6. Electrical connection

• 

Ensure that the voltage supply and the 
current correspond to the information 
stated in the CE-plating and the 
information in these instructions.

• 

LIFA AirClean 3500 must be 

connected to a single-phase current 

(1~) 200-277 VAC (or 100-120 VAC), 
50/60 Hz, 10 A.

Only authorised electrician may do the 
repairs or installations of the electrical 

components. In addition, electrician has 
to be authorised by the manufacturer; 
otherwise the warranty expires. 

7. Noise level

The noise level of LIFA AirClean 3500 is 

low (<70 dB) and it does not depend on 

the operating environment. 

8. Transportation

Check all parts before installation and 

use. Ensure that none of them have 

been damaged during transport and the 

fan wheel rotates freely. The vacuuming 

unit must be protected from moisture 
and it must not be stored unprotected 
outside. Please be careful when lifting 

the vacuuming unit.

The following safety directions must be carefully observed in order to avoid 
injury of personnel or damage to the environment or the equipment.

Following these instructions will ensure the safe and uninterrupted use of 
the machine.

Safety Precautions 

• 

Equipment must not be used without a filter.

• 

This equipment must not be positioned nor used in the areas 

where there is a risk of explosion or hazardous substances are 

used.

• 

The equipment must not get wet and it must be protected 

from rain, vibration and wind.

• 

Foreign objects must not be inserted or fitted into the 

equipment.

• 

The machine must not be covered during the operation.

• 

The operator must ensure that the equipment is suitable and 

designed for the task and the statutory requirements are met.

Ensure that the power supply is 

reliably earthed/grounded!

1. Avoid contamination of the 

environment

The machine should be kept as 
clean as possible. The filters must 
be appropriately disposed of.

2. General safety

The power must be turned off when 
the machine is not being used. It is 

 

forbidden to make any modifications to 

LIFA AC3500. 

3. Operating safety

The person /persons performing the work 
should use personal protective equip

-

ment: filtered mouth mask, helmet, ear

-

muffs, goggles, overall, safety boots and 
other necessary protective equipment the 

project requires. The axial fan has 

 

extremely powerful suction. Items 
(clothing, hair etc.) could easily be 

sucked into the intake cone and cause 

injury. It is prohibited to remove 

 

protective grating of the suction inlet.  

The vacuuming unit must never be 

used with an unprotected suction inlet 

or exhaust outlet, because the fan 
wheel could cause serious injury. Any 
objects that get caught in the fan could 
be thrown out at high speed and cause 
injury. Always ensure the outlet air is 

directed to a safe place where there 
are no people or materials that could 

be damaged. Never put your hand in 

the vacuum. 

4. Workplace conditions

It is prohibited to use the vacuuming 
unit in handling of gases, which are 
classified as corrosive, toxic or explo

-

sive or contain high moisture. The  

machine must not be used in areas 
where there is a risk of explosion. The 
worksite must be free of obstacles and 

the main switch easily controlled.

5. Operating temperature

The temperature of the transferred 

gas must not exceed 80 °C (175 °F). 
The machine must not be used in an 

environment where the temperature 

exceeds 40 °C (100 °F) or drops below 
–20 °C (-4 °F).

4

Lifa airClean 3500  

5

Summary of Contents for AirClean 3500

Page 1: ...OPERATING AND MAINTENANCE MANUAL LIFA AirClean 3500 Electrically operated negative air pressure machine air cleaner...

Page 2: ...Conformity 14 LIFA Air Product Family 15 Congratulations on your new LIFA AirClean 3500 negative air machine LIFA AC3500 is designed for filtering cleaning of airborne pollutants such as construction...

Page 3: ...suitable and designed for the task and the statutory requirements are met Ensure that the power supply is reliably earthed grounded 1 Avoid contamination of the environment The machine should be kept...

Page 4: ...for and which are outlined in the instructions It is forbidden to use the equipment for any other purpose without written permission from the manufacturer If this equipment is used for a purpose other...

Page 5: ...IFA Air Third party repairs will void the warranty Installation Check that the exhaust air can flow unhindered and protect the unit from vibration or blows Ensure that the suction inlet and exhaust ou...

Page 6: ...information given in this plate 6420281010835 HEPA filter H13 size 450x450x292 mm 18 x18 x11 AC3500 37450450300 F7 bag filter 5 pockets plastic frame size 450x450x300 mm 18 x18 x12 AC3500 642028102292...

Page 7: ...tive from which machine has been bought or when agreed beforehand mutually in writing to the manufacturer postage paid to Oy Lifa Air Ltd Vellamonkatu 30 B FI 00550 Helsinki FINLAND Tel 358 9 3948 58...

Page 8: ...650 CFM 2500 1470 CFM 3600 2100 CFM 4600 2700 CFM HEPA 13 m3 h 700 410 CFM 1800 1100 CFM 2900 1700 CFM 3200 1880 CFM F7 bag filter m3 h 2400 1400 CFM 3200 1900 CFM 3500 2060 CFM Operating Voltage 200...

Page 9: ...58 sales lifa net www lifa air com These instructions should always be available for the personnel operating the machine Please read these instructions carefully before operating the machine Following...

Reviews: