8 ) W a t e r d r a i n s t h o u g h i t i s n o t t h e t i m e o f d r a i n .
Where, what & how to check?
Result of Check
Possible Cause How to repair & settle
Drain Motor
(for Non-Pump Model only)
1. Check whether the drain motor is
normally returned after turning
power off.
(It is considered normal if the lever
of the drain motor is fully pulled out
by the PV spring)
PV Case
1. If water drains though the drain
motor is normally returned, check
whether PV asm is blocked by
foreign objects or the bellows in
the PV asm is deformed.
Controller
1. Check whether the drain motor or
the drain pump works immediately
after power is turned on.
Blocked.
Blocked.
Bellows
deformed.
Works.
Defect of the drain
motor.
Defect of PV
Bellows.
Defect of the
controller(Triac
defect)
Change the drain motor.
Remove the objects in
the PV asm.
Change the PV bellows.
(The bellows may swell
up if it contact petroleum
or petrochemical
substance because it is
made of rubber)
Change the controller.
9 ) D r a i n e r r o r h a p p e n s w h i l e w a t e r d r a i n s n o r m a l l y.
Where, what & how to check?
Result of Check
Possible Cause How to repair & settle
Ball Pressure Sensor
(Pressure Switch)
1. Check generation frequency of the
Ball Pressure Sensor
(Pressure Switch) without water.
Less than
26.3 kHz
26.3~27.1 kHz
Defect of the
Ball Pressure
Sensor(Pressure
Switch).
Defect of the
controller.
Change the Ball
Pressure Sensor
(Pressure Swtich)
Change the controller.
46
Summary of Contents for WTS14BSL
Page 18: ...3 4 WASHING PROGRAMS Course 18 ...
Page 19: ...Course 19 ...
Page 20: ...Course 20 ...
Page 21: ...21 ...
Page 22: ...3 5 OTHERS FUNCTIONS 1 SOAK Wash Course Course 22 ...
Page 24: ...3 5 OTRAS FUNCIONES 3 AIR DRY AIR DRY for your laundary 24 ...
Page 26: ...3 5 OTRAS FUNCIONES 5 DELAY START RESERVATION Wash 26 ...
Page 51: ...51 ...
Page 53: ...F070 F090 F080 F020 F027 F001 F000 For Pump For Non Pump F020 F021 F040 Non Service Part ...
Page 55: ...P No MFL69262915 August 2015 PRINTED IN THAILAND ...