Model Specifications

For complete listing of models and their specifications, refer to 

http://www.LibertyPumps.com/About/Engineering-Specs. Pump 

nameplate provides a record of specific pump information.

Inspection and Storage

 Initial Inspection

The pump should be immediately inspected for damage that may 

have occurred in shipment.

1.

Visually check the pump and any spare parts for damage.

2.

Check for damaged electrical wires, especially where they exit 

the motor housing.

Contact Liberty Pumps customer service to report any damage or 

shortage of parts.

 Storage Before Use

Protect the power and control cords from the environment. 

Unprotected power and control (switch) cords can allow water 

to wick through ends into pump or switch housings, causing 

surroundings to become energized.

At no time shall the pump be stored within an incomplete wet 

pit. The pump shall not be placed into the pit until it can be 

fully operational.

Do not allow the pump to freeze.

LSG/LSGX-Series Omnivore grinder pumps are shipped from the 

factory ready for installation and use. The pump should be held in 

storage if the pump station is not complete.
If storage is necessary, the pump should remain in its shipping 

container. It should be stored in a warehouse or storage shed that 

has a clean, dry temperature-stable environment where the pump 

and its container are covered to protect it from water, dirt, 

vibration, etc. The cord ends must be protected against moisture.

Uninstalled

 pumps that are idle for greater than three months 

should have cutters and impellers manually rotated once a month 

to lubricate the seals.

Installed

 pumps that are idle for greater than one month should 

have impellers and cutters manually operated through the breaker 

panel once a month to lubricate the seals.
Pumps that are idle in a wet basin must be removed.

Pump Design

LSG/LSGX-Series grinder pumps are designed for continuous 

underwater operation. The motor and pump form a close coupled, 

watertight unit. The induction motor is insulated against heat and 

moisture in accordance with Class B 265°F (130°C) regulations.

A thermal overload protector is embedded in the stator windings. 

This is connected in series and wired to shut down the pump if 

overheating occurs. The overload switch resets automatically 

when the motor cools.
The motor is protected against damage from water entry by two 

seals. The lower seal is a Viton lip seal and the upper seal is a 

graphite impregnated silicon carbide hard face seal.
The impeller and volute are designed for efficient flow 

characteristics and clog-free operation. The hardened cutters 

grind solids and fibrous matter into small particles that can be 

safely pumped through small diameter piping.

Pressure Sewer Applications

A redundant check valve assembly consisting of a curb stop and 

check valve must be installed between the pump discharge and 

the street main, as close to the public right-of-way as possible, on 

all pressure (force main) sewer installations to protect from system 

pressures. The curb stop valve is necessary to isolate the site from 

the pressure sewer while the check valve provides redundant 

protection against potentially detrimental backflow. All valves and 

fittings should be rated for at least 200 PSI service. See Liberty 

Pumps line of CSV-Series Curb Stop/Swing Check Valve 

Assemblies and CK-Series Connection Kit.

Bulkhead 
Connection

Pump Station

Compression 

Adapter 

Fitting

Curb Box

Compression 

Adapter 

Fitting

Valve Extension 
Rod Shown

Curb Stop Valve/Swing 

Check Valve Assembly

To Pump

To Main

Flow

Grade

RISK OF ELECTRIC SHOCK

Summary of Contents for Omnivore LSG202-RE

Page 1: ...Pumps Inc 2021 All rights reserved For pressure sewer applications verify a Redundant Check Valve Assembly curb stop and check valve is installed between the pump discharge and the street main as clos...

Page 2: ...r cord and could expose the electrically live wires inside the power cord The electrical power supply shall be located within the length limitations of the pump power cord and for below grade installa...

Page 3: ...sin in accordance with local code Proper venting of sewer and effluent gases alleviates poisonous gas buildup and reduces the risk of explosion and fire from these flammable gases Wear adequate Person...

Page 4: ...month should have impellers and cutters manually operated through the breaker panel once a month to lubricate the seals Pumps that are idle in a wet basin must be removed Pump Design LSG LSGX Series g...

Page 5: ...nd national codes 5 Disconnect the electrical quick disconnect plug that is hanging in the basin if applicable 6 Remove bolts securing the current unit if applicable 7 Close valve on current unit 8 Se...

Page 6: ...rcial Series models The date of purchase shall be determined by a dated sales receipt noting the model and serial number of the pump The dated sales receipt must accompany the returned pump if the dat...

Page 7: ...5672000J Copyright Liberty Pumps Inc 2021 All rights reserved 7 EN technical specifications and manuals...

Page 8: ...8 EN Copyright Liberty Pumps Inc 2021 All rights reserved 5672000J...

Reviews: