closed input for each zone . Switch 1 sets zone 1, switch 2 sets
zone 2, and so on . Adjust this switch so that the zone's output
LED is FLASH ING when the door is unlocked .
• OFF (NC/Fail Safe)
Set this switch to OFF for a NC contact
input (contact OPENS to unlock door) or for a voltage input
where the voltage is REMOVED to unlock the door .
• ON (NO/Fail Secure)
Set this switch to ON for a NO contact
input (contact CLOSES to unlock door) or for a voltage input
where the voltage is APPLIED to unlock the door .
FAI Selection (Figure 7)
These switches enable or disable FAI for the selected zone .
Switch 1 sets zone 1, switch 2 sets zone 2, and so on .
• ON (FAI Enabled)
When this switch is set to ON, the zone's
output will invert when the FAI input is active . This is typically
used to drop power to maglocks on a fire alarm condition .
• OFF (FAI Disabled)
When this is set to OFF, FAI will have no
effect on the zone's output .
Output Selection (Figure 8)
These switches are used to select a fail-safe or fail-secure out-
put for each zone . Switch 1 sets zone 1, switch 2 sets zone 2,
and so on . Set this switch so that the door is UNLOCKED when
the zone output LED is flashing (Zone Active) .
• ON (Fail Secure Output)
By setting this switch to ON, the
zone's output terminals will output a voltage when the zone in-
put is activated .
• OFF (Fail Safe Output)
By setting this switch to OFF, the
zone's output terminals will not output a voltage when the zone
input is activated . This posi tion is typically used for Mag Locks .
Section 2 – Configuration and Usage
A B
CONTROLLED OUTPUTS
CONTROL INPUTS
1
+
2 3 4
- + - + - + -
5
+
6 7 8
1 2 3 4
5 6 7 8
- + - + - + -
A B A B A B
A B A B A B A B
1
ON
2 3 4 5 6
8
7
1
ON
2 3 4 5 6
8
7
N.O. INPUT
N.C. INPUT
Enable FAI
Disable FAI
2
3
4
5
6
7
8
F
F
1
10 11 12 13 14 15 16
9
Figure 7 - RC Back Board
Figure 8 - RC Front Board
Figure 6 - Faceplate
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
FLT
3
—
3
3
3
3
3
3
3
3
CH1
CH2
CH3
VOLTAGE SELECT JUMPERS
DC1
DC2
Fail-Safe
OUTPUT
Fail-Secure
OUTPUT
CH4
CH5
CH6
CH7
CH8
FLT
3
3
3
3
3
3
3
3
1
ON
2
3
4
5
6
8
7