background image

Ensuring The High Availability 
0f Mission-Critical Data And Applications. 

While every precaution has been taken to ensure the accuracy and completeness of this literature, Liebert Corporation assumes  
no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 
© 2006 Liebert Corporation 
All rights reserved throughout the world.  
Specifications subject to change without notice. 
® Liebert and the Liebert logo are registered trademarks of Liebert Corporation. All names referred to are trademarks or  
registered trademarks of their respective owners. 

Locations 

United States 

1050 Dearborn Drive 

P.O. Box 29186 

Columbus, OH 43229 

Europe 

Via Leonardo Da Vinci 8 

Zona Industriale Tognana 

35028 Piove Di Sacco (PD) Italy 

+39 049 9719 111 

Fax: +39 049 5841 257 

Asia 

7/F, Dah Sing Financial Centre 

108 Gloucester Road, Wanchai 

Hong Kong 

852 2572220 

Fax: 852 28029250 

The global leader in enabling Business-Critical Continuity

Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are 
trademarks and service marks of Emerson Electric Co. 

©2006 Emerson Electric Co. 

AC Power Systems 

Connectivity 

DC Power Systems 

Integrated Cabinet Solutions 

Embedded Computing 

Embedded Power 

Power Switching & Control 

Precision Cooling 

Outside Plant 

EmersonNetworkPower.com 

Services 

Site Monitoring 

Surge Protection 

Technical Support / Service 

Web Site 

www.liebert.com 

Monitoring 

800-222-5877 
[email protected] 
Outside the US: 614-841-6755 

Single-Phase UPS 

800-222-5877 
[email protected] 
Outside the US: 614-841-6755 

Three-Phase UPS 

800-543-2378 
[email protected] 

Environmental Systems 

800-543-2778 
Outside the United States 
614-888-0246 

Emerson Network Power.

  

SL-16610_REV2_08-06

Summary of Contents for Air Flow Enhander XDA

Page 1: ...Precision Cooling For Business Critical Continuity Liebert XDA Air Flow Enhancer User Manual...

Page 2: ......

Page 3: ...he Rear Cabinet Door 3 2 3 1 Prepare to Install the Unit 3 2 3 2 Mount the Unit and Attach it to the Cabinet 4 2 4 Mounting the XDA on the Interior of the Rear Cabinet Door 5 2 4 1 Prepare to Install...

Page 4: ...ii...

Page 5: ...mproves extraction of heat from high heat density equipment cabinets Permanently attached dual power cords to prevent accidental disconnection and increase up time Hot Installable No shutdown or remov...

Page 6: ...ify that the XDA unit voltage matches the available utility power The nameplate with this information is located on the top of the unit Note the XDA s appearance the front of the unit bears the Lie be...

Page 7: ...ounting height 3 Position the hanging support of the bracket toward the rear of the unit with the tabs of the bracket down and in front of the mounting angles 4 From the rear of the unit place screws...

Page 8: ...oes not interfere with operation of the door latch 3 Place screws through the middle and lower mounting holes of the XDA mounting angle and then through the door Place nuts on the screws and tighten t...

Page 9: ...screws removed in Step 1 above 5 Determine the desired mounting position on the door Place the bracket on the top of the door with the tabs on the outside The mounting bracket will be used to deter m...

Page 10: ...to minimize bypass air and maximize heat removal from the equip ment cabinet 1 Ensure that the cable openings in the raised floor beneath the cab inet are properly sealed Cool air from precision air...

Page 11: ...nded Ensure adequate length of the power cords when the door is fully opened Secure the power cords using the cable ties provided 3 1 Routing the Power Cords Through the Door Optional The power cords...

Page 12: ...f a power failure should occur on the primary power source the XDA will operate from the secondary source until the primary power source is restored The XDA will continue to operate as long as either...

Page 13: ...ICATIONS Nominal Capacity 1000 CFM 60Hz Dimensions W x D x H in mm 8 x 2 25 x 56 203 2 x 57 2 x 1422 4 Weight lbs kg 25 11 3 Electrical Specifications 120V 1 50 60Hz 230V 1 50 60Hz Amp Draw 1 5 A 120V...

Page 14: ...10...

Page 15: ......

Page 16: ...ax 39 049 5841 257 Asia 7 F Dah Sing Financial Centre 108 Gloucester Road Wanchai Hong Kong 852 2572220 Fax 852 28029250 The global leader in enabling Business Critical Continuity Business Critical Co...

Reviews: