DHW Installation
32
Therma V R32 Installation Instructions.
• Remove lid/top of unit (
5, 7 & 9kW units only
).
• Feed the DHW water tank sensor into the back of the unit, shown in the diagram.
• Connect the red connector to the main PCB( Top right hand side of unit)
Terminal CN_TH4, the 7
th
terminal down, from the top right.
• Insert copper sensor into dry pocket tube of cylinder.
• The sensor can be cut and extended, cable no bigger than 0.75mm
2
.
Summary of Contents for Therma V R32
Page 1: ...R32 Monobloc April 2020 Installation Instructions Therma V R32 Generation 3 ...
Page 22: ...Installation Wiring 22 Therma V R32 Installation Instructions DHW 2 Heat Pumps 12 14 16kW ...
Page 26: ...26 Therma V R32 Installation Instructions Installation Wiring Relay Example ...
Page 27: ...27 Therma V R32 Installation Instructions Installation Wiring Relay Example ...
Page 31: ...Central Controller 31 Therma V R32 Installation Instructions ...
Page 37: ...Configuration Installer Setting 37 Therma V R32 Installation Instructions ...