LifeSafety Power FlexPower RA100 Series Installation Manual Download Page 2

RA Series, RD Series Rackmount Installation Manual

ii

iii

 

Notes and Warnings  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .iii

Symbol Definitions   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . iii
Warnings .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . iii
Regulatory Information  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . iii
Conventions Used Within this Manual .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . iii

Introduction .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . iv
Section 1 – Installation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1

1 .1 Mounting the Rack Mount Supply into a Standard 19" Rack  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .1
1 .2 RA & RD Rackmount Power Supply Overview   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .2
1 .3 Internal Pre-Configuration - RD Series Only   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .4
1 .4 Making the Wiring Connections - RA and RD Series .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .6
FAI Input Usage .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .7

Section 2 – Configuration and Usage .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 9

2 .1  Removing the Faceplate of the Enclosure .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .9
2 .2  Configuring the Outputs  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .9
2 .3  Disabling Faults   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .9
2 .4  Status LEDs   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .9
2 .5  Remote Access via Ethernet .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .10

Section 3 – Specifications  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 11

3 .1  Electrical Specifications   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .11
3 .2  Temperature Specifications   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .13
3 .3  Mechanical Specifications   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .13

Table of Contents

RA and RA-N AC systems only operate off 

120VAC input .

RD and RD-N DC systems are factory set for 

120VAC input . To configure for 230VAC, see 
page 4, section 1 .3 .2

 

i

Summary of Contents for FlexPower RA100 Series

Page 1: ...LifeSafety Power Inc PH 888 577 2898 TechSupport LifeSafetyPower com P03 032 Rev A06 RA RD Rackmount Installation Manual...

Page 2: ...ly 4 1 4 Making the Wiring Connections RA and RD Series 6 FAI Input Usage 7 Section 2 Configuration and Usage 9 2 1 Removing the Faceplate of the Enclosure 9 2 2 Configuring the Outputs 9 2 3 Disablin...

Page 3: ...ll wiring is routed and secured to prevent accidental open or short circuit conditions iThe system and any batteries if used should be tested at least once per year to ensure proper opera tion Regulat...

Page 4: ...atures combine to significantly reduce installation and service costs Features include removable terminal strips for field wiring input and output surge suppression automotive blade fuses for im prove...

Page 5: ...s or other appropriate support for heavy enclosures Keep heavier components near the bottom of the rack to reduce the risk of toppling of a top heavy rack NOTE For UL864 Installations the Rack Mount S...

Page 6: ...h CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 FLT 1 2 3 4 5 6 7 8 3 3 3 3 3 3 3 3 1 B1 B2 JP1 2 3 CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 FLT 1 2 3 4 5 6 7...

Page 7: ...ailable on these terminals Dual power supply models will have two DC1 outputs See Section 1 4 2 for more information DC2 This is an FAI controllable bulk power output with the full power of the associ...

Page 8: ...to detect a missing bat tery set To enable battery presence detection place the BATDET jumper ON To disable battery presence detection remove the BATDET jumper or place it on only one pin See 2 in Fi...

Page 9: ...h GND Battery DETECT Voltage SELECT 230VAC jumper Figure 3 Configuring the Internal FPO Power Supplies in an RD Series Supply Figure 4 FPO 230VAC jumper location AC Input cut jumper for 230VAC cut jum...

Page 10: ...unaffected by the FAI input DC2 DC2 The DC2 output may optionally be controlled by the FAI input The full current of the FPO is available on these terminals The DC2 output may be set to power up when...

Page 11: ...Input is achieved by placing a NC contact across the two L terminals The FAI may be activated by any of the methods listed FAI Deactivates when the input is deactivated AND the NC Latching contact is...

Page 12: ...ut will damage the system and void the warranty 1 4 4 Ethernet Connection Optional RA and RD models with a model number ending in N con tain a Netlink communication ethernet module The Netlink allows...

Page 13: ...To set the operation of the FAI controlled outputs see Section 1 3 6 B1 Left Continuous Output No FAI control B2 Right FAI Controlled Output RD Series Dual Supply Models Each output is configurable f...

Page 14: ...these fields are not accurate measurements and only show the presence of voltage An approximate reading may be deter mined by multiplying the shown voltage by 0 71 Fault Notification Fault conditions...

Page 15: ...ll Load No Batt 88 120VAC 60Hz In Full Load No Batt 89 120VAC 60Hz In Full Load No Batt Battery Size Type 4 40AH Lead Acid or Gel Cell 4 80AH Lead Acid or Gel Cell 4 80AH Lead Acid or Gel Cell Charge...

Page 16: ...ad No Batt 88 120VAC 60Hz In Full Load No Batt 89 120VAC 60Hz In Full Load No Batt Battery for EACH internal supply Size Type 4 40AH Lead Acid or Gel Cell 4 80AH Lead Acid or Gel Cell 4 80AH Lead Acid...

Page 17: ...max 3A per output 7 5A zone max 3A per output 7 5A zone max 3A per output 7 5A zone max Fuse Ratings Fused Models ATM 3A 7 5A Max ATM 3A 7 5A Max ATM 3A 7 5A Max ATM 3A 7 5A Max BTU Output BTU 68 102...

Page 18: ...ty Power or its distributors be liable for any incidental indirect or consequential damages arising from the sale resale use or misuse of the product Specifications are subject to change without notic...

Reviews: