When checking the voltage between
connector during whites washing. is the
voltage 120V?
Replace the MAIN PWB
ASSY
YES
NO
After power off and the heater terminal is
disconnected, is the resistance 10~30 ?
When pressing WATER TEMP. during, is the
displayed temperature is over 10ûC
higher than the selected temperature?
Is the resistance between Thermistor
Comectors 2.5k ~ 180k ?
Replace the
HEATER ASSEMBLY
Check if inlet hose is
connected to a hot
faucet ; otherwise,
replace PWB
ASSEMBLY(Main)
Replace Thermister
NO
After power off,is the resistance of wire
(RED-YELLOW) connectors between
10 ~30 ?
Normal
NO
YES
RED
YELLOW
1 2 3
YES
AC 120V
(1)
Push the THERMISTOR
tightly to the rubber.
When checking THERMISTOR on the tub is the
THERMISTOR loosened above 2mm from
the rubber?
HEATING CONTINUOUSLY ABOVE
THE SETTING WATER TEMPERATURE
WASH HEATER TROUBLE