![LG THERMA V HA031M E1 Installation Manual Download Page 10](http://html.mh-extra.com/html/lg/therma-v-ha031m-e1/therma-v-ha031m-e1_installation-manual_213304010.webp)
10
INSTALLATION METHOD
ENGLISH
Terminal Block Information
Symbols used below pictures are as follows :
- L, L1, L2 : Live (230 V AC)
- N : Neutral (230 V AC)
- BR : Brown , WH : White , BL : Blue , BK : Black
How to Connect Sensor to Unit
①
Find Backup Heater Terminal Block KIT.
②
Install the Terminal Block KIT after checking the hole for screw.
③
Plug it to ‘E/Heater Out’ (White Connector) of CN_TH3 in the Main PCB (Unit).
④
Connect cable between the unit and the Backup Heater.
⑤
Use the cord clamper to fix the cable through low voltage hole.
Terminal
Block 1
Terminal
Block 2
Terminal
Block 1
Terminal
Block 2
Low
voltage
Connection Cable
Backup
Heater
Sensor Cable
(Terminal Block KIT)
Sensor Cable
(Terminal Block KIT)
E/Heater Out
(Unit)
Terminal Block 1 (In Backup Heater)
Terminal Block KIT (In Unit)
7
8
A
E/HEATER OUT
SENSOR
(5V DC)
B
31
32
A
E/HEATER OUT
SENSOR
(5V DC)
B
ڸ
ں
ڻ
ڹ
ڼ
< 3 kW >
< 6 kW >
1,MFL68681815,영어 2018. 9. 22. 오전 8:26 페이지 10