1 9
Part 5
PROGRAMMING MODE -
Test Mode
Data Name
Entering
the test mode
1. Entering programming mode
2. MEDICAL 90
3. START
Push and hold the MEDICAL 90 and NORMAL 60 at the same time.
After that push NORMAL 75 button for 3 times. Push START button.
Press the MEDICAL 90 button. Then appears in the
display.
Enter the diagnostic test mode.
Button
Display
Description
Entering the test mode
Diagnostic tests: (display)
This program has been added for testing the washer and detecting errors.
11
According to pressing START button, test move to the next step.
• Make sure the drum is empty when a diagnostic test is performed. Do not use .
Note
Number of times the
START button is pressed
Check Point
None
1time
2 times
3 times
4 times
5 times
6 times
7 times
8 times
9 times
10 times
11 times
12 times
13 times
14 times
15 times
16 times
17 times
Turns on all lamps and locks the door
Tumble Clockwise.
Low Speed Spin
High Speed Spin
Inlet valve for main water turns on.
Inlet valve for hot wash turns on.
Inlet valve for softener turns on.
Inlet valve for bleach turns on.
Tumble counter clockwise.
Turn on the heater
Drain Pump turns on
Turn on Circulation Pump
Turns on all lamps.
Button Checks.
High Speed Spin
PDA Signal Check
Display
Displayed EU XX and LE XX alternately
(Version)
rpm (40~50)
rpm (600)
rpm (1000)
Water level frequency (261~)
Water level frequency (261~)
Water level frequency (261~)
Water level frequency (261~)
rpm (40~50)
Displayed 0XX
Water level frequency (261~)
Displayed 0XX
Displayed EU XX and LE XX alternately
Displayed EU XX and LE XX alternately
rpm(1000)
this function is not applied in this machine