Liebert PS UPS                                                                              Installation and User 
Manual 
 

 

Page 

 

V2.6 

Emerson Network Power 

Liebert PS UPS

 

User Manual 

 

Version: V2.6 

Revision date: 

May 2006 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Emerson Network Power provides customers with technical support. Users may contact the nearest 

Emerson local sales office or service center. 

 

While every precaution has been taken to ensure accuracy and completeness in this manual, 

Emerson Network Power assumes no responsibility and disclaims all liability for damages resulting 

from use of this information or for any errors or omissions. 

 

Emerson Network Power pursues a policy of continuous product development and reserves the 

right to change the equipment design without notice. 

 

Copyright © 2005 by Emerson Network Power 

All rights reserved. The contents in this document are subject to change without notice 

Summary of Contents for Liebert PS

Page 1: ...Liebert PS UPS User Manual Power Protection for Business Critical Continuity...

Page 2: ...ion has been taken to ensure accuracy and completeness in this manual Emerson Network Power assumes no responsibility and disclaims all liability for damages resulting from use of this information or...

Page 3: ...he manual should be read prior to commencing the installation Do not connect appliances or equipment e g laser printer to the output socket which would overload the UPS system Place cables in such a w...

Page 4: ...d to the battery and are still electrically live and dangerous Before carrying out any kind of servicing and or maintenance disconnect the batteries and verify that no current is present and no hazard...

Page 5: ...age 2 V2 6 Emerson Network Power 1 System Description 1a Front panel 1 Power Switch 2 UPS status Indicator AC Mode Green lighting Battery Mode Green flashing 3 Fault LED Red flashing 1b Back Panel 1 O...

Page 6: ...arged however some charge may be lost during shipping and the battery should be recharged prior to use Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it pl...

Page 7: ...d the beeper is off after it performs a self diagnosis the beeper and the red and green indicator lights are on for several seconds At this time user may turn on the PC and other loads Press the switc...

Page 8: ...ery No LED display on the front panel 3 Power switch is not pressed 3 Press power switch again 1 Overload of the UPS 1 Remove some noncritical load 2 Battery voltage is too low 2 Charge battery 8 hour...

Page 9: ...e Low Battery at Battery Mode Fault Battery Weak at AC Mode Battery Fault at AC Mode PROTECTION Full Protection Dimension DXWXH mm Net Weight kgs 2 5 3 1 Operating Environment Noise Level Discharge ov...

Page 10: ...32924 Emerson Network Power Korea 8th Fl HongIk University KangNam Art Center 51 12 Banpo Dong Seocho Gu Seoul 137 044 Korea T 82 2 34831500 F 82 2 5927883 Emerson Network Power Malaysia Sdn Bhd Wisma...