Liberty Pumps Omnivore LSG202-RE Installation Manual Download Page 6

6 | EN

Copyright © Liberty Pumps, Inc. 2021 All rights reserved.

5672000J

(9/16 socket) on the discharge flange. This will compress the 

rubber ring and seal the unit.

9.

Open the valve so that the handle/latch encompasses the 

discharge elbow. If problems exist with opening the valve, 

adjustments can be made to the height of the discharge 

elbow by loosening the three screws on the discharge flange 

and raising or lowering the height as needed. Verify screws 

are re-tightened after adjustment.

10.

The control box is designed to be mounted higher in the pit’s 

access chamber and above a potential flood level should a 

power outage occur. Ten feet of cable is provided to the 

control box to accommodate various pit heights. Mount the 

control box as high as possible to the existing vent pipe using 

the supplied brackets and hose clamps. The brackets must 

first be screwed onto the control panel, then install the hose 

clamps through the slotted openings on the bracket.

11.

The 6-pin electrical connector (either round or square) will 

mate up with the existing E/One plug in the pit. No splicing is 

required. Simply connect the plugs together and ensure they 

are fully engaged.

Note: 

The manual override switch will remain operational in 

the original equipment E/One panel.

12.

An auxiliary or second nameplate is provided and should be 

fastened to the existing control panel to properly identify the 

new pump.

Operation

 Starting System

1.

With all electrical and mechanical connections complete and 

secure, turn on power to pump and control panel, if 

applicable.

2.

Verify operation of the pump, floats, and alarm circuits.

3.

Run several cycles of water through the system to verify 

correct control operation for the installation.

Note: 

The alarm float acts as a redundant ON float, activating the 

alarm and pump in the event of a main float switch failure.

Maintenance and Troubleshooting

Refer to supplied Omnivore Installation manual.

Warranty

 Liberty Pumps Wholesale Products Limited Warranty

Liberty Pumps, Inc. warrants that Liberty Pumps wholesale 

products are free from all factory defects in material and 

workmanship for a period of three (3) years from the date of 

purchase (excluding* batteries and “Commercial Series” models). 

The date of purchase shall be determined by a dated sales receipt 

noting the model and serial number of the pump. The dated sales 

receipt must accompany the returned pump if the date of return is 

more than three years from the date of manufacture noted on the 

pump nameplate.
The manufacturer's sole obligation under this Warranty shall be 

limited to the repair or replacement of any parts found by the 

manufacturer to be defective, provided the part or assembly is 

returned freight prepaid to the manufacturer or its authorized 

service center, and provided that none of the following 

warranty-voiding characteristics are evident:
The manufacturer shall not be liable under this Warranty if the 

product has not been properly installed, operated, or maintained 

per manufacturer instructions; if it has been disassembled, 

modified, abused, or tampered with; if the electrical cord has been 

cut, damaged, or spliced; if the pump discharge has been reduced 

in size; if the pump has been used in water temperatures above 

the advertised rating; if the pump has been used in water 

containing sand, lime, cement, gravel, or other abrasives; if the 

product has been used to pump chemicals, grease, or 

hydrocarbons; if a non-submersible motor has been subjected to 

moisture; or if the label bearing the model and serial number has 

been removed.
Liberty Pumps, Inc. shall not be liable for any loss, damage, or 

expenses resulting from installation or use of its products, or for 

indirect, incidental, and consequential damages, including costs of 

removal, reinstallation or transportation.

There is no other express warranty. All implied warranties, 

including those of merchantability and fitness for a particular 

purpose, are limited to three years from the date of purchase. 

This Warranty contains the exclusive remedy of the purchaser, 

and, where permitted, liability for consequential or incidental 

damages under any and all warranties are excluded.

*Liberty Pumps, Inc. warrants StormCell

®

 batteries for 1 year from 

date of purchase, and warrants that pumps of its Commercial 

Series are free from all factory defects in material and 

workmanship for a period of 18 months from the date of 

installation or 24 months from the date of manufacture, 

whichever occurs first, and provided that such products are used 

in compliance with their intended applications as set forth in the 

Clamps

Discharge

Cam locks

Summary of Contents for Omnivore LSG202-RE

Page 1: ...Pumps Inc 2021 All rights reserved For pressure sewer applications verify a Redundant Check Valve Assembly curb stop and check valve is installed between the pump discharge and the street main as clos...

Page 2: ...r cord and could expose the electrically live wires inside the power cord The electrical power supply shall be located within the length limitations of the pump power cord and for below grade installa...

Page 3: ...sin in accordance with local code Proper venting of sewer and effluent gases alleviates poisonous gas buildup and reduces the risk of explosion and fire from these flammable gases Wear adequate Person...

Page 4: ...month should have impellers and cutters manually operated through the breaker panel once a month to lubricate the seals Pumps that are idle in a wet basin must be removed Pump Design LSG LSGX Series g...

Page 5: ...nd national codes 5 Disconnect the electrical quick disconnect plug that is hanging in the basin if applicable 6 Remove bolts securing the current unit if applicable 7 Close valve on current unit 8 Se...

Page 6: ...rcial Series models The date of purchase shall be determined by a dated sales receipt noting the model and serial number of the pump The dated sales receipt must accompany the returned pump if the dat...

Page 7: ...5672000J Copyright Liberty Pumps Inc 2021 All rights reserved 7 EN technical specifications and manuals...

Page 8: ...8 EN Copyright Liberty Pumps Inc 2021 All rights reserved 5672000J...

Reviews: