INSTALLATION GUIDE AT THE SEASIDE
ENGLISH
Sea wind
Sea wind
• Air conditioners should not be installed
in areas where corrosive gases, such as
acid or alkaline gas, are produced.
• Do not install the product where it could
be exposed to sea wind (salty wind)
directly. It can result corrosion on the
product. Corrosion, particularly on the
condenser and evaporator fins, could
cause product malfunction or inefficient
performance.
• If outdoor unit is installed close to the
seaside, it should avoid direct exposure
to the sea wind. Otherwise it needs
additional anticorrosion treatment on the
heat exchanger.
CAUTION
!
INSTALLATION GUIDE
AT THE SEASIDE
- It should be strong enough like concrete to
prevent the sea wind from the sea.
- The height and width should be more than
150 % of the outdoor unit.
- More than 70 cm of space should be kept
between outdoor unit and the windbreak for
easy air flow.
Place with fluent water draining
- Install at a place with fluent water draining to
prevent damage from localized heavy rain
and avoid frequent flooded area.
In case, to install the outdoor unit on the
seaside, set up a windbreak not to be
exposed to the sea wind
In case, to install the outdoor unit on the
seaside, set If the outdoor unit is to be
installed close to the seaside, direct exposure
to the sea wind should be avoided.
Install the outdoor unit on the opposite side of
the sea wind direction. a windbreak not to be
exposed to the sea wind.
Selecting the location (Outdoor Unit)
• Periodic ( more than once/year )
cleaning of the dust or salt particles
stuck on the heat exchanger by using
water.
Sea wind
Windbreak