Safety Guidelines

Safety Precautions

 

Always disconnect power before installing or servicing this 

product. Qualified personnel must install and service this 

product according to applicable electrical and plumbing 

codes.

 

Always wear dielectric rubber boots and other applicable 

Personal Protective Equipment (PPE) when water is on the 

floor and an energized pump or alarm system must be 

serviced as submerged electrical connections can energize 

the water. Do not enter the water if the water level is higher 

than the PPE protection or if the PPE is not watertight.

 

Do not install this alarm system outdoors. The system is rated 

for indoor use only.

 

All electrical and safety practices shall be in accordance with 

the National Electrical Code

®

, the Occupational Safety and 

Health Administration, or applicable local codes and 

ordinances.

 

 

Do not use this product with or near flammable or explosive 

fluids such as gasoline, fuel oil, kerosene, etc.

 

This product is not to be installed in locations classified as 

hazardous in accordance with the National Electric Code

®

ANSI/NFPA 70.

Alarm float adapters cannot be used with puck sensors.

Do not cut the connector off a puck sensor and wire it to the 

float adapter. The sensor uses three wires for communication 

and the float adapter only has two terminal blocks. 

General Information

Before use, please read the following instructions carefully. Each 

Liberty Pumps alarm system is tested individually in the factory to 

ensure proper performance and operation. Closely following these 

instructions will eliminate potential operating problems, providing 

years of trouble-free service.
This high water level alarm system is designed for applications 

such as monitoring sump pump basins, sewage pump basins, and 

water powered back-up pumps. The alarm system comes standard 

with a 9V battery backup to enable continuous water level 

monitoring, even when the power is out. A built-in battery 

monitor alerts the user when the 9V battery needs to be replaced. 

Replace product immediately if sensor or power cable becomes 

damaged or severed. 
NightEye® enabled devices come equipped with wireless internet 

connectivity. These devices can connect to your wireless network, 

by means of an Android® or iOS® device, and send notifications 

about your system in real time. This system provides peace of 

mind about the status of your pump system even when you are 

not home.
All of the alarms come standard with Liberty Pumps 360° red 

alarm beacon powered by super-bright LEDs. In combination with 

the 86 dB (at 10 ft/3 m) alarm siren, the alarm is sure to alert 

occupants of any high-water condition.
Each device is specifically designed for use in an indoor residential 

wastewater application. The system comes with liquid level sensor 

that conforms to the needs of the intended application. The 

sensor types are as follows:

Snap-on enclosed float for Sump Pump Applications

ALM-P1, ALM-P1-EYE, SJ10A, SJ10A-EYE

Tethered float for Sewage Pump Applications

:

ALM-2, ALM-2-1, ALM-2-EYE, ALM-2-1-EYE 

Water puck for Puddle Sensing

:

ALM-PK, ALM-PK-EYE

To install up to three sensors, use Liberty Pumps alarm connector 

splitter (sold separately, kit #K001633). A maximum of 2 pucks can 

be used on a single alarm. Acceptable configurations: 3 floats; 2 

floats and 1 puck; or 1 float and 2 pucks.

This safety alert symbol is used in the manual 

and on the pump to alert of potential risk for 

serious injury or death.
This safety alert symbol identifies risk of 

electric shock. It is accompanied with an 

instruction intended to minimize potential 

risk of electric shock.
This safety alert symbol identifies risk of fire

It is accompanied with an instruction 

intended to minimize potential risk of fire.
This safety alert symbol identifies risk of 

serious injury or death. It is accompanied 

with an instruction intended to minimize 

potential risk of injury or death. 
Warns of hazards which if not avoided will 

result in serious injury or death.

Warns of hazards which if not avoided could 

result in serious injury or death.

Warns of hazards which if not avoided could 

result in minor or moderate injury.
Signals an important instruction related to 

the pump. Failure to follow these instructions 

could result in pump failure or property 

damage.

Read every supplied manual before using 

pump system. Follow all the safety instructions 

in manual(s) and on the pump. Failure to do 

so could result in serious injury or death.

RISK OF ELECTRIC SHOCK

RISK OF FIRE

Summary of Contents for ALM Series

Page 1: ...tion Manual 2138000G Copyright Liberty Pumps Inc 2021 All rights reserved ALM Series Indoor Alarms Features NEMA 1 enclosure Rated for indoor use only Automatic alarm and alarm silence reset 360 red alarm indicator beacon 4 ft 1 2 m power cord 9V Battery back up with low battery indicator Multiple level sensing options available Auxiliary dry contacts for triggering external alarm Pre installed co...

Page 2: ...ble becomes damaged or severed NightEye enabled devices come equipped with wireless internet connectivity These devices can connect to your wireless network by means of an Android or iOS device and send notifications about your system in real time This system provides peace of mind about the status of your pump system even when you are not home All of the alarms come standard with Liberty Pumps 36...

Page 3: ...p Make sure the float cable is not allowed to touch the excess hose clamp band during operation Note All hose clamp components are made of 18 8 stainless steel See your Liberty Pumps distributor for replacements 4 Route the sensor cable out of the sewage pit and connect it to the bottom of the alarm enclosure ensuring it does not interfere with the operation of the primary pump s float Sump Pump S...

Page 4: ...larms off once the condition has been corrected Warranty Liberty Pumps Wholesale Products Limited Warranty Liberty Pumps Inc warrants that Liberty Pumps wholesale products are free from all factory defects in material and workmanship for a period of three 3 years from the date of purchase excluding batteries and Commercial Series models The date of purchase shall be determined by a dated sales rec...

Page 5: ... Pumps Inc 2021 All rights reserved Todos los derechos reservados Tous les droits sont réservés This page intentionally left blank Esta página se dejó en blanco intencionalmente Cette page a été intentionnellement laissée vierge ...

Page 6: ...ht Liberty Pumps Inc 2021 All rights reserved Todos los derechos reservados Tous les droits sont réservés 2138000G Mounting Hole Locations Emplacement des trous de fixation Ubicacioines del orificio de montaje ...

Reviews: