ColorSave 1000ST-INJ user manual
22
4.3 Configuration Parameters Setup
4.3.1 Setting Parameter Values
While in main screen:
Press
Maintenance
button
to
enter
Maintenance screen
Press
Parameters
button
to
enter
Parameters screen
Press Next button to enter Parameters2
screen
4.3.2 Setting Installed Screw Number
Each dosing screw is marked by its identifying number:
"0" – Micro capacity
2 pellet/shot to 0.2 kg/h
"1" – Low capacity
0.1 – 4 kg/h
"2" – Medium capacity
0.2 – 10 kg/h
"3" – High Capacity
0.4 – 18 kg/h
"4" – Extra high capacity
0.6 – 35 kg/h
See section 2.2 Feeding (dosing) Screws for more information
To change screw, enter Parameters screen (see section 4.3.1 Setting parameter values),
press the Screw button and set the new desired screw number
Proceed with other parameters or press Back button to return to Maintenance Screen