Transporting and Storing the Unit
CAUTION:
•
To avoid fire, allow water pump to cool down for at least twenty (20)
minutes before transporting or storing the unit.
•
Always transport and store the unit with the fuel cock in the “OFF”
position.
•
Always keep unit in horizontal position to the ground to prevent fuel
from spilling. Spilled gasoline and gasoline vapor may ignite.
•
Gasoline is extremely flammable and explosive.
Storing the Water Pump:
1.
Ensure the storage site for the unit is clean and dry.
2.
Clean the inside of the water pump.
a.
Operate water pump to intake fresh, clean water to wash inside of
unit.
b.
Remove Water Drain Plug and empty the water inside the unit
completely.
c.
Remove the Four Lock-‐down Bolts on Pump Housing.
d.
Remove front of Pump Housing.
e.
Thoroughly clean inside of unit.
f.
Reinstall front of Pump Housing.
g.
Reinstall and tighten Four Lock-‐down Bolts on Pump Housing.
h.
Reinstall the Water Drain Plug.
Before long term storage of your power equipment product, typically 30
days or more, perform the following:
3.
Set the fuel cock (valve) to the “OFF” position.
4.
Let the unit continue to run until it stops itself, burning all of the fuel in the fuel
system.
5.
Turn the ignition switch to the “OFF” position.
6.
Drain the engine oil in accordance with the “Oil Change Procedures” in this
Owner’s Manual’s Maintenance section. Do NOT re-‐fill with oil until ready to use
again.
7.
Remove the Spark Plug in accordance with the “Spark Plug Maintenance” in the
Owner’s Manual’s Maintenance section. Spray a lubricant, such as WD40®, into
the Spark Plug hole to lubricate the top of the piston and walls of the cylinder.
Replace the Spark Plug.
8.
Pull starter rope until resistance is felt. This will place the valves in the closed
position.