background image

12

LIMITED WARRANTY

America's  Remanufacturing  Company  (ARC)  warrants  this  heater  against  defects  in  materials  and 

workmanship  on  functional parts,  for  a  period  of  30 days  from  the  original  date  of  purchase.  Your 

sales receipt showing the date of purchase of the product is your proof of purchase. Keep it in a safe 

place  for  future  reference.  This  warranty  is  subject  to  personal  use  only,  commercial  or  rental 

applications will not be covered.
This  product  is  made  with  the  highest  quality  materials  and  is  warranted  to  be  free  from 

defects in  materials  and  workmanship  at  the  time  of  purchase.  This  limited  warranty  applies  to 

products  refurbished  or  distributed  by  ARC,  are  delivered  in  the  continental  United  States  and 

extends  to  the  original  purchaser,  or  gift  recipient.  This  warranty  becomes  valid  at  the  time  of 

purchase and terminates either by the specified time frame listed above and/or owner transfer. Any 

refunds  or  monetary  compensations  must  be  claimed  through  the  place  of  purchase  (retailer),  and 

not through the manufactu

rer. Any extended warranties (warranties that cover above and beyond this 

ARC  warranty)  that  are  sold  through  a  retailer  or  third  party,  are  not  directly  correlated  with  this 

products’ limited warranty, and may be redirected to said retailer or third party for coverage.
This  warranty  extends  through  America's Remanufacturing Company  of  the  product,  and  covers 

functional  parts  only.  Cosmetics  are  not  covered,  unless  unequivocally  determined  it  is  a 

workmanship  defect.  Shipping  damage  should  be  addressed  with  the  shipping  company, 

retailer,  or  place  of  purchase,  not  the manufacturer unless the manufacturer was the direct shipper.
ARC’s  sole  obligation  under  this  warranty  shall  be  limited  to  furnishing  the  original  purchaser 

replacement  parts  for  units  deemed  repairable  by  A R C ' s   warranty  department. The purchaser is 

responsible  for  insuring  any  parts  shipped  or  returned,  if  desired.  The  purchaser  is  responsible  to 

prepay  any  shipping  charges  (both  ways)  including,  but  not  limited  to  taxes  and  duties.  All 

exchanged  parts  and  products  replaced  under  this  warranty  will  become  the  property  of 

manufacturer. ARC reserves the right to change manufacturers of replacement parts or products for 

use, in order to cover any existing warranty. 
The purchaser may be asked to provide ARC with proof of purchase documents (including the date 

of  purchase)  if  requested.  Any  evidence  of  alteration,  erasing,  or  forgery  of  proof  of  purchase 

documents will be just cause to VOID this limited warranty. Products, in which the serial number has 

been defaced or removed are not eligible for warranty coverage. 

This warranty does not apply if the unit has been subject to negligence, fabrication, misuse, abuse, or 

repairs, alteration by non-ARC authorized personnel, inappropriate installations, or any case beyond 

the control of ARC. Examples of warranty invalidation may also include, but are not limited to: 

Use of lacquer or paints in (and around) the heaters 

Heater placed on non-approved surfaces 

Electrical requirement deficiencies (15-20 amp dedicated outlet)

Use on extension cords/timers/surge protectors/GFCI

Outdoor applications 

Normal wear/tear/weathering; Pet/consumer accidents

Purchases from dealers unauthorized by the America's Remanufacturing Company 

(Authorization in writing)

America's Remanufacturing Company shall not be liable for any loss due to use (or misuse) of the 

heater  or  other  incidental  or  consequential  costs,  expense  or  damages  without  irrefutable 

foundations.  Under  no  circumstances  shall  the  manufacturer  or  any  of  its  representatives  be  held 

liable for injury to any person or damage to  any  property,  however  arising.  Any  implied  warranty 

shall  have  duration  equal  of  the  applicable  warranty  stated  above.  Specifications  are  subject  to 

change without notice or obligation. 
This limited warranty gives the original purchaser specific legal rights. Other rights may vary from state 

to state.

Printed in U.S.A.

PLEASE REMEMBER TO REGISTER YOUR WARRANTY:

 

web: www.arcaugusta.com/register-my-product.htm

Summary of Contents for R-LS-W6-WIQH-M

Page 1: ...back of unit __________________ LIFE SMART is a registered trademark of Source Network Sales Marketing Inc All Rights Reserved This product is refurbished in the United States of America by America s Remanufacturing Company INFRARED QUARTZ HEATER REFURBISHED Model R LS W6 WIQH M ...

Page 2: ...nts 3 Safety Information 4 Frequently Asked Questions 8 Preparation 1D Troubleshooting 10 Control Panel 11 Remote Control 12 Operating Instructions 13 Care and Maintenance 15 Limited Warranty 16 Replacement Parts List 17 2 1JjjfSMART ...

Page 3: ......

Page 4: ...cturer for resolution options Do not use outdoors Exposure to outdoor elements such as rain snow sun wind or extreme tem peratures may cause the heater to become a safety hazard This heater is not intended for use in bathrooms laundry areas and similar indoor locations nor any locations that use GFCI outlets Never place the heater where it may fall into a bathtub or other water receptacles Do not ...

Page 5: ... that could cause overheating or possible fire the heater will automatically shut off If the unit has been overheated you will need to unplug the unit from the wall and replug it in to use the heater again WARNING This heater has a voltage rating of 120 volts The cord has a three blade ground ing type plug An adapter is available for connect ing three blade grounding type plugs to two slot recepta...

Page 6: ......

Page 7: ......

Page 8: ...rn it on how long will it take to heat my room A The heating process in the heater begins immediately upon powering on and setting the desired temperature above the ambient temperature A noticeable change in the ambient temperature of the room will vary due to variables such as the location of the heater in the home floor plan and size of the room how well the room is insulated how many doors wind...

Page 9: ...o property or injury may result if requirements are not met Q Why does my heater s fan continue to run after the set temperature is reached or the power is turned off A This is normal The heater s fan will continue to run even after the heater automatically cycles down The fan continues to run so that every last bit of heat is blown out of the heat chamber while allowing the unit to continue filte...

Page 10: ...heated basements etc TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION The heater does not turn on 1 The power cord is not plugged in 2 The electricity at the main fuse box is not working 3 The battery in the remote control is dead 4 The thermostat on the heater is set lower than the room temperature 5 The power switch in the back of the unit is not in the ON position 1 Plug the power cord ...

Page 11: ...er Indicator Light Indicates when the unit is receiving power from the wall outlet 7 Power Switch Button Powers the heater ON or OFF 8 Ambient Temp Button Indicates ambient temp hold to toggle between C F 9 Temp Down Button Decreases the set temperature 10 Temp Up Button Increases the set temperature 11 Timer Button Engages the on off timer function 12 Heater Mode Button Toggles between Hi Low Eco...

Page 12: ... Mode Button Toggles between the three heat modes available 3 Temp Down Button Decreases the set temperature value 4 Power Button Powers the heater on or off 5 Ambient Lock Button Short press Shows Ambient temperature Long press for 3 seconds to activate lock function 6 Timer Button Engages the on off timer ...

Page 13: ......

Page 14: ...the Timer button on the control panel C Note The timer power on function can only be set when the heater is in power off mode The digital display on the control panel C will indicate time value for the timer Press the Timer button repeatedly to change the num ber value between a range of 0 to 12 hours in 1 hour intervals The Timer light turns on when the timer is set 5 C B TIMER TIMER 6 To replace...

Page 15: ... heater 3 DO NOT immerse the heater in water 4 Wait until the unit is completely dry before use 5 If you will not be using the heater for a while take the batteries out of the remote control and store for future use 6 Store the heater in a cool dry location when not in use To prevent dust and dirt build up use the original packaging to repack the unit CLEANING THE AIR FILTER 1 Clean the air filter...

Page 16: ... manufacturer unless the manufacturer was the direct shipper ARC s sole obligation under this warranty shall be limited to furnishing the original purchaser replacement parts for units deemed repairable by A R C s warranty department The purchaser is responsible for insuring any parts shipped or returned if desired The purchaser is responsible to prepay any shipping charges both ways including but...

Page 17: ...at 657 341 0362 9 00 a m 5 p m CST Monday Friday PART DESCRIPTION PART A Control panel COPA H2018 B Fan FAN DC C Power board POBO H2018 D Limit switch LIMITSW130 E Infrared tube QUAR R185 F Thermostat Wire SENSOR G Master Power Switch MAINSW S H Remote control REMO H2016 A D F E B H G C ...

Reviews: