24
SPIN
OPTION
SPIN
OPTION
NO
YES
YES
YES
YES
NO
NO
NO
YES
(1)
(1)
(2)
SPIN TROUBLE
Door does not open
Check the S.PRESSURE SWITCH
ASSEMBLY or HOSE (Pressure).
If the problem is on the
S.PRESSURE SWITCH
ASSEMBLY or the HOSE,
replace the S.PRESSURE
SWITCH ASSEMBLY or the
HOSE.
Normal
Correct the connector.
Replace the STATOR
ASSEMBLY
Check on the spinning, is the frequency of the
water level 248 or more. The frequency can be
checked by pressing the OPTION and SPIN buttons
at the same time on the program.
When pressing OPTION, SPIN and POWER buttons
at the same time after power off, press the
START/PAUSE button 1 times, is the drum spinning
at low speed?
Is it disconnected, or disassembled?
[Red:3pin (1), NA:4pin (2)]
Check the motor connector, Is the resistance of
the terminal same as the figure?
MOTOR TERMINAL (1)
Resistance of terminal:
¥L~¥M / ¥M~¥N / ¥N~¥L
About 5
Ω
15
Ω
Replace the MAIN PWB ASSEMBLY
Check switch Assembly,
Door lock connector and
Main PWB ASSEMBLY
(Blue, 3pin)
Is
Displayed?
¥L
¥M
¥N