background image

9

Multi-Protocol Operation 

Analog Operation

This decoder can also be operated on analog layouts or areas of track that are 

analog. The decoder recognizes alternating current (DC) and automatically adapts 

to the analog track voltage. All functions that were set under mfx or DCC for analog 

operation are active (see Digital Operation).

The built-in sound functions come from the factory inactive for analog operation.

Digital Operation

The built-in multi-protocol decoder can be used alternatively for operation with 

a conventional DC locomotive controller (max. ±24 volts), mfx, or digital systems 

adhering to the NMRA norm (DCC). The decoder automatically recognizes the mode 

of operation, with priority for mfx. 

Note:

 Digital protocols can influence each other. For trouble-free operation, we re-

commend deactivating those digital protocols not needed by using CV 50. Deactivate 

unneeded digital protocols at this CV if your controller supports this function. 

Note: 

Please note that not all functions are possible in all digital protocols. Several 

settings for functions, which are supposed to be active in analog operation, can be 

done under mfx and DCC.  

Notes on digital operation 

•   The operating instructions for your central unit will give you exact procedures for 

setting the different parameters. 

•   The values set at the factory have been selected for mfx in order to guarantee the 

best possible running characteristics.  

Adjustments may have to be made for other operating systems. 

mfx Protocol

Addresses 

•   No address is required; each decoder is given a one-time, unique identifier (UID).

•   The decoder automatically registers itself on a Central Station or a Mobile Station 

with its UID-identifier.

Programming 

•   The characteristics can be programmed using the graphic screen on the Central 

Station or also partially with the Mobile Station.

•   All of the Configuration Variables (CV) can be read and programmed repeatedly.

•   The programming can be done either on the main track or the programming track.

•   The default settings (factory settings) can be produced repeatedly.

•   Function mapping: Functions can be assigned to any of the function but-

tons with the help of the 60212 Central Station (with limitations) and with the 

60213/60214/60215/60216 Central Station (See help section in the Central Station).

DCC Protocol

Addresses 

•   Short address – long address – multiple unit address

•   Address range:  

1 – 127 for short address and multiple unit address,  

1 – 10239 for long address 

•   Every address can be programmed manually.

•   Short or long address is selected by means of CV 29 (Bit 5).

•   A multiple unit address that is being used deactivates the standard address. 

•   Address set at the factory: 

03

Programming 

•   The characteristics can be changed repeatedly using the Configuration Variables (CV).

•   The CV numbers and the CV values are entered directly.

•   The CVs can be read and programmed repeatedly. (Programming is done on the 

programming track.)

•   The CVs can be programmed in any order desired. (PoM - Programming can be done 

on the main track). PoM is not possible with CVs CV 1, 17, 18, and 29. PoM must be 

supported by your central controller (Please see the description for this unit.).

•   The default settings (factory settings) can be produced repeatedly.

•   14 or 28/126 speed levels can be set.

•   See the CV description for the DCC protocol for additional information.

We recommend that in general programming should be done on the programming track.

Summary of Contents for 20283

Page 1: ...Modell der D S Dampflok Mogul 20283...

Page 2: ...2...

Page 3: ...n handhaving 18 Schakelbare functies 18 CV 19 Afbeeldingen 28 Onderdelen 29 Indice del contenuto Pagina Avvertenze per la sicurezza 24 Avvertenze importanti 24 Funzioni 24 Avvertenze per ilfunzionamen...

Page 4: ...erkannt Mfx Technologie f r Mobile Station Central Station Name ab Werk Durango 288 Die Funktionen k nnen nur parallel aufgerufen werden Die seriealle Funktionsaus l sung ist nicht m glich beachten Si...

Page 5: ...coder erh lt eine einmalige und eindeutige Kennung UID Der Decoder meldet sich an einer Central Station oder Mobile Station mit seiner UID Kennung automatisch an Programmierung Die Eigenschaften k nne...

Page 6: ...uchtung 1 LV LR Ger usch Pfeife lang 1 Sound 2 Ger usch Bremsenquietschen aus 2 Ger usch Pfeife kurz 3 Sound 1 Ger usch Glocke 4 Sound 17 Ger usch Kohle schaufeln 5 Sound 9 Ger usch Betriebsger usch 1...

Page 7: ...v 0 1 0 2 0 4 0 32 6 50 Alternative Formate Bit 0 Analog AC Bit 1 Analog DC Bit 2 MM Bit 3 mfx aus an 0 1 0 2 0 4 0 8 14 60 Multibahnhofsansage Bit 0 3 Anzahl der Bahnh fe Bit 4 Endansage wechselt die...

Page 8: ...gnized in operation with mfx Mfx technology for the Mobile Station Central Station Name set at the factory Durango 288 The functions can be activated only in parallel Serial activation of the function...

Page 9: ...omatically registers itself on a Central Station or a Mobile Station with its UID identifier Programming The characteristics can be programmed using the graphic screen on the Central Station or also p...

Page 10: ...1 Sound 2 Sound effect Squealing brakes off 2 Sound effect Short whistle blast 3 Sound 1 Sound effect Bell 4 Sound 17 Sound effect Coal being shoveled 5 Sound 9 Sound effect Operating sounds 1 2 6 FS...

Page 11: ...ort long address active 0 1 0 2 0 4 0 32 6 50 Alternative Formats Bit 0 Analog AC Bit 1 Analog DC Bit 2 MM Bit 3 mfx off on 0 1 0 2 0 4 0 8 14 60 Multi station announcement Bit 0 3 Number of stations...

Page 12: ...ive est reconnue automatiquement Technologie mfx pour Mobile Station Central Station Nom encod e en usine Durango 288 Les fonctions ne peuvent tre d clench es qu en parall le Le d clenchement des fon...

Page 13: ...ication unique et non quivoque UID Avec son UID identification le d codeur indique automatiquement une station centrale ou une station mobile qu il est connect Programmation Les caract ristiques peuve...

Page 14: ...fflet longueur 1 Sound 2 Bruitage Grincement de freins d sactiv 2 Bruitage sifflet court 3 Sound 1 Bruitage Cloche 4 Sound 17 Bruitage Pelletage du charbon 5 Sound 9 Bruitage Bruit d exploitation 1 2...

Page 15: ...0 4 0 32 6 50 Formats alternatifs Bit 0 Analogique AC Bit 1 Analogique c c Bit 2 MM Bit 3 Mfx d sactiv activ 0 1 0 2 0 4 0 8 14 60 Annonce en gare multiple Bit 0 3 Nombre des gares Bit 4 Annonce final...

Page 16: ...end Mfx technologie voor het Mobile Station Central Station Naam af de fabriek Durango 288 De functies kunnen alleen parallel geschakeld worden Het serieel schakelen van de functies is niet mogelijk z...

Page 17: ...duidig kenmerk UID De decoder meldt zich vanzelf aan bij het Central Station of Mobile Station met zijn UID kenmerk Programmering De eigenschappen kunnen m b v het grafische scherm op het Central Stat...

Page 18: ...ting 1 LV LR Geluid fluit lang 1 Sound 2 Geluid piepende remmen uit 2 Geluid fluit kort 3 Sound 1 Geluid luidklok 4 Sound 17 Geluid kolenscheppen 5 Sound 9 Geluid bedrijfsgeluiden 1 2 6 FS Rookgenerat...

Page 19: ...2 6 50 Alternatief formaat Bit 0 Analoog AC Bit 1 Analoog DC Bit 2 MM Bit 3 mfx uit aan 0 1 0 2 0 4 0 8 14 60 Multi station omroep Bit 0 3 aantal stations Bit 4 eindstation omroep volgorde wijzigt Bit...

Page 20: ...i n de locomotora 03 En funcionamiento con mfx la locomotora es identificada autom ticamente Tecnolog a mfx para la Mobile Station Central Station Nombre de f brica Durango 288 Las funciones se pueden...

Page 21: ...identificaci n universalmente nica e inequ voca UID El decoder se da de alta autom ticamente en una Central Station o en una Mobile Station con su UID identificaci n Programaci n Las caracter sticas...

Page 22: ...a con unas pinzas Enchufar la l mpara de incandescencia nueva Funciones conmutables Faros 1 LV LR Ruido del silbido larga 1 Sound 2 Ruido Desconectar chirrido de los frenos 2 Ruido del silbido corta 3...

Page 23: ...ico AC Bit 1 Anal gico DC Bit 2 MM Bit 3 desactivar activar mfx 0 1 0 2 0 4 0 8 14 60 Locuci n multiestaci n Bit 0 3 N mero de estaciones Bit 4 La locuci n final cambia el orden Bit 5 El sentido de ci...

Page 24: ...obile Station Central Station Nome di fabbrica Durango 288 Le funzioni possono venire messe in azione solo in modo parallelo L azionamento seriale delle funzioni non possibile prestate attenzione a qu...

Page 25: ...l Decoder si annuncia automaticamente ad una Central Station oppure Mobile Station con il suo UID identificazione Programmazione Le caratteristiche possono venire programmate tramite la superficie gra...

Page 26: ...mutabili Illuminazione 1 LV LR Rumore Fischio lunga 1 Sound 2 Rumore stridore dei freni escluso 2 Rumore Fischio breve 3 Sound 1 Rumore Campana 4 Sound 17 Rumore Spalatura del carbone 5 Sound 9 Rumore...

Page 27: ...breve lungo attivo 0 1 0 2 0 4 0 32 6 50 Formati alternativi Bit 0 AC analogica Bit 1 DC analogica Bit 2 MM Bit 3 mfx spento attivo 0 1 0 2 0 4 0 8 14 60 Annunci di stazione multipli Bit 0 3 numero d...

Page 28: ...e Afb 2 Volumeregelaar Fig 2 Regulador de volumen de sonido Figure 2 regolatore di volume sonoro Bild 1 Betriebsartenschalter Fig 1 Power control switch Img 1 Modes d exploitation Afb 1 Bedrijfssoorte...

Page 29: ...29 7 13 8 9 9 2 8 12 12 11 12 12 10 3 12 9 14 6 1 14 14 Details der Darstellung k nnen von dem Modell abweichen...

Page 30: ...30 18 26 25 7 24 23 22 12 30 29 23 10 32 23 27 25 28 17 32 22 5 21 15 16 10 13 13 10 17 20 19 31 13 10 7 27 Details der Darstellung k nnen von dem Modell abweichen...

Page 31: ...31 10 33 35 36 10 35 34 10 40 12 34 34 10 38 37 34 10 4 34 39 41 34 41 Details der Darstellung k nnen von dem Modell abweichen...

Page 32: ...38 Drehgestell ohne Haken E174 594 39 Drehgestell mit Haken E174 600 40 Metall Scheibenradsatz 67 419 41 Kupplung E171 327 Klauenkupplung E174 496 Magnetgeh use E133 140 Hinweis Einige Teile werden nu...

Page 33: ...Erweiterte Decoderwerte Werkseinstellung 20283...

Page 34: ...sive knowledge of working with DCC La liste suivante indique la configuration d usine du d codeur pour r f 20283 en ce qui concerne le mappage de fonctions Les param tres peuvent tre modifi s plusieur...

Page 35: ...Event 353 255 Zuweisung31 Trigger 354 0 Zuweisung31 Flags 355 255 Zuweisung31 Event CV Value Description CV Wert Bedeutung 284 3 Zuweisung8 Trigger 285 0 Zuweisung8 Flags 286 177 Zuweisung8 Event 287...

Page 36: ...t 425 255 Zuweisung55 Trigger 426 0 Zuweisung55 Flags 427 255 Zuweisung55 Event CV Value Description CV Wert Bedeutung 356 255 Zuweisung32 Trigger 357 0 Zuweisung32 Flags 358 255 Zuweisung32 Event 359...

Page 37: ...t 497 255 Zuweisung79 Trigger 498 0 Zuweisung79 Flags 499 255 Zuweisung79 Event CV Value Description CV Wert Bedeutung 428 255 Zuweisung56 Trigger 429 0 Zuweisung56 Flags 430 255 Zuweisung56 Event 431...

Reviews: