5. Water flow setup

www.lgmaquari.it | [email protected]

Skimmer

LGs450

LGs600 SP

LGs800/II
LGs900/II

LGs950

Max Flow

 

lt/h (US gal/h)

350 (90)

700 (185)
850 (225)
950 (250)

1.100 (290)

Max Flow

 

lt/h (US gal/h)

1.300 (345)
2.000 (530)
2.500 (660)
3.000 (790)

Skimmer

LGs1260
LGs2000
LGs2500
LGs3000

v.1.1 ENG | 450~3000 | 03-2014

Adjust the amount of water flow, using a valve or the flow regulator of the water intake pump 
connected to      . The flow must be adjusted according to the here below table and your skimmer 
model.

LGMAquari

 's skimmers can achieve different performances, by working on several fine calibrations. 

You can obtain very different results by acting on the adjustments of the air, amount of water treated 
and the level in the contact column.

 Correct air flow

Wrong air flow or level in  A too high

For fine adjust, use a graduated bowl to measure the amount of water flowing from the outlet pipe H  .

Manufacturers always report a flow value for their 
intake pumps. This is not a valid reference to setup 
the skimmer. Once the water flow rate is properly 
adjusted, rise or lower the height level of H   to 
bring the water level inside the column D  close to 
the base of the Contact Column neck. The water 
should not fill the neck (water must fill the conical

part of the Contact Column      , without entering the Collector Cup neck B  ).
Turn on the pump       and adjust the air flow through G  in order to obtain a foam, not too dry but very 
dense and dark. The air adjustment is empirical, according to the organic load of the tank, the skimmer 
model and some other minor factors.

Correct water level

Summary of Contents for LGs1260

Page 1: ...M ade in Italy User Manual LGs450 LGs600sp LGs800 II LGs900 II LGs950 LGs1260 LGs2000 LGs2500 LGs3000 Skimmer...

Page 2: ...Collector dropdown neck Skimmer Pump Venturi joint Air flow regulator H 1 2 3 4 5 Outlet pipe Suction line inlet with O Ring Water Pump intake inlet Air intake silencer Waste drain outlet Clean water...

Page 3: ...y noiseless If you use a 90 joint instead of a T to maintain proper stability of use it will not be possible to immerse the vertical pipe in any case LGMAquari s skimmers are equipped with an exhaust...

Page 4: ...cm 1 in case of use of a T joint The adjustment of the amount of water treated and the levels must be done with all fittings mounted 4 Water intake pump startup 3 Water direction www lgmaquari it lgma...

Page 5: ...ater treated and the level in the contact column Correct air flow Wrong air flow or level in A too high For fine adjust use a graduated bowl to measure the amount of water flowing from the outlet pipe...

Page 6: ...that may inhibit the skimming process It is strongly recommended that only tubes specifically designed for aquariums and for food should be used 6 Warning on startup adjustment 7 Maintenance www lgmaq...

Page 7: ...ller cleaned and reassembled Detail of the bushings and shaft for reassembly v 1 1 ENG 450 3000 03 2014 8 1 Turn o and disconnect all electrical equipment in the Acquarium and or Sump before carryng o...

Page 8: ...uari is not legally bound to update upgrade or modify any product LGMAquari is not responsible for any errors that may appear in this document LGMAquari shall never be liable for accidental damages du...

Page 9: ...um deposits or inappropriate repair modification by unauthorized personnel are not under any warranty 3 All consumables are not under warranty eg O rings rubber tubes shaft etc or more general ly all...

Reviews: