SAFETY PRECAUTIONS

ENGLISH

Operation

• Do not let the air conditioner run for a long time when the humidity is very high or when a door or

window has been left open. Failure to do so may result in product failure.

• Make sure that the power cord is not pulled or damaged while the air conditioner is operating. Fail-

ure to do so may result in fire, electric shock, or product failure.

• Do not place any objects on the power cord. It may result in electric shock or product failure.

• Do not turn on or off the air conditioner by plugging in or unplugging the power plug. It may result in

fire or electric shock.

• Do not touch, operate or repair the air conditioner with wet hands. It may result in electric shock or

product failure.

• Do not place a heater or other heating appliances near the power cable. It may result in fire, electric

shock, or product failure.

• Do not allow water to run into the air conditioner. It may result in explosion or fire.

• Do not leave flammable substances such as gasoline, benzene and thinner near the air conditioner.

It may result in explosion or fire.

• Do not use the air conditioner for an extended period of time in a small place without ventilation.

Ventilate the place regularly. Failure to do so may result in explosion or fire.

• When there is a gas leak, ventilate sufficiently before using the air conditioner again. Failure to do so

may result in explosion or fire.

• Unplug the power plug if there is a noise, smell or smoke coming from the air conditioner. Failure to

do so may result in explosion or fire.

• Stop operating and close the window in strom or hurricane.If possible remove the product from the

window  before hurricane arrives

• Contact an authorized service center when the air conditioner is submerged into water due to flood-

ing. Failure to do so may result in explosion or fire.

• Be cautious water could not enter the product

• Make sure to ventilate sufficiently when this air conditioner and a heating appliance such as a heater

are used simultaneously. Failure to do so may result in fire, serious injury, or product failure.

• Turn the main power off and unplug the power plug when you clean or repair the air conditioner.

Failure to do so may result in death, serious injury, or product failure.

• Unplug the power plug when the air conditioner is not used for an extended period of time. Failure

to do so may result in product failure.

• Do not place any objects on the air conditioner. It may result in product failure.

• For inner cleaning, contact an Authorized Service Center or a dealer. Do not use harsh detergent

that causes corrosion or damage on the unit. Harsh detergent may also cause failure of product, fire,

or electronic shock.

• This appliance is not intended for use by persons (including children) with reduced physical, sensory

or mental capabilities, or lack of experience and knowledge unless they have been given supervision

or instruction concerning use of the appliance by a person responsible for their safety.

• Children should be supervised to ensure that they do not play with the appliance.

Summary of Contents for VR122CL NB2

Page 1: ...P NO MFL67735106 OWNER S MANUAL Please read this manual carefully before operating your set and retain it for future reference TYPE WALL MOUNTED INVERTER MODELS Indoor Unit VR122CL NB2 VR182CL NC2 VR242CL NC2 AIR CONDITIONER www lg com ENGLISH ESPAÑOL ...

Page 2: ...irection of the air flow vertically or horizontally to circulate indoor air Speed up the fan to cool or warm indoor air quickly in a short period of time Open windows regularly for ventilation as the indoor air quality may deteriorate if the air con ditioner is used for many hours Clean the air filter once every 2 weeks Dust and impurities collected in the air filter may block the air flow or weak...

Page 3: ...r and fuse conforming with the rating of the air conditioner Fail ure to do so may result in electric shock or product failure Contact an authorized service center when you install or relocate the air conditioner Failure to do so may result in serious injury or product failure Always use a power plug and socket with a ground terminal Failure to do so may result in electric shock or product failure...

Page 4: ...ere is a noise smell or smoke coming from the air conditioner Failure to do so may result in explosion or fire Stop operating and close the window in strom or hurricane If possible remove the product from the window before hurricane arrives Contact an authorized service center when the air conditioner is submerged into water due to flood ing Failure to do so may result in explosion or fire Be caut...

Page 5: ...er or spray water Use a smooth cloth It may result in serious injury or product failure Never touch the metal parts of the air conditioner when you remove the air filter It may result in se rious injury or product failure Do not place any objects on the air conditioner It may result in product failure Always insert the filter securely after cleaning Clean the filter every two weeks or more often i...

Page 6: ...cally at a set time 12 Turning off the air conditioner automatically at a set time 12 Canceling the timer setting 12 Setting sleep mode 13 ADVANCED FUNCTIONS 13 Changing room temperature quickly 13 Indoor air purification 13 Auto Clean operation 14 Auto operation 14 Auto Changeover operation 15 Energy saving cooling mode 15 Display screen brightness 15 Operating the air conditioner without the rem...

Page 7: ...et On Off button Signal receiver Operation lamp Air outlet Air deflector Vertical louver Horizontal vane NOTE The number of operation lamps and their locations may vary depending on the model of the air conditioner 7 BEFORE USE ENGLISH Indoor unit The feature can be changed according a type of model The feature can be changed according a type of model ...

Page 8: ...r on off g 7v Indoor fan speed button Adjusts the fan speed f A C D E Operation mode selection button Se lects the operation mode Cooling operation A Auto operation or auto changeover C Dehumidify ing operation D Air circulation E N Jet cooling heating button Warms up or cools down the indoor temperature within a short period of time i Air flow direction button Adjusts the air flow direction verti...

Page 9: ...ose a safe and easily accessible place 2 Fix the holder by fastening the 2 screws firmly with a screwdriver 3 Slide the remote control into the holder Point the remote control towards the signal receiver at the bottom of the air conditioner to operate it NOTE If the display screen of the remote control starts to fade replace the batteries NOTE The remote control may operate other electronic device...

Page 10: ...empera ture The temperature range is 16 C 30 C Removing humidity Dehumidifying operation This mode removes excess moisture from an environment with high humidity or in the rainy season in order to prevent mold from setting in This mode adjusts the room temperature and the fan speed automatically to maintain the optimal level of humidity 1 Press d to turn on the power 2 Press f repeatedly to select...

Page 11: ...ally press i repeatedly and select the desired direction Select H to adjust the direction of the air flow automatically Setting the timer You can use the timer function to save energy and to use the air conditioner more efficiently Setting the current time 1 Press p and hold it for longer than 3 sec onds The AM PM icon flickers at the bottom of the display screen NOTE Adjusting the air flow direct...

Page 12: ...r n to select the timer setting to cancel 3 Press p To cancel all timer settings press p Setting sleep mode Use the sleep mode to turn off the air condi tioner automatically when you go to sleep 1 Press d to turn on the power 2 Press l 3 Press o or q to select the hour up to 7 hours 4 Press p to finish T is displayed on the display screen in sleep mode NOTE In the Cooling and Dehumidifying modes t...

Page 13: ...temperature of 30 C for 30 minutes Indoor air purification Auto Clean operation In the cooling and dehumidifying operations moisture is generated inside the indoor unit Use the auto cleaning function to remove such moisture 1 Press d to turn on the power 2 Press c J is displayed on the display screen If you turn off the power the fan oper ates for 30 minutes and cleans the inside of the indoor uni...

Page 14: ...rtificial intelligence In this mode the fan speed and the tempera ture adjust automatically based on the room temperature 1 Press d to turn on the power 2 Press f repeatedly to select auto opera tion 3 Press o or q to select the desired oper ation code if the temperature is higher or lower than the desired temperature NOTE This function may not be supported depending on the model Code Description ...

Page 15: ... air conditioner without the remote control You can use the On Off button of the indoor unit to operate the air conditioner when the remote control is unavailable However the fan speed is set to high 1 Open the front cover Lift up both sides of the cover slightly 2 Press the On Off button For cooling and heating models the oper ation mode changes depending on the room temperature For cooling only ...

Page 16: ...e unit will beep twice and the lamp will blink 6 times To re enable the function press the On Off button and hold it for 6 seconds The unit will beep twice and the blue lamp will blink 4 times Restarting the air conditioner automatically When the air conditioner is turned on again after a power failure this function restores the previous settings This function is a factory de fault setting 1 Open ...

Page 17: ...r 3M Multi protection filter CAUTION Turn off the power and unplug the power cord before you perform any maintenance other wise it may cause electric shock Never use water that is hotter than 40 C when you clean the filters It may cause deforma tion or discoloration Never use volatile substances when you clean the filters They may damage the surface of the product Do not washed the 3M filter with ...

Page 18: ...lt to remove wash the filter in lukewarm water with detergent 5 Dry the filter in the shade Cleaning the 3M Multi protec tion filter 1 Turn off the power and unplug the power cord 2 Open the front cover and remove the air filter see Cleaning air filter 3 Pull out the 3M Multi protection filter 4 Use a vacuum cleaner to remove dirt Do not wash the 3M Multi Protection Filter with water because the f...

Page 19: ...he service center Water leaks from the indoor unit even when the humidity level is low The power cord is damaged or generating excessive heat A switch a circuit breaker safety ground or a fuse is not operated properly The air conditioner does not work The air conditioner is unplugged Check whether the power cord is plugged into the outlet A fuse is blown or the power supply is blocked Replace the ...

Page 20: ... burner while the air conditioner is in operation Air circulation opera tion is selected In the air circulation operation air blows from the air conditioner without cooling or heating the indoor air Switch the opera tion mode to the cooling operation It is not possible to adjust the fan speed The auto operation jet operation or dehu midifying operation is selected In some operation modes such as t...

Page 21: ... 10 10 92 Un Amigo Siempre Contigo Servicio Técnico online AmigoLG1 www lg com ec Dirección Gye Av Carlos Julio Arosemena km 2 solar 32 Dirección Uio Av De los Shyris N43 139 y Río Coca Síguenos en LGEcuador LGEcuador ...

Reviews: