Outdoor Installation.
5
Therma V R32 Installation Instructions.
• Prepare a strong and level base.
• Place on 3 anti vibration feet, & anchor to base.
• Ensure the unit is 300mm from the wall.
• The flow & return connections are 1” male.
• Fit flexi hoses, full bore isolation valves, on the back of the unit.
• Recommend:-
Additional 400 micron “Y” strainer, external
(with isolation vales on either side)
• Use a through wall insulation kit, this allows for thermal insulation within the wall.
• All pipework to be 28mm copper or 32mm multi layer composite pipe.
• Allow for condensate to feed into a soakaway, tray or soil stack.
• Recommend:-
Magnetic Cleaner & Flow Setter.
• Water volume:- 25L for single fan unit, 50L for double fan unit(Buffer Tank - 4 Port)
Summary of Contents for Therma V R32