6
Depending on the type of HRV installation, you may have timers
in areas such as restrooms. The timer will override the Operational
Mode (regardless of the setting) and initiate high speed ventilation.
Upon completion of the timer cycle, the HRV will return to your
selected Operational Mode and speed setting
Lifestyle 20/40/60 Minute Timer
Part # 99-DET01
Initiates high speed ventilation for 20, 40 or 60 minutes. The
20/40/60 Minute Status Lights indicate high speed operation.
Lockout Mode is useful if you wish to disable the timer. Set
lockout by holding the Select Button for 5 seconds. Unlock by
holding for 5 seconds.
Lifestyle 20 Minute Timer
Part # 99-20M01
Initiates high speed ventilation for 20 minutes. The 20 Minute
Status Light indicates high speed operation.
Lockout Mode is useful if you wish to disable the timer. Set
lockout by holding the Select Button for 5 seconds. Unlock by
holding for 5 seconds.
Lifestyle Dehumidistat
Part # 99-DH-01
Initiates high speed ventilation when the moisture level in the
home exceeds the set point on the control. Once the humidity in
the house is reduced, the HRV will revert back to its previous
setting. The Dehumidistat should be set to OFF for all season
except the heating season.
Refer to "How the Dehumidistat Works" in this manual before
setting the Dehumidistat.
Optional Timers
Select Button
Select Button
Dehumidistat
Adjust Button
20/40/60 Minute
Status Lights
20 Minute
Status Lights
%
80
20
Dehumidistat LEDs
Set to the desired humidity
level. High speed ventilation
will initiate when the indoor
moisture level exceeds the
set point on the control.