background image

Outdoor Unit
SP302CE 

UV2

SP302CE 

UV4

SP362CE 

UV4

SP342CE 

NV2

P/NO : MFL67735111

OWNER’S MANUAL

Please read this manual carefully before operating
your set and retain it for future reference.

TYPE : WALL MOUNTED
MODELS
Indoor Unit
SP302CE 

NV2

SP302CE 

NV4

SP362CE 

NV4

SP342CE 

NV2

AIR

CONDITIONER

www.lg.com

ENGLISH

ESP

AÑOL

Summary of Contents for SP302CE NV2

Page 1: ...NV2 P NO MFL67735111 OWNER S MANUAL Please read this manual carefully before operating your set and retain it for future reference TYPE WALL MOUNTED MODELS Indoor Unit SP302CE NV2 SP302CE NV4 SP362CE NV4 SP342CE NV2 AIR CONDITIONER www lg com ENGLISH ESPAÑOL ...

Page 2: ...nstalled in accordance with national regulations for electrical installations Do not cool excessively indoors This may be harmful for your health and may consume more electricity Block sunlight with blinds or curtains while you are operating the air conditioner Keep doors or windows closed tightly while you are operating the air conditioner Adjust the direction of the air flow vertically or horizo...

Page 3: ...orrectly rated breaker or fuse There is risk of fire or electric shock Do not modify or extend the power cable If the power cable or cord has scrathes or skin peeled off or deteriorated then it must be replaced There is risk of fire or electric shock For installation removal or reinstall always contact the dealer or an Authorized Service Center There is risk of fire electric shock explosion or inj...

Page 4: ...Oxygen deficiency could occur and hence harm your health Do not open the front grille of the product during operation Do not touch the electrostatic filter if the unit is so equipped There is risk of physical injury electric shock or product failure If strange sounds smell or smoke comes from product Immediately turn the breaker off or disconnect the power supply cable There is risk of electric sh...

Page 5: ...talling the product Sharp edges could cause injury If the refrigerant gas leaks during the repair do not touch the leakaing refrigerant gas The refrigernat gas can cause frostbite cold burn Do not tilt the unit when removing or uninstalling it The condensed water inside can spill Do not mix air or gas other than the specified refrigerant used in the system If air enters the refriger ant system an ...

Page 6: ...et time 13 Turning off the air conditioner automatically at a set time 13 Canceling the timer setting 13 Setting sleep mode 14 ADVANCED FUNCTIONS 14 Changing room temperature quickly 14 Indoor air purification 14 Auto Clean operation 15 Smoke Away operation Optional 15 Auto operation Optional 16 Auto Changeover operation Optional 16 C F Conversion 16 Energy saving cooling mode 16 Display screen br...

Page 7: ...nections use only a genuine adapter available from most local hardware stores Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity con nection To disconnect the power cord from the adapter use one hand on each to avoid damaging the ground terminal Avoid frequently unplugging the power cord as this can lead to eventual ground terminal dama...

Page 8: ...uver Air Outlet Horizontal Vane Front Panel 3M Multi Protection Filter or Triple Filter Optional 3M Micro Protection Filter Optional NOTE The number of operation lamps and their locations may vary depending on the model of the air conditioner Indoor unit The feature can be changed according to type of model The feature can be changed according to type of model BEFORE USE Components ...

Page 9: ...on Warms up or cools down the indoor temperature within a short period of time J G Functions button Sets the special functions J Auto clean G Operates energy saving cooling G Adjusts the brightness of the indoor unit display R F Smoke Away button Purifies the air by removing particles that enter the in door unit 4 Air circulation button Used to circu late the room air without cooling or heating DE...

Page 10: ...ose a safe and easily accessible place 2 Fix the holder by fastening the 2 screws firmly with a screwdriver 3 Slide the remote control into the holder Point the remote control towards the signal receiver at the bottom of the air conditioner to operate it NOTE If the display screen of the remote control starts to fade replace the batteries NOTE The remote control may operate other electronic device...

Page 11: ...emperature range is 16 C 60 F 30 C 86 F Removing humidity Dehumidifying operation This mode removes excess moisture from an environment with high humidity or in the rainy season in order to prevent mold from setting in This mode adjusts the room temperature and the fan speed automatically to maintain the optimal level of humidity 1 Press to turn on the power 2 Press f repeatedly to select the dehu...

Page 12: ...ir flow automatically 2 To adjust the direction of the air flow verti cally press E repeatedly and select the desired direction Select I to adjust the direction of the air flow automatically Setting the timer You can use the timer function to save energy and to use the air conditioner more efficiently Setting the current time 1 Press p and hold it for longer than 3 sec onds The AM PM icon flickers...

Page 13: ...lect the hour up to 7 hours 4 Press p to finish T is displayed on the display screen in sleep mode NOTE In the Cooling and Dehumidifying modes the temperature increases by 1 C after 30 minutes and by a further 1 C after another 30 minutes for a more comfortable sleep The temperature increases with up to 2 C from the preset temperature CAUTION The air condition will not operate if cur tains doors o...

Page 14: ... cooling and dehumidifying operations moisture is generated inside the indoor unit Use the auto cleaning function to remove such moisture 1 Press O J is displayed on the display screen If you turn off the power the fan oper ates for 30 minutes and cleans the inside of the indoor unit NOTE Powerful Cooling H P Model Powerful Heating Option is excluded Enable in Cooling Dehumidfying Heating Operatio...

Page 15: ...er 2 Press f repeatedly to select auto opera tion 3 Press G or H to select the desired oper ation code if the temperature is higher or lower than the desired temperature NOTE You can use this function by pressing R without turning the air conditioner on Both the plasma lamp and the cooling lamp light up while Smoke Away is in operation This function may not be supported de pending on the model Cod...

Page 16: ... desired temper ature The temperature range is 18 C 64 F 30 C 86 F 4 Press g repeatedly to select the fan speed C F Conversion The unit converses from C to F or from F to C if Room Temperature KEY is pressed for 5 seconds Energy saving cooling mode This mode minimizes power consumption dur ing cooling and increases the set temperature to the optimal level for a more comfortable en vironment The te...

Page 17: ...the cover slightly 2 Press the On Off button and hold it for 6 seconds The unit will beep twice and the lamp will blink 6 times To re enable the function press the On Off button and hold it for 6 seconds The unit will beep twice and the blue lamp will blink 4 times The feature can be changed according to type of model The feature can be changed according to type of model ON OFF button Room temp Se...

Page 18: ...chnician 3M Micro Protection Filter Optional 3M Multi Protection Filter or Triple Filter Optional Dual Protection Filter CAUTION Turn off the power and unplug the power cord before you perform any maintenance other wise it may cause electric shock Never use water that is hotter than 40 C 104 F when you clean the filters It may cause deformation or discoloration Never use volatile substances when y...

Page 19: ...ilter 4 Use a vacuum cleaner to remove dirt Do not wash the 3M Multi Protection Filter and Triple Filter with water because the filter can be damaged Cleaning the 3M Micro Protection Filter Optional 1 Turn off the power and unplug the power cord 2 Open the front cover and remove the air filter see Cleaning air filter 3 Pull out the 3M Micro Protection Filter 4 Use a vacuum cleaner to remove dirt D...

Page 20: ...r Water leaks from the indoor unit even when the humidity level is low The power cord is damaged or generating excessive heat A switch a circuit breaker safety ground or a fuse is not operated properly The air conditioner does not work The air conditioner is unplugged Check whether the power cord is plugged into the outlet A fuse is blown or the power supply is blocked Replace the fuse or check if...

Page 21: ...ner while the air conditioner is in operation Air circulation opera tion is selected In the air circulation operation air blows from the air conditioner without cooling or heating the indoor air Switch the opera tion mode to the cooling operation It is not possible to adjust the fan speed The auto operation jet operation or dehu midifying operation is selected In some operation modes such as the j...

Page 22: ...22 ENGLISH ...

Page 23: ... 10 10 92 Un Amigo Siempre Contigo Servicio Técnico online AmigoLG1 www lg com ec Dirección Gye Av Carlos Julio Arosemena km 2 solar 32 Dirección Uio Av De los Shyris N43 139 y Río Coca Síguenos en LGEcuador LGEcuador ...