Installation

 

 

Figure 1 

Sump Pump Sensor Installation 

Figure 2 

Sewage Pump Sensor Installation 

Figure 3 

Connection locations on bottom of alarm unit. 

Note the 9V battery installation—paying        

attention to polarity, the battery should gently 

push into place and latch on the ledge at the 

bottom of the battery chamber. 

RISK OF ELECTRIC SHOCK 

NEVER install this alarm system outdoors. The system 

is rated for indoor use only. 

Sensor Installation 

Sump Pump Sensor 

1)  Remove sump pump sensor from packaging.  
2)  Apply a small amount of glue to the inside of the snap feature of the 

sensor. 

NOTE: Over-gluing the sensor will make future removal 

very difficult. 

 

3)  Snap sensor over the discharge pipe of your sump pump as shown 

in 

Figure 1

.  

4)  Route the sensor cable out of the sump pit and connect it to the 

bottom of the alarm enclosure. See 

Figure 3

Sewage Pump Sensor

 

1)  Place the float switch cord into the clamp as shown in 

Figure 2

2)  Locate the clamp at the desired activation level and secure the 

clamp to the pump discharge pipe as shown in 

Figure 2

Note:

 Do not install cord under hose clamp. 

3)  Tighten the hose clamp using a screwdriver. Over tightening may 

result in damage to the plastic clamp. Make sure the float cable is 
not allowed to touch the excess hose clamp band during operation. 

Note:

 All hose clamp components are made of 18-8 stainless 

steel. See your Liberty Pumps

®

 supplier for replacements. 

4)  Route the sensor cable out of the sewage pit and connect it to the 

bottom of the alarm enclosure ensuring it does not interfere with the 
operation of the primary pump’s float. See 

Figure 3

Water Puck Sensor 

1)  Remove the puck sensor from its packaging.  
2)  Place sensor in the location susceptible to water intrusion or buildup 

(example: under hot water heater, near laundry sink, near 
problematic foundation wall, etc.). 

3)  Route water puck cable such that it will not pose a tripping hazard.  
4)  Plug water puck cable into the ALM sensor connector.  
5)  Test water puck for operation by setting it in a small puddle or by 

holding a damp towel on its bottom surface. 

To install up to 3 sensors, use a Liberty alarm connector splitter 
(sold separately, Kit: K001633). 

Enclosure Installation 

1)  Select an indoor mounting location for the alarm unit. Liberty 

Pumps recommends a location between 48in (1.2m) and 66in 
(1.7m) above floor level. 

2)  Using the supplied template on the rear cover of this manual, mark 

screw locations on the mounting surface.  

3)  If the screw locations are 

NOT 

directly over a wall stud, or the 

alarm will be mounted to a masonry wall, the use of the supplied 
anchors is recommended. A 3/16” (5mm) hole must be drilled 
before inserting the anchor into the wall. 

4)  Mount the alarm enclosure to the wall using the supplied anchors 

and screws (where applicable). 

 

© Copyright 2017 Liberty Pumps Inc.    All rights reserved

 

2

 

Summary of Contents for ALM-2

Page 1: ...y back up with low battery indicator Pre installed connector on level sensor for plug and play installation Auxiliary dry contacts for triggering external alarm Multiple level sensing options availabl...

Page 2: ...ndividually in the factory to ensure proper performance and operation Closely following these instructions will eliminate potential operating problems providing years of trouble free service This high...

Page 3: ...operation Note All hose clamp components are made of 18 8 stainless steel See your Liberty Pumps supplier for replacements 4 Route the sensor cable out of the sewage pit and connect it to the bottom...

Page 4: ...device The alarm will stay silenced for 6 hours after the silence button is pressed 4 Once testing is complete lower the water level in the pit back to its normal range Sewage Pump Sensor 1 Manually...

Page 5: ...FORTH ABOVE ARE IN LIEU OF ALL OTHER WARANTIES EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND ALL SUCH OTHER WARRANTIES ARE H...

Page 6: ...dicadora de alarma de 360 4 pies 1 2 m cable de alimentaci n Reserva de bater a de 9 V con indicador de bater a baja Conector preinstalado en sensor de nivel para instalaci n inmediata Contactos secos...

Page 7: ...era individual en la f brica para asegurar el rendimiento y funcionamiento correctos Siga estas instrucciones al pie de la letra para prevenir problemas de funcionamiento y conseguir muchos a os de se...

Page 8: ...abrazadera de la manguera est n hechos de acero inoxidable 18 8 Visite a su proveedor de Liberty Pumps para conseguir repuestos 4 Encamine el cable del sensor hacia afuera del hoyo de la fosa de aguas...

Page 9: ...permanecer silenciada durante 6 horas despu s de que se presione el bot n 4 Una vez que se complete la prueba disminuya al rango normal el nivel de agua en la fosa Sensor de bombas para aguas residua...

Page 10: ...COMERCIABILIDAD O DE IDONEIDAD PARA UN PROP SITO EN PARTICULAR Y LIBERTY PUMPS INC RECHAZA Y EXCLUYE TODAS ESAS GARANT AS POR MEDIO DE ESTE DOCUMENTO Garant a limitada por 3 a os Instalaci n continua...

Page 11: ...teur de pile faible Raccordement du d tecteur de niveau pr install pour installation pr te l emploi Contacts secs auxiliaires pour le d clenchement de l alarme ext rieure Options de d tecteur plusieur...

Page 12: ...ves avant d utiliser ce produit Chaque syst me d alarme pour pompe Liberty est test individuellement en usine pour assurer un bon rendement et fonctionnement Le fait de suivre ces directives la lettre...

Page 13: ...adresser au fournisseur Liberty PumpsMD pour obtenir des pi ces de rechange 4 Diriger le c ble du d tecteur vers l ext rieur de la fosse de r tention des eaux us es et le raccorder au fond de l encein...

Page 14: ...e silencieuse pendant six heures avec le bouton de silence 4 Une fois la v rification termin e abaisser le niveau d eau dans le puisard son niveau normal D tecteur de pompe de relevage des eaux us es...

Page 15: ...ONT EXCLUSIVES ET REMPLACENT TOUTE AUTRE GARANTIE EXPRESSE OU IMPLICITE Y COMPRIS LES GARANTIES DE QUALIT MARCHANDE ET D APTITUDE UNE FIN PARTICULI RE SANS SE LIMITER CELLES CI DE TELLES AUTRES GARANT...

Page 16: ...Copyright 2017 Liberty Pumps Inc All rights reserved Mounting Hole Locations Emplacement des trous de fixation Ubicacioines del orificio de montaje...

Reviews: