H
SI
L
G
N
E
17
2.3.2
Operators with electric stop switches: direction, travel and speed identifi cation
The direction and travel identifi cation phases are performed at reduced speed.
PHASE 1
LEAF 2 CLOSURE STOP SWITCH IDENTIFICATION:
a) Give the step command
(A)
, holding it down until leaf
(2)
slowly reaches and pushes for a few seconds against the closure stop plate. Release the step
command
(A)
, when the micro is reached, the red LED
(DX)
will light.
b) Give the step command
(A)
, holding it down until leaf
(1)
slowly reaches and pushes for a few seconds against the closure stop plate. Release the step
command
(A)
, when the micro is reached, the red LED
(SX)
will light.
ATTENTION
If the gate does not move or struggles to move, it is necessary to raise the force value when the gate is immobile:
1) Press
A
followed by
FORCE
.
2) Press
to increase the basic force values: the
LEDs will light.
3) Press
B
to exit.
PHASE 2
IDENTIFICATION OF STAGGERING AND OPENING STOP PLATE.
a) Give the step command
(A)
and release, the leaf
(1)
will open. When it reaches the point at which one also wishes to open leaf
(2)
(opening staggering)
give the step command
(A)
and release: leaf
(2)
will open. The two leafs continue to open slowly.
b) When they have both reached the opening stop plate micros both red LEDs light.
PHASE 3
IDENTIFICATION OF CLOSURE STAGGERING AND STOP PLATE
a) Give and release the step command
(A)
: leaf
(2)
will close. When it reaches the point at which one also wishes to close leaf
(1)
(closure staggering)
give and release the step command
(A)
: leaf
(2)
will close. The leaves now both move at a normal speed when closing.
b) On reaching the closure stop plate micros, the green LEDS fl ash and the red LEDs remain lit.
The automation is now programmed
. The automation is now in semi-automatic mode by default.
If you are dissatisfi ed with the result obtained,
reset the control unit
and repeat procedure from start.
RESETTING THE CONTROL UNIT
a) Switch off the system’s power supply.
b) Press
and switch on the system’s power supply until all four LEDs light.
Adjust the position of the
(1) CLOSURE
and
(2) OPENING
mechanical plates.
OPTIMO: ADJUSTING THE OPENING AND CLOSURE MECHANICAL STOP PLATES
2222222222222222222222222222222