10.0
ALARM FUNCTION
In order to avoid any counting error, this scale has been incorporated with the
alarm function setting to inform operator when there is counting error in case of
lack of sample number or lack of sample weight. In addition, user can also set the
upper limit and lower limit for sample count to indicate whether the total piece
count quantity has reached the desired quantity.
10.1
Lack of sample alarm
This alarm function will be activated when the total weight of sample is below
the limit value for accurate counting to perform.
In order to rectify this error message, follow these steps;
a)
Place more sample on the weighing platter.
b)
Press the numerical (0-9) key to insert the new number of samples on the weighing
platter and press [WT/SET] to confirm the weight.
c)
Repeat step (a) and (b) until the ‘lack of sample’ sign disappear.
10.2
: Lack of piece weight alarm
This alarm function will be activated when the average unit weight or set weight
is insufficient for accurate counting operation.