- 4 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
POWER SUPPLY
COOLING CAPACITY
(Btu/h)
INPUT
(W)
RUNNING CURRENT
(A)
E.E.R
(BTU/W.h)
HEATING CAPACITY
(Btu/h)
INPUT
(W)
RUNNING CURRENT
(A)
INDOOR
(°C)
OUTDOOR (°C)
REFRIGERANT (R-22) CHARGE
EVAPORATOR
CONDENSER
FAN, INDOOR
FAN, OUTDOOR
FAN SPEEDS, FAN/HEATING/COOLING
FAN MOTOR
OPERATION CONTROL
ROOM TEMP. CONTROL
AIR DIRECTION CONTROL
CONSTRUCTION
ELECTRIC HEATER
COMPRESSOR
PROTECTOR
FAN MOTOR
ELECTRIC HEATER
POWER CORD
DRAIN SYSTEM
NET WEIGHT
(lbs/kg)
OUTSIDE DIMENSION
(inch)
(W x H x D)
(mm)
11,500/12,000
1,250/1,220
6.2/5.5
9.8
9,200/11,200
2,900/3,500
14/15.3
26.7(DB)* 19.4(WB)**
35(DB)* 23.9(WB)**
555g (19.5 oz)
2 ROW 17 STACKS, LOUVERED-FIN TYPE
BLOWER
PROPELLER TYPE FAN WITH SLINGER-RING
1/2/2
6 POLES
ROTARY SWITCH OR ROCKER SWITCH
THERMOSTAT
VERTICAL LOUVER (RIGHT & LEFT)
HORIZONTAL LOUVER (UP & DOWN)
SLIDE IN-OUT CHASSIS
3.5KW, 230V
OVERLOAD PROTECTOR
INTERNAL THERMAL PROTECTOR
FUSE LINK, BIMETAL THERMOSTAT
(3 WIRE WITH GROUDING)
ATTACHMENT PLUG (CORD-CONNECTED TYPE)
DRAIN PIPE OR SPLASHED BY FAN SLINGER
97/44
23
5
/
8
x 14
31
/
32
x 22
5
/
16
600 x 380 x 567
1ø, 208/230V, 60Hz
R1203H
MODELS
ITEMS
OPERATING
CONDITION
1.3.2 FOR R1203H
2 ROW 13 STACKS LOUVERED-FIN TYPE
* DB:Dry Bulb
** WB:Wet Bulb