(Fig.8)
4.2.4 Move the throttle valve level away from the
LOWER
position, about 1/3 of the way toward the
UPPER position.
4.2.5 Turn the engine switch to the
ON
position.
4.2.6 Pull the starter handle lightly until resistance is felt, then pull it briskly. Do not allow the starter
handle to snap back against the engine. Return it gently to prevent damage to the starter.
4.2.7 If the choke lever was moved to the
CLOSED
position to start the engine, gradually move it to
the
OPEN
position as the engine warms up.
4.3 Setting Engine Speed
After starting the engine, move the throttle valve lever to the
UPPER
position for self-priming, and
check pump output.
Pump output is controlled by adjusting engine speed. Moving the throttle valve lever in the
UPPER
direction will increase pump output, and moving the throttle valve lever in the
LOWER
direction will
decrease pump output.
(Fig.9)
5.
TURN IT OFF
To stop the engine in an emergency, simply turn the engine switch to the
OFF
position. Under normal
conditions, use the following procedure.
5.1 Move the throttle valve lever to the
LOWER
position.
5.2 Turn the engine switch to the
OFF
position.
5.3 Turn the fuel cock to the
OFF
position.
After use, remove the water drain plug, and drain the pump chamber. Remove the water filler
cap, and flush the pump chamber with clean, fresh water. Allow the water to drain from the pump
chamber, then reinstall the water filler cap and water drain plug.