WARRANTY
Units carry a LIFETIME warranty on the heat recovery
core and a 5 year replacement parts warranty.
Date: ___________________________________________
Tag: _____________________Qty:___________________
Project: _________________________________________
Engineer: _______________________________________
Contractor: ______________________________________
Supplier: ________________________________________
Quote#: _________________________________________
Submitted by: ____________________________________
49 "
(1245)
STALE AIR
TO OUTSIDE
FRESH AIR
TO INSIDE
14 3/4"
(375)
1
9
"
(4
8
3
)
Ports
7" (178 mm)
CONDENSATE
DRAINS
BLOWERS
*NOTE:
Front clearance of 25 inches (635 mm)
is recommended for servicing unit.
MOTOR
FRESH AIR
FROM OUTSIDE
STALE AIR
FROM INSIDE
FILTER
DEFROST
DAMPER
DEFROST AIR
FROM INSIDE
FILTER
Ports
6" (150 mm)
METAL CLASPS
ENGINEERING DATA
THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE
The cross-flow heat recovery core transfers heat between the two airstreams. The two cores
are arranged for highly efficient counter current airflow.
MOTORS AND BLOWERS
Each air stream has one centrifugal blower driven by a common ECM motor. 5 speed fan
operation. 120 VAC, 1.7 Amps.
FILTERS
Washable air filters in exhaust and supply air streams.
MOUNTING THE HRV
Four threaded inserts at corners of the cabinet designed to accept the “S” hooks and hanging
straps supplied with the unit.
DEFROST
Damper defrost system.
CASE
Twenty gauge prepainted galvanized steel (G60) for superior corrosion resistance. Insulated to
prevent exterior condensation. Drain connections 2 - 1/2" (12 mm) OD.
WEIGHT
88 lbs. (40 kg)
SHIPPING WEIGHT
92 lbs. (41.8 kg)
CONTROLS & ELECTRONICS
The
Lifestyle MAX Digital Control
(included with unit) can be wall mounted in a central
location of the home. (3 wire) 20 gauge wire (min.) 100' length
Electronic features include:
• 5 Speed Operation on each mode
• 2 user selectable operational modes: Continuous Ventilation, 20 ON/40 OFF
• Humidity Control through dehumidistat
• Adjustable Dehumidistat function built into the main wall control
• Built-in Relay for Interfacing to furnace
OPTIONAL PROGRAMMABLE CONTROL
99-LS-01
Lifestyle MAX Programmable Control
- contains all the features of the
Lifestyle MAX Digital Control with 7/24 programmable ventilation, (3 wire)
20 gauge wire (min.) 100' length
OPTIONAL TIMERS
99-DET01 Lifestyle 20/40/60 Minute Timer
- Initiates high speed ventilation for 20, 40,
or 60 minutes, (3 wire) 20 gauge wire (min.) 100' length
99-20M01 Lifestyle 20 Minute Timer
- Initiates high speed ventilation for 20 minutes,
(3 wire) 20 gauge wire (min.) 100’ length.
99-101
Mechanical Timer
- Initiates High speed ventilation for up to 60 minutes,
(2 wire) 20 gauge wire (min.) 100' length
OPTIONAL ACCESSORIES
99-DH-01 Lifestyle Dehumidistat -
Initiates high speed ventilation when the indoor
humidity level is above the set point. (3 wire) 20 gauge wire (min.) 100' length
99-163
Duct Heater w/ Electronic SCR Thermostat,
1 Kw, 6” (150 mm)
99-185
Weatherhoods
, Two - 6” (150 mm) c/w 1/4” (6 mm) mesh screen
All units conform
to CSA and UL
standards.
Model 195ECM
DIMENSIONS 195ECM
inches (mm)
*Sensible Efficiency – thermal **Latent Efficiency – moisture
ote: Effectiveness - based on temp. differential between the 2 airstreams
Efficiency – takes into account all power inputs
Performance
Net supply air flow in cfm (L/s) against external static pressure
E.S.P
(external static pressure)
[cfm (L/s)]
@ 0.1" (25 Pa)
191 (90)
@ 0.2" (50 Pa)
184 (86)
@ 0.3" (75 Pa)
177 (83)
@ 0.4" (100 Pa)
169 (80)
@ 0.5" (125 Pa)
159 (75)
@ 0.6" (150 Pa)
152 (71)
Max. Temperature Recovery
88%
Sensible Effectiveness
@ 114 cfm (54 L/s)
32°F (0°C)
85%
*Sensible Efficiency
@ 114 cfm (54 L/s)
32°F (0°C)
78%
*Sensible Efficiency
@ 119 cfm (56 L/s)
-13°F (-25°C)
69%
VAC @ 60HZ
120
WATTS / Low speed
34
WATTS / High speed
129
Amp rating
1.7
20
40
60
80
100
120
140
160
180
200
220
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
Static Pressure (in w.g.)
A
ir
F
lo
w
(c
fm
)
20
40
60
80
100
120
140
160
180
200
220
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
Pression statique extérieure (en po de colonne d’eau)
D
éb
it
d’
ai
r
(e
n
pi
c
u/
m
in
)
5 - High Speed
4 - Medium High Speed
3 - Medium Speed
2 - Medium Low Speed
1 - Low speed
5
4
3
2
1
5
4
3
2
1
5 - Haute vitesse
4 - Vitesse moyenne haute
3 - Vitesse moyenne
2 - Vitesse moyenne basse
1 - Basse vitesse
The ECM motor produces a tone that some may
find
objectionable. We recommend the
installation of the optional 99-SILENCER6 on the
‘Stale Air from Inside’ and ‘Fresh Air to Inside’
ducts.