6. Electrical connection
•
Ensure that the voltage supply and the
current correspond to the information
stated in the CE-plating and the
information in these instructions.
•
LIFA AirClean 3500 must be
connected to a single-phase current
(1~) 200-277 VAC (or 100-120 VAC),
50/60 Hz, 10 A.
Only authorised electrician may do the
repairs or installations of the electrical
components. In addition, electrician has
to be authorised by the manufacturer;
otherwise the warranty expires.
7. Noise level
The noise level of LIFA AirClean 3500 is
low (<70 dB) and it does not depend on
the operating environment.
8. Transportation
Check all parts before installation and
use. Ensure that none of them have
been damaged during transport and the
fan wheel rotates freely. The vacuuming
unit must be protected from moisture
and it must not be stored unprotected
outside. Please be careful when lifting
the vacuuming unit.
The following safety directions must be carefully observed in order to avoid
injury of personnel or damage to the environment or the equipment.
Following these instructions will ensure the safe and uninterrupted use of
the machine.
Safety Precautions
•
Equipment must not be used without a filter.
•
This equipment must not be positioned nor used in the areas
where there is a risk of explosion or hazardous substances are
used.
•
The equipment must not get wet and it must be protected
from rain, vibration and wind.
•
Foreign objects must not be inserted or fitted into the
equipment.
•
The machine must not be covered during the operation.
•
The operator must ensure that the equipment is suitable and
designed for the task and the statutory requirements are met.
Ensure that the power supply is
reliably earthed/grounded!
1. Avoid contamination of the
environment
The machine should be kept as
clean as possible. The filters must
be appropriately disposed of.
2. General safety
The power must be turned off when
the machine is not being used. It is
forbidden to make any modifications to
LIFA AC3500.
3. Operating safety
The person /persons performing the work
should use personal protective equip
-
ment: filtered mouth mask, helmet, ear
-
muffs, goggles, overall, safety boots and
other necessary protective equipment the
project requires. The axial fan has
extremely powerful suction. Items
(clothing, hair etc.) could easily be
sucked into the intake cone and cause
injury. It is prohibited to remove
protective grating of the suction inlet.
The vacuuming unit must never be
used with an unprotected suction inlet
or exhaust outlet, because the fan
wheel could cause serious injury. Any
objects that get caught in the fan could
be thrown out at high speed and cause
injury. Always ensure the outlet air is
directed to a safe place where there
are no people or materials that could
be damaged. Never put your hand in
the vacuum.
4. Workplace conditions
It is prohibited to use the vacuuming
unit in handling of gases, which are
classified as corrosive, toxic or explo
-
sive or contain high moisture. The
machine must not be used in areas
where there is a risk of explosion. The
worksite must be free of obstacles and
the main switch easily controlled.
5. Operating temperature
The temperature of the transferred
gas must not exceed 80 °C (175 °F).
The machine must not be used in an
environment where the temperature
exceeds 40 °C (100 °F) or drops below
–20 °C (-4 °F).
4
Lifa airClean 3500
5