Liberty Pumps Omnivore XLSG Series Installation Manual Download Page 5

6850000C

Copyright © Liberty Pumps, Inc. 2020 All rights reserved.

5 | EN

Uninstalled

 pumps that are idle for greater than three months 

should have impellers and cutters manually rotated once a month 

to lubricate the seals.

Installed

 pumps that are idle for greater than one month should 

have impellers and cutters manually operated through the breaker 

panel once a month to lubricate the seals.

Pump Design

XLSG/XLSGX-Series grinder pumps are designed for continuous 

underwater operation. The motor and pump form a close coupled, 

watertight unit. The induction motor is insulated against heat and 

moisture in accordance with Class F 311°F (155°C) regulations.
The motor is protected against damage from water entry by two 

mechanical seals. The lower seal is 2-piece, silicon carbide/silicon 

carbide and the upper seal is unitized silicon carbide/silicon 

carbide.
The impeller and volute are designed for efficient flow 

characteristics and clog-free operation. The hardened cutters 

grind solids and fibrous matter into small particles that can be 

safely pumped through small diameter piping.

Pump System Components

 Control Panel

 

Float switches must be connected to an intrinsically safe 

circuit in the control panel as per the requirements of 

Chapter 5 of the National Electric Code®.

 

XLSG/XLSGX-Series grinder pumps require a separate, approved 

control panel for automatic operation. Operation will be 

according to the control selected. Refer to separate 

manufacturer’s instructions supplied with the unit.
The control panel shall be installed outside the hazardous area 

and appropriately isolated and sealed to prevent any potential 

ignition or explosion. Only approved controls that have 

intrinsically safe float switch connections shall be used. Mounting, 

installation and wiring connections are specific to the control 

panel used. Refer to the manufacturer’s instructions supplied with 

the unit. 

IMPORTANT: 

When connecting an XLSG/XLSGX-Series pump to 

an existing control panel, verify the panel is correctly sized and 

equipped for the pump.
The control panel for 3-phase pumps shall have provisions for the 

thermostats that open the motor contactors in order to maintain 

the T4 (135°C) temperature class. Do not exceed voltage/current 

combinations for the thermostat: 16 VDC/20 Amps, 115 VAC/

22 Amps, 277 VAC/8 Amps, 600 VAC/4 Amps. All models have a 

temperature (T) class rating of T4 with thermostats connected. 

Failure to use the proper circuitry and to connect the thermostat 

will void the T4 temperature class of the pump and will drop the 

temperature class to T3 (200°C).
Intrinsically safe control panels designed for use with the XLSG/

XLSGX-Series pumps available from Liberty Pumps can be found 

at http://www.LibertyPumps.com/Portals/0/Files/

panel_selection_guide.pdf or contact Liberty Pumps.

1-phase pumps require a panel-mounted start circuit consisting of 

a start capacitor, run capacitor, and start relay, which are available 

separately. Refer to Table 1 for these control panel components.

 Overload Protection

XLSG/XLSGX-Series grinder pumps require overload protection in 

the control panel. The motor control unit shall be approved and 

shall be properly sized or adjusted for the full load input power 

indicated on the pump nameplate. It is important to properly 

adjust or select the motor control overload protection. The full 

load amps on the nameplate should be used as a baseline, but it is 

important to consider that events such as supply voltage variation 

or large solids passing through the pump can temporarily increase 

current draw. To avoid possible nuisance tripping, it may be 

necessary to adjust overloads to a value slightly higher than the 

full load input power indicated on the pump nameplate.

 Thermostats

XLSG/XLSGX-Series grinder pumps are protected from 

overheating by means of thermal switches (thermostat) located in 

the motors. For 1-phase models, a hermetically sealed thermal 

overload device is mounted on the motor windings and wired 

directly in series with the motor’s winding, interrupting power in a 

high heat condition. 3-phase models utilize two thermostats 

mounted in series directly on the motor windings. The thermostat 

circuit shall be connected to a control panel that will stop power 

to the pump in a high temperature condition.
Both 1- and 3-phase pumps are constructed with class F materials, 

with a maximum operation temperature of 155°C. 

Failure to use 

the proper circuitry and connection of the thermostat will drop 

temperature class from T4 to T3 on 3-phase units

.

Many panels have a manual reset button for the thermostats on 

3-phase units. This button must be pressed to reset the system 

after the pump has cooled. 1-phase units reset automatically after 

the pump has cooled.

RISK OF SERIOUS INJURY OR DEATH

Table 1. Control Panel Components 1-Phase 

Required Component and Specification

Liberty Pumps

P/N

208 V 1-phase Start Kit

(contains 3 items listed separately below)

K001640

Start Capacitor, 270–324 µF 220/250 VAC
Run Capacitor, 65 µF 370 VAC
Start Relay
230 V 1-phase Start Kit

(contains 3 items listed separately below)

K001641

Start Capacitor, 270–324 µF 220/250 VAC
Run Capacitor, 50 µF 370 VAC
Start Relay

Summary of Contents for Omnivore XLSG Series

Page 1: ...placement manual visit LibertyPumps com or contact Liberty Pumps at 800 543 2550 Retain dated sales receipt for warranty Model 7000 Apple Tree Avenue Bergen NY 14416 ph 800 543 2550 fax 585 494 1839 w...

Page 2: ...by its power cord This will damage the power cord and could expose the electrically live wires inside the power cord The electrical power supply shall be located within the length limitations of the p...

Page 3: ...motor enclosures Refer to Chapter 5 of the National Electric Code or applicable local codes and ordinances for all electrical and wiring requirements in hazardous locations Float switches must be conn...

Page 4: ...sings causing surroundings to become energized At no time shall the pump be stored within an incomplete wet pit The pump should not be placed into the pit until it can be fully operational Do not allo...

Page 5: ...void the T4 temperature class of the pump and will drop the temperature class to T3 200 C Intrinsically safe control panels designed for use with the XLSG XLSGX Series pumps available from Liberty Pum...

Page 6: ...cords cannot be spliced a junction box may be used providing it is rated for hazardous locations and has approved cord connectors IMPORTANT Each cord has a green lead This is the ground wire and must...

Page 7: ...he cutter Besides verification that the cutter and impeller are freely spinning rotating the cutter helps to lubricate the shaft seals if the pump has been non operational for more than a week It is r...

Page 8: ...ected serious damage injury or death can result when power is applied Starting System 1 Verify all plumbing components in the basin are installed correctly and functional Verify all valves are open an...

Page 9: ...ds warranty Table 2 Troubleshooting Matrix Problem Possible Cause Corrective Action Pump does not start Damaged power cable Return pump to an authorized repair facility Control panel selector switch i...

Page 10: ...scharge line is blocked or restricted Check the discharge line for foreign material including ice if the discharge line passes through or into cold areas Check valve is stuck closed or installed backw...

Page 11: ...cation Pump is being run below minimum head requirement causing cavitation A different sized pump or impeller may be required Consult Liberty Pumps Foreign objects in the impeller cavity Clean the imp...

Page 12: ...operated or maintained per manufacturer instructions if it has been disassembled modified abused or tampered with if the electrical cord has been cut damaged or spliced if the pump discharge has been...

Reviews: