You  can  use  MultiLink™ Software  to  allow  your  UPS  to  communicate  to
your  computer  via  your  DB-9  communications  port.  A MultiLink  Software  CD  is
included in the box, or you can download it from our web site at www.liebert.com. 

The PowerSure™ Personal XT UPS contains a standard DB-9 receptacle located
on  the  rear  of  the  UPS  unit.    Several  signals  are  provided  on  this  port  and  are
assigned as follows:

PIN

ASSIGNMENT DESCRIPTION

1

Low Battery (open collector)

2

No connection

3No connection
4

Remote Shutdown (5-12V); on battery operation

5

Common

6

Remote Shutdown (short to pin5); any mode operation

7

Low Battery (open emitter)

8

AC Fail (open emitter) 

9

AC Fail (open collector)

The DB-9 communication port allows:

·

the status of UPS to be monitored,

·

data to be backed up,

·

computer to be switched off

COMMUNICATIONS

The PowerSure Personal XT UPS requires very little maintenance. The batteries
are  valve  regulated,  nonspillable,  lead  acid,  and  require  that  they  be  kept
charged  to  obtain  their  designed  life.    When  connected  to  the  mains  supply,  the
battery is continuously charged.

When  storing  the  UPS  for  any  length  of  time,  it  is  recommended  to  plug  in  the
UPS for at least 24 hours every four to six months to ensure full recharge of the
batteries.

Battery  disposal  -  When  the  battery  life  is  expended  (see  alarm  indications),
dispose of the discarded batteries in accordance with local environmental laws.

MAINTENANCE

1

2 3

4

5

6

7 8 9

PIN Assigment

Summary of Contents for PowerSure Personal XT 1250 VA

Page 1: ...450 700 1250 VA 230V PowerSureTM Personal XT USER MANUAL English Deutsch Fran ais Italiano Espa ol...

Page 2: ...OR OTHER APPLICATIONS Store in safe place if not required at this time 4 This UPS must be earthed at all times during operation Connect only to a mains supply socket outlet with an earth connection A...

Page 3: ...stable cart stand or table Do not place UPS under direct sunlight or close to heat emitting sources Do not place UPS power cord in any area where it may get damaged by heavy objects Follow all warning...

Page 4: ...ovides conditioned power to microcomputers and other sensitive electronic equipment PowerSure OUTPUT Lead acid battery inside the enclosure Blei Akkumulator innerhalb des Gehause INPUT FUSE 250V 5A T...

Page 5: ...0V 50 60Hz 4 0A 1 OUTPUT 230V 50 60Hz 700VA 420W 3 1A MADE IN CHINA Remove from Box Remove Plug from Units and replace in UPS Press ON Button Plug Units s into UPS 110 mm 0 40 C Check for Damage OUTPU...

Page 6: ...EDs of the front panel will light up for 2 seconds The green light up continuously This indicates normal operation Note If the UPS continues to beeps or the green light is not alight even mains power...

Page 7: ...c 1 beep every 4 sec Power failure UPS is battery mode 1 beep every sec Battery low UPS is in battery mode batteries are nearly axhausted and UPS will be shut down 1 beep every 2 sec Battery weak UPS...

Page 8: ...n Power cord defective Please contact your dealer Plug the UPS into a working wall outlet for at least Grenn LED blinks very low battery voltage 8 hours to recharge the batteries If the problem red LE...

Page 9: ...itter 8 AC Fail open emitter 9 AC Fail open collector The DB 9 communication port allows the status of UPS to be monitored data to be backed up computer to be switched off COMMUNICATIONS The PowerSure...

Page 10: ...20 load 20s to shutdown Battery mode 120 load 5s to shutdown BATTERY PARAMETERS Model Number PSPXT450 230 PSPXT700 230 PSPXT1250 230 Type Valve regulated nonspillable lead acid Quantity x Voltage x 1...

Page 11: ...ident abuse neglect negligence unauthorized modification alteration or repair use beyond rated capacity or improper installation maintenance application or use including without limitation use in a ma...

Page 12: ...han 1000 kVA Integrated systems that provide both environmental and power protection in a single flexible package Monitoring and control on site or remote from systems of any size or location Service...

Reviews: