4. TROUBLE SHOOTING
- 86 -
START
Does waveform at
R112 and R114
fluctuate?
NO
Replace main board
YES
Is CN601 connected
properly?
NO
YES
Receiver will work properly.
Is receiver connected
Properly?
YES
Reassemble CN601
NO
Resoldering receiver
SETTING : After initialize Agilent 8960, Test EGSM, DCS mode
Set the property of audio as PRBS or continuous wave. Set the receiving volume of mobile as Max.
Checking Flow