All electrical connections should be installed by a qualifi ed 
(licensed) electrician only.  All wiring must comply with the 
National Electrical Code (NEC) and applicable local codes.

VERIFY THAT ALL POWER CIRCUITS ARE 

DE-ENERGIZED AND LOCKED OUT BEFORE 

MAKING ELECTRICAL CONNECTIONS.

Voltage Ratings and Power Source Confi gurations

Before making connections to the unit, verify that the unit 
model number and nameplate voltage rating are appropriate 
for connection to the intended power source. See the chart 
on page 4 for voltage rating applications with typical power 
source confi gurations.

Parallel Connection 

(see Figures on page 5)

To reduce the wiring impedance to surge currents, it is 
recommended that the phase, neutral (if required), and ground 
conductors are twisted together and routed in the same 
raceway (conduit). Avoid any sharp bends in the conductors.

Wire Sizing —

 With parallel connection, the size of the 

wiring to the SPD unit is independent of the protected 
circuit’s ampacity. For suggested wire size refer to individual 
product sheet.

NEC Article 285-21(B) requires surge suppressor connecting 
conductors to be at least #14 copper or #12 aluminum.

Overcurrent Protection —

 The SPD unit conducts practically 

no current under normal operation and only conducts very 
short duration transient surge currents. 

The following is from the National Electric Code 2002 Edition.

285.21 Connection.

 Where a TVSS is installed, it shall be 

connected as follows:

(A) Location.

(1)  

Service Supplied Building or Structure.

 The transient 

voltage surge suppressor shall be connected on the 
load side of a service disconnect overcurrent device 
required in 230.91.

(2)  

Feeder Supplied Building or Structure.

 The transient 

voltage surge suppressor shall be connected on the 
load side of the fi rst overcurrent device at the building 
or structure.

Exception to (1) and (2): Where the TVSS is also listed as a surge 
arrestor, the connection shall be as permitted by Article 280.

(3)  

Separately Derived System.

 The TVSS shall be 

connected on the load side of the fi rst  overcurrent 
device in a separately derived system.

Disconnect Switch (If Provided) —

 All SPD units must still be 

connected to the load side of the main service disconnect, or 
load side of a protected circuit’s disconnecting means.

Surge Voltage Ratings —

 To obtain the suppression voltage 

ratings (SVRs), as obtained by Underwriters Laboratory, 
Incorporated, in accordance with the Standard for Safety, 
Transient Voltage Surge Suppressors (TVSS), Standard 1449, 
Second Edition, dated August 15, 1996, marked on this 
product, the wire size listed for each product must be utilized 
to connect the unit to your facilities’ power grid. Connections 
made with conductors other than the wire size listed may 
result in different SVRs.

Circuit Ampacity Limitations —

 Representative samples 

of these products have been investigated by Underwriters 
Laboratories, Incorporated to withstand, without exposing 
live circuits or components at system voltages and fault 
currents ranging from 14,000 AIC up to 200,000 AIC, as 
described in the Standard for Safety, Transient Voltage Surge 
Suppressor (TVSS), Standard 1449, Second Edition, dated 
August 15, 1996. Verify each products fault current rating on 
the individual installation pages that follow.

Surge Suppression Systems

Installation, Operation and Maintenance Manual 

Liebert TVSS  Units SL-22085 Rev 2, 11/2006

ELECTRICAL CONNECTIONS

EQUIPMENT PERFORMANCE!!

For maximum system performance, the unit must be 
located as close to the protected circuit as practical 
to minimize interconnecting wiring length.

Installation, Operation and Maintenance Manual 

26 

Liebert TVSS  Units SL-22085 Rev 2, 11/2006

Items Not Covered By Warranty:

THIS WARRANTY DOES NOT COVER DAMAGE OR DEFECT CAUSED BY misuse, improper application, wrong or inadequate electrical current or 
connection, negligence, inappropriate on site operating conditions, corrosive atmosphere, repair by non-Liebert designated personnel, accident 
in transit, tampering, alterations, a change in location or operating use, exposure to the elements, Acts of God, theft or installation contrary to 
Liebert’s recommendations or specifi cations, or in any event if the Liebert serial number has been altered, defaced or removed.  Notwithstanding 
the foregoing, the following Acts of God are covered:  lightning-induced surges, which are transients, spikes or other sub-cycle, discontinuous 
events impinging on normally applied voltage as defi ned by reference data in the latest version of IEEE C62.41 and the Liebert product performance 
specifi cations.

THIS WARRANTY DOES NOT COVER shipping costs, installation costs, circuit breaker resetting or maintenance or service items and further, except 
as provided herein, does NOT include labor costs or transportation charges arising from the replacement of the Liebert product or any part thereof 
or charges to remove or reinstall same at any premises of the User.

THIS WARRANTY DOES NOT COVER DAMAGE OR DEFECT CAUSED BY use of the Liebert product in combination with any electrical or electronic 
components, circuits, systems, assemblies, or other materials not furnished by Liebert. Liebert does NOT warrant the suitability for use or the 
results of the Liebert product in combination with the products of others.

THE PRODUCTS LISTED IN THIS WARRANTY ARE NOT DESIGNED FOR USE IN THE FOLLOWING APPLICATIONS: (i) ANY NUCLEAR OR RELATED 
APPLICATIONS; AND (ii) LIFE SUPPORT AND PATIENT-CONNECTED AND APPLIED MEDICAL AND DENTAL APPLICATIONS.

REPAIR OR REPLACEMENT OF A DEFECTIVE PRODUCT OR PART THEREOF DOES NOT EXTEND THE ORIGINAL WARRANTY PERIOD.

Limitations:

•  THIS WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS 

FOR A PARTICULAR PURPOSE. 

• USER’S SOLE AND EXCLUSIVE REMEDY IS REPAIR OR REPLACEMENT OF THE LIEBERT PRODUCT AS SET FORTH HEREIN.

•  IF USER’S REMEDY IS DEEMED TO FAIL OF ITS ESSENTIAL PURPOSE BY A COURT OF COMPETENT JURISDICTION, LIEBERT’S RESPONSIBILITY FOR 

PROPERTY LOSS OR DAMAGE SHALL NOT EXCEED THE NET PRODUCT PURCHASE PRICE.

•  IN NO EVENT SHALL LIEBERT ASSUME ANY LIABILITY FOR INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OF ANY KIND 

WHATSOEVER, INCLUDING WITHOUT LIMITATION, LOST PROFITS, BUSINESS INTERRUPTION OR LOSS OF DATA, WHETHER ANY CLAIM IS BASED 
UPON THEORIES OF CONTRACT, NEGLIGENCE, STRICT LIABILITY, TORT OR OTHERWISE.

Miscellaneous:

•  NO SALESPERSON, EMPLOYEE OR AGENT OF LIEBERT IS AUTHORIZED TO ADD TO OR VARY THE TERMS OF THIS WARRANTY. Warranty terms may 

be modifi ed, if at all, only in a writing signed by a Liebert offi cer.

•  Liebert obligations under this warranty are conditioned upon Liebert timely receipt of full payment of the product purchase price and any other 

amounts due. Liebert reserves the right to supplement or change the terms of this Warranty in any subsequent warranty offering to User or 
others.

•  In the event that any provision of this Warranty should be or becomes invalid and/or unenforceable during the warranty period, the remaining 

terms and provisions shall continue in full force and effect.

•  This Warranty shall be governed by, and construed under, the laws of the State of Ohio, without reference to the confl ict of laws principles 

thereof.

•  This Warranty represents the entire agreement between Liebert and User with respect to the subject matter herein and supersedes all prior or 

contemporaneous oral or written communications, representations, understandings or agreements relating to this subject.

Liebert Interceptor II Printer S5   5

12/29/06   1:37:55 PM

Summary of Contents for AccuVar

Page 1: ...rid Advantage Type SS LM AccuVar PowerSure LPM LPL Series ATF Series PanelGuard Extension AccuGuide Products Installation Operation and Maintenance Manual Surge Protection For Business Critical Continuity 12 29 06 1 37 52 PM ...

Page 2: ...12 29 06 1 37 53 PM ...

Page 3: ...ing 6 SPD Monitoring 6 TROUBLESHOOTING SERVICING MAINTENANCE 7 Troubleshooting 7 Servicing 7 Corrective Maintenance 7 Preventative Maintenance Inspection and Cleaning 7 PRODUCT INSTALLATIONS 8 Typical Parallel Installation Type SI H SS LM ACV AII LPM LPL 8 Active Tracking Filter Type F Series 10 PanelGuard Series Type LPGE Series 12 AccuGuide Series Type ACG 13 DIMENSIONAL INFORMATION 15 Intercept...

Page 4: ... designed for operation indoors in ambient temperatures of 40ºC 40ºF to 60ºC 140ºF with a relative humidity of 0 to 95 non condensing The unit is provided in an industrial use enclosure which is dust tight and drip tight and should not be installed in areas with excessive dust corrosive vapors flammable materials or explosive atmospheres Audible Noise The audible noise of the unit is less than 40 d...

Page 5: ...e The transient voltage surge suppressor shall be connected on the load side of the first overcurrent device at the building or structure Exceptionto 1 and 2 WheretheTVSSisalsolistedasasurge arrestor the connection shall be as permitted by Article 280 3 Separately Derived System The TVSS shall be connected on the load side of the first overcurrent device in a separately derived system Disconnect Swi...

Page 6: ...20 L N 240S 240 277 240 277 480 130 L L 150 L L 275 L L 275 L L 420 L L 208L or 208 240L or 240 400L or 400 480L or 480 600L or 600 N A 208 208 N A 240 240 N A 400 400 N A 480 480 N A 600 600 Note 1 For other voltages or source confi gurations consult factory 150 L N 150 L N 320 L N 320 L N 320 L N 320 L N 420 L N 120Y 127Y 230Y 230Y 254Y 277Y 347Y 120 120 208 127 127 220 220 220 380 230 230 400 25...

Page 7: ...otary Disconnect To Protected Loads Liebert Surge Protective Device Protected Panel Wireshouldbe lessthan5feet andstraight aspossible Neutral Phase s Transient Ground Safety Ground Neutral Phases Ground To Protected Loads Liebert Surge Protective Device Protected Panel Wireshouldbe lessthan5feet andstraight aspossible Neutral Phase s Transient Ground Safety Ground Neutral Phases Ground Rotary Disc...

Page 8: ...TION THE NEUTRAL IF PROVIDED MUST BE RELIABLY CONNECTED TO THE NEUTRAL OF THE SOURCE FAILURE TO PROVIDE A RELIABLE NEUTRAL CONNECTION MAY RESULT IN MODULE FAILURE SPD Monitoring External Status Indicators These indicators provide a summary of the status of the surge SPD module For normal conditions the green OK LED is illuminated and the red Service LED is extinguished If the surge SPD module requ...

Page 9: ...assistance contact your local Liebert Sales Representative or Liebert at 800 288 6169 or 607 724 2484 Corrective Maintenance TheLiebertSPDisdesignedforyearsoftrouble freeoperation However even the most reliable equipment may fail under abnormal conditions Diagnostic indicators are provided to indicate when the unit needs replacement see individual SPD operation of this manual for details To ensure...

Page 10: ...ional Enclosures SPD Standard Enclosure Optional Enclosures Type SI NEMA 4 NEMA 4X Type ACV AII NEMA 4X N A Type H NEMA 12 NEMA 3R 4 4X Type LPM NEMA 12 NEMA 3R 4 4X Type SS NEMA 4X N A Type LPL ABS Plastic 94V 0 NEMA 1 Type LM NEMA 12 NEMA 3R 4 4X 3 Determine where the SPD is to be mounted allowing for minimum length of wire between itself and the input power terminals of the service panel Punch ...

Page 11: ...nnections see page 15 7 Apply power The surge protector is fully operational when the GREEN LEDs on the modules and the front door of enclosure are illuminated If the GREEN LEDs are extinguished or a RED LED is illuminated check to ensure that power is applied to the SPD If an abnormal indication is present remove power to the SPD and contact Liebert Emerson Network Power Surge Protection at 1 800...

Page 12: ...nput to output coupling of noise and transients Do not route input and output wiring in the same raceway If practical terminate input and output raceways conduits at opposite ends of the active tracking filter enclosure input near the top and output near the bottom 7 The Liebert Active Tracking Filter System is wired in line in series with the protected load s See Figures on the following page 8 Te...

Page 13: ... WIRE SIZE RANGE FILTER CONTINUOUS PHASE AND TRANSIENT SAFETY CURRENT RATING NEUTRAL TERMINALS GROUND TERMINAL GROUND TERMINAL 30 100 A 14 2 0 1 14 2 0 5 14 4 4 225 A 6 250 kcmil 1 14 2 0 5 10 1 0 4 400 A 6 250 kcmil 2 6 250 kcmil 2 6 250 kcmil 4 800 A 2 75 x 50 Cu Busbar 3 6 250 kcmil 2 6 250 kcmil 4 1200 A 2x 6 0 x 25 Cu Busbar 3 6 250 kcmil 2 6 250 kcmil 4 2000 A 3x 6 0 x 25 Cu Busbar 3 6 250 k...

Page 14: ...oltage Surge Suppressor TVSS Standard 1449 Second Edition dated August 15 1996 7 Anexternalcircuitbreakerisnotnecessaryforover currentprotection However itisrecommendedthattheSPDbeconnected in series with a 30A circuit breaker The SPD shall be connected in accordance with all national and local electrical codes 8 To obtain the suppression voltage ratings SVRs as obtained by Underwriters Laboratory...

Page 15: ...ating of the device supplied by the tap conductors or not less than the rating of the over current protective device at the termination of the tap conductors 2 The tap conductors do not extend beyond the switchboard panelboard disconnecting means or control devices they supply 3 Except at the point of connection to the feeder the tap conductors are enclosed in a raceway which shall extend from the...

Page 16: ...close to the protected bus as possible This product was designed to address those instances when a close installation is not possible However while the voltage drop experienced with an AccuGuide assembly is significantly reduced care should be taken to keep connection lengths to a minimum Each end of the AccuGuide assembly is shipped with five foot pigtails The length is offered as a worst case need...

Page 17: ...ions Inches Weight lbs Suggested Breaker Size Suggested Wire Size AWG Allowable Breaker Range Allowable Wire Range Dimensions Inches Unit Weight lbs Suggested Breaker Size Suggested Wire Size AWG Allowable Breaker Range Allowable Wire Range A B C D E F A B C D E F SI016 SI025 SI032 SI040 SI050 SI060 SI075 SI100 16 20 20 20 12 16 16 20 8 8 8 8 17 25 17 25 21 25 21 25 9 5 10 10 14 0 44 0 44 0 44 0 4...

Page 18: ...1 2006 Surge Suppression Systems Hybrid Advantage Series Type H AccuVar Series Type ACV AII E F 4X B A D C 1 840 Max 2 625 Max Service Panel for Loads to be Protected Phase L1 A Phase L2 B Phase L3 C Disconnect Main Breaker for Panel Neutral Buss Ground Buss Dedicated Disconnect Optional Recommended Wire Entrance 6 875 7 375 0 212 8 125 3 088 4 125 4 750 Slots Will Accept 8 32 Screws 1 2 Flexible ...

Page 19: ... 4 FxxxD60 Three Phase Delta 24 0 20 0 9 0 25 25 14 0 44 50 22 7 FxxxY60 Three Phase Wye 24 0 20 0 9 0 25 25 14 0 44 60 27 2 FxxxN L100 Single Phase 30 0 24 0 9 0 25 25 14 0 44 60 27 2 FxxxS100 Split Phase 30 0 24 0 9 0 31 25 18 0 44 70 31 8 FxxxD100 Three Phase Delta 30 0 24 0 9 0 31 25 18 0 44 70 31 8 FxxxY100 Three Phase Wye 30 0 24 0 9 0 31 25 18 0 44 80 36 3 FxxxN L225 Single Phase L N 30 0 2...

Page 20: ...Panel For Loads to be Protected Disconnect Main Breaker For Panel Dedicated Disconnect Optional Neutral Buss Ground Buss Phase A Phase B Phase C Polycarbonate Window B A C E F D Type SS Series Unit Dimensions Inches Weight lbs Suggested Breaker Size Suggested Wire Size AWG Allowable Breaker Range Allowable Wire Range A B C D E F 1 Phase 3 Phase 13 32 17 32 6 6 9 6 14 75 18 75 10 12 0 32 0 32 26 43...

Page 21: ...sted Wire Size AWG Allowable Breaker Range Allowable Wire Range A B C D E F LM060 LM080 LM100 LM125 LM150 LM200 LM225 LM250 14 14 16 8 8 9 16 75 16 75 21 25 12 12 10 0 31 0 31 0 44 32 41 56 40 A 40 A 100 A 8 8 2 15A 100A 14 2 16 16 20 LM Series with Rotary Disconnect Unit Dimensions Inches Weight lbs Suggested Breaker Size Suggested Wire Size AWG Allowable Breaker Range Allowable Wire Range A B C ...

Page 22: ...anel for Loads to be Protected Phase L1 A Phase L2 B Phase L3 C Disconnect Main Breaker for Panel Neutral Buss Ground Buss Dedicated Disconnect Optional Unit is supplied from the factory with a minimum length of 18 of 12 wire for connection It is recommended that a 30A circuit breaker be used for installation Unit is equipped with Summary Alarm Contacts The 18 wires are designated as follows YELLO...

Page 23: ...r Loads to be Protected Phase L1 A Phase L2 B Phase L3 C Disconnect Main Breaker for Panel Neutral Buss Ground Buss Dedicated Disconnect Unit is equipped with Summary Alarm Contacts The 18 wires are designated as follows YELLOW Normally Open ORANGE COMMON BLUE Normally Closed Unit is supplied from the factory with a minimum length of 18 of 12 wire for connection It is REQUIRED that a 30A circuit b...

Page 24: ...PanelGuard Series Type LPGE Customer Supplied PanelBoard Neutral Bar Uninsulated Ground Bar Conduit Collar Conduit Collar Slots for Sliding Trim To Ensure Proper Fit Liebert Supplied LPGE Unit 3 Pole 30 Amp Circuit Breaker Summary Alarm Contacts Inside Module Remove Cover for Access Liebert Interceptor II Printer S9 9 ...

Page 25: ...Surge Suppression Systems Installation Operation and Maintenance Manual 23 Liebert TVSS Units SL 22085 Rev 2 11 2006 Example Installations 12 29 06 1 37 57 PM ...

Page 26: ...Installation Operation and Maintenance Manual 24 Liebert TVSS Units SL 22085 Rev 2 11 2006 Surge Suppression Systems Liebert Interceptor II Printer S7 7 ...

Page 27: ...Liebert s final invoices and to applicable Liebert product brochures and manuals current as of the date of product shipment Descriptions Liebert does not control the installation and use of any Liebert product Accordingly it is understood that the Descriptions are NOT WARRANTIES OF PERFORMANCE and NOT WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE Obtaining Performance Under This Warranty Within a ...

Page 28: ...D APPLIED MEDICAL AND DENTAL APPLICATIONS REPAIR OR REPLACEMENT OF A DEFECTIVE PRODUCT OR PART THEREOF DOES NOT EXTEND THE ORIGINAL WARRANTY PERIOD Limitations THIS WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE USER S SOLE AND EXCLUSIVE REMEDY IS REPAIR OR REPLACEMENT OF THE LIEBERT PRODUCT AS SET FORTH HE...

Page 29: ...Surge Suppression Systems Installation Operation and Maintenance Manual 27 Liebert TVSS Units SL 22085 Rev 2 11 2006 Limited Warranty 12 29 06 1 37 54 PM ...

Page 30: ...Installation Operation and Maintenance Manual 28 Liebert TVSS Units SL 22085 Rev 2 11 2006 Items Not Covered By Warranty Liebert Interceptor II Printer S3 3 ...

Page 31: ...e 852 28029250 FAX Liebert com Technical Support 607 724 2484 Phone 607 722 8713 FAX 800 288 6169 Toll Free While every precaution has been taken to ensure the accuracy and completeness of this literature Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions 2006 Liebert Corporation All rights res...

Reviews: