background image

10

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS 

READ ALL INSTRUCTIONS BEFORE USE 

CAUTION

These instructions are only valid if the following country code is on the appliance. If this code is not present on 

the appliance, it is necessary to refer to the technical instructions which will provide the necessary information 

concerning the modification of the appliance to the condition of use for the country Before installation, check that 

the local distribution conditions, nature of gas and pressure, and the adjustment of the appliance are compatible.

•  the method of connection and the installation regulations in the country where the appliance is to be installed 

(if such regulations exist); also the ventilation dimensions shall be given for the purposes of installation in those 

countries where there are no appropriate regulations.

WARNING

 

Never stop a tumble dryer before the end of the drying cycle unless 

all items are quickly removed and spread out so that the heat is 

dissipated.

SAvE ThESE INSTRUCTIONS

Summary of Contents for RV1329C7P

Page 1: ... Inc All Rights Reserved MFL67863731 Rev 01_050919 ENGLISH INDONESIAN Before beginning installation read these instructions carefully this will simplify installation and ensure that the dryer is installed correctly and safely leave these instructions near the dryer after installation for future reference ...

Page 2: ...tup 28 6 Special price ending time setup 29 7 Regular priced dryer cycle time 30 8 Special priced dryer cycle time 31 9 Value of coin 1 32 10 Value of coin 2 Set up for top off price and e suds coin pulse 33 11 Top off time 34 12 Beep volume 35 13 Time to keep the coin Use only for coin type 36 14 How to enter the tyPE 37 Programming Mode Test Mode 37 1 Lqc1 38 2 Factory reset EEPt 39 3 Time Set U...

Page 3: ...quiet operation and an energy saving system ARTISTIC DESIGN Modern front panel look and big clear glass door make your dryer look stylish EASY OF USE An entire selection of user friendly functions makes operating the dryer easy ULTRA CAPACITY The larger drum enables better tumbling and less tangling and wrinkling of the laundry ...

Page 4: ... words mean DANGER You will be killed or seriously injured if you don t immediately follow instructions Warning You can be killed or seriously injured if you don t follow instructions caution You may be slightly injured or cause damage to the product if you do not follow instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell...

Page 5: ...il acetone alcohol petrol kerosene spot removers turpentine waxes and wax removers should be washed in hot water with an extra amount of detergent before being dried in the tumble dryer Items such as foam rubber latex foam shower caps waterproof textiles rubber backed articles and clothes or pillows fitted with foam rubber pads should not be dried in the tumble dryer Fabric softeners or similar pr...

Page 6: ...bjects substances from the machine including the pump and inlet hose filter for example grit nails bra wires and buttons etc Replace fuses in or correct wiring or correct house plumbing Correction of unauthorized repairs Incidental or consequential damage to personal property caused by possible defects with this appliance If the product is installed outside the normal service area any cost of tran...

Page 7: ...hock or injury to persons when using this appliance follow basic precautions including the following Properly ground dryer to conform with all governing codes and ordinances Follow details in the installation instructions Electric shock can result if the dryer is not properly grounded Before use the dryer must be properly installed as described in this manual Electric shock can result if the dryer...

Page 8: ...uctwork inside the dryer cabinet or for exhausting to the outside Use of plastic or other combustible ductwork can cause a fire Punctured ductwork can cause a fire if it collapses or becomes otherwise restricted in use or during installation Ductwork is not provided with the dryer and you should obtain the necessary ductwork locally The end cap should have hinged dampers to prevent backdraft when ...

Page 9: ...to follow these instructions can create an electric shock hazard and or a fire hazard The dryer should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires Never unplug your dryer by pulling on t...

Page 10: ...he country Before installation check that the local distribution conditions nature of gas and pressure and the adjustment of the appliance are compatible the method of connection and the installation regulations in the country where the appliance is to be installed if such regulations exist also the ventilation dimensions shall be given for the purposes of installation in those countries where the...

Page 11: ...e Electric Dryer Specification Please refer to the rating label regarding detailed information Rating 220 240V 50Hz Size 686 mm W x 764 mm D x 983 mm H Single Dryer 686 mm W x 764 mm D x 1954 mm H Stack Dryer Capacity 10 kg Weight 59 4 kg Specifications subject to change by manufacturer NOTE ...

Page 12: ...12 INTRODUCING YOUR DRYER Control panel features OPL type 1 2 4 3 1 Display LED 2 Cycle button 3 Start Pause button 4 Status LED ...

Page 13: ...edium heat Low Temp Use for drying synthetic fabrics washable knit fabrics and noiron finishes Low heat No Heat Use for items that require heat free drying such as plastics or rubber Start Pause button The Start LED flashes when the full vend price has been satisfied then the cycle has been chosen or the machine is paused The Start LED flashes when a card is inserted to add time to the current cyc...

Page 14: ...utton has been pressed The card should have enough balance to satisfy increasing time The operating time can be increased to 10 minutes 10p default by adding more coins When the COOL DOWN has been working if time is added it goes back to the DRYING Time can be added up 99 minutes 5 Change cycle You cannot change the cycle while the machine is running But if the door is opened the machine stops tem...

Page 15: ...Temp and Low Temp button at the same time 2 Push the Med Temp button 3 times 3 Push the Start button 4 Display will show How to use button You can change Dryer vend price cycle time and Cycle parameters etc Press button Description High Temp Move to upper level Med Temp Move to the mode in the same level Low Temp Move to the modes in the same level No Heat Start Enter the selected mode If you turn...

Page 16: ...ress High Temp button to move the upper level 3 Press Med Temp or Low Temp button if you want to be at the same level 4 Press Start button to enter the details of Set up Diagnostic Tests mode is to set price value time value and vend type etc consists of line test reset free cycle and kill cycle Is to collect the usage data Structure of Programming mode Do not use It is only used in inspecting the...

Page 17: ... Push the High Temp and Low Temp button at the same time 2 Push the Med Temp button 3 times 3 Push the Start button 4 Display will show is to set price value time value and vend type etc consists of line test reset free cycle and kill cycle Is to collect the usage data Structure of Programming mode Do not use It is only used in inspecting the machine NOTE ...

Page 18: ... available in dryer NOTE Entering set up mode You will see LqC1 Button Display Press the High Temp button Press the Med Temp or the Low Temp button until appears in the display Press the Start button Press the Start button Display previous regular price Press Med Temp or Low Temp button to set regular price The vend price can be set from 0 to 9 90 in 0 1 increments Press the Start button The machi...

Page 19: ...pears in the display Press the Start button Press the Med Temp or the Low Temp button until appears in the display Press the Start button Display previous special price Press Med Temp or Low Temp button to set special price The vend price can be set from 0 to 9 90 in 0 1 increments Press the Start button The machine sets upthe special price then advances to the next process automatically 1 Continu...

Page 20: ...utton until appears in the display Press the Start button Press the Med Temp or the Low Temp button until appears in the display Structure of Content of Special price days apply or not Disabled Add super wash apply or not Select vend type Sense dry apply or not Pre wash apply or not Top off apply or not only for dryer Twin spray apply or not Disable Enable ...

Page 21: ...p or the Low Temp button until appears in the display Press the Start button Display Press the Start button Press Med Temp or Low Temp button and then select or Disable Enable One or the other will display Press the Start button The machine sets up the special price then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to re...

Page 22: ...Display Press the High Temp button Press the Med Temp or the Low Temp button until appears in the display Press the Start button Press the Med Temp or the Low Temp button until appears in the display Press the Start button Display Press the Med Temp or the Low Temp button until appears in the display Press the Start button Press Med Temp or Low Temp button and then select or Coin Card One or the o...

Page 23: ...e Med Temp or the Low Temp button until appears in the display Press the Start button Press Med Temp or Low Temp button and then select or Disable Enable One or the other will display Press the Start button The machine sets up the Top off then advances to the next pro cess automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on ...

Page 24: ...ed Temp or the Low Temp button until appears in the display Press the Start button Press Med Temp or Low Temp button and then select or Disable Enable One or the other will display Press the Start button The machine sets up the Sense dry then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on of...

Page 25: ...1 Button Display Press the High Temp button Press the Med Temp or the Low Temp button until appears in the display Press the Start button Press the Med Temp or the Low Temp button until appears in the display Press the Start button Display Structure of Sunday Monday Tuesday Wednesday Thursday Friday Saturday ...

Page 26: ...appears in the display Press the Start button Display Press the Start button Press Med Temp or Low Temp button and then select or Disable Enable One or the other will display Press the Start button The machine sets up the special price day Sunday then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type T...

Page 27: ...ess the Start button Display previous special price beginning time Press Med Temp or Low Temp button to select time between 0 and 23 Press the Start button The machine sets up the special price beginning time then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pul...

Page 28: ... ending time Press Med Temp or Low Temp button to select time between 1 and 24 Press the Start button The machine sets up the special price ending time then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control panel open 2 Turn...

Page 29: ...he Start button Display previous regular priced dryer cycle time Press Med Temp or Low Temp button to select time between 10 and 99 Press the Start button The machine sets up the regular priced dryer cycle time then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type P...

Page 30: ...elect time between 10 and 99 Press the Start button The machine sets up the special priced dryer cycle time then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control panel open 2 Turn on off toggle switch OPL Coin Type Press Hi...

Page 31: ...n Display previous coin 1 value Press Med Temp or Low Temp button to select value of coin 1 The value can be set fronm 0 to 9 90 in 0 1 increments Press the Start button The machine sets up the value of coin 1 then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pu...

Page 32: ...lue can be set fronm 0 to 9 90 in 0 1 increments Press the Start button The machine sets up the value of coin 2 then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control panel open 2 Turn on off toggle switch OPL Coin Type Pres...

Page 33: ...on Display previous top off time Press Med Temp or Low Temp button to select time between 1 and 30 Press the Start button The machine sets up the top off time then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control panel open...

Page 34: ...play Press the Start button Display previous value Press Med Temp or Low Temp button to select High or Low or Off Press the Start button The machine sets up the beep volume then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Cont...

Page 35: ...in the display Press the Start button Display previous value Press Med Temp or Low Temp button to select time between 1 180 or Disable Press the Start button The machine sets up the time to keep the coin then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the...

Page 36: ...of Product type Currency choice PDA type Card reader type Coin drop type 0 EU EURO 1 EAP Australia 2 ELC USA 3 EPN China 4 KOR Korea 5 EJP Japan 6 ECI Canada 7 GSC Philippines 0 Pharos 1 HP 0 ESD 1 Greenwald 0 ESD Greenwald Munzprufer Signal pulse 50ms 1 Korea Signal pulse 100ms Pay means card or coin type Default type is coin type If you want to change coin type to card type you need to setup ven...

Page 37: ...mp button Press No Heat button Version and code of machine 7 time Test ends LqC1 During check if the door is open Door switch Motor Heater Off Buzzer beeps seven times dE The door is open Please close the door completely During check if the door is closed Test goes back at step 2 Motor on Heater Off Measured moisture value 70 239 During LqC1 test if no buttons are pressed for 4 minutes machine wil...

Page 38: ...s the Start button then factory reset is done is displayed 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control panel open 2 Turn on off toggle switch OPL Coin Type Push High Temp Low Temp and the 3 Dryer default value for CARD COIN machine Drying time 50 Minute Top off...

Page 39: ... advances to the next process automatically Press Med Temp or Low Temp button to select day between 01 and 31 Press the Start button The machine sets up the day then advances to the next process automatically Press Med Temp or Low Temp button to select hour between 00 and 23 Press the Start button The machine sets up the hour then advances to the next process automatically Press Med Temp or Low Te...

Page 40: ...ears in the display Press the Start button Press the Med Temp button until appears in the display Press the Start button Display will show Select the course you desire In case of dryer card type it has to insert the cash card after removing the service card Then press the cycle course and the start button It is only applicable to the dryer s card type specially and there is no subtraction in card ...

Page 41: ...n until appears in the display Press the Start button Press the Med Temp button until appears in the display Press the Start button Display with beeping Go back to ready mode Insert cycle kill card Descriptions Display Display the current time and Display with beeping Go back to ready mode OPL type Dryer machine will end the cycle by opening the door NOTE ...

Page 42: ...le in dryer It can t enter 5 dELC Dryer Moisture Sense dELC is not available in dryer It can t enter 6 ItrC Interval Regular Cycles Number of Regular cycles 0 65535 7 ItCC Interval Regular Cold Cycles ItCC is not available in dryer It can t enter 8 ItAC Interval Regular Warm Cycles ItAC is not available in dryer It can t enter 9 ItHC Interval Regular Hot Cycles ItHC is not available in dryer It ca...

Page 43: ... 31 Actl Accumulated Total Income Amount of money for Total Income 0 00 65535 32 IttC Interval Total Cycles Number of Total cycles 0 65535 33 ACtC Accumulated Total Cycles Number of Total cycles 0 65535 34 SCPr Super Cycle Price Scpr is not available in dryer It can t enter 35 toPr Top Off Price 0 00 9 90 36 Itd Interval Money Amount of money for regular cycle 0 65535 37 ACd Accumulated Money Amou...

Page 44: ...onal stainless steel cleaner used according to the manufacturer s specifications Never use steel wool or abrasive cleansers they can scratch or damage the surface Cleaning Around and Under the Dryer Vacuum lint and dust from around the dryer and underneath it regularly Vent ductwork should be checked for lint buildup and cleaned at least once per year If any noticeable reduction in airflow or dryi...

Page 45: ...de bracket 2 sliding pad 4 screw 10 machine screw 8 1 Sliding bracket 3 Stacking kit Stacking kit is provided in the upper dryer Stacking kit includes the stacking bracket 1 security bracket 3 bolt 1 screw 6 2 Sliding pad 3 Screw 4 Machine screw The machine can be stacked only on the model designated as suitable by LGE Do not stack the washer on the top You can order the parts for stacking from Qu...

Page 46: ...and the rear of the lower washer in the same position Push the upper dryer matching the slide stacking bracket to make upper and lower front parallel Install the stacking bracket at the rear of the stacked dryer and washer Assemble the six 6 screw to fix the lower washer and upper dryer Please refer to Service Manual for detail to explain the how to stack and fix the machine NOTE ...

Page 47: ...50 Minutes Cool Down Time Cycle 2 Minutes High Temperature 154 4 F 68 C Medium Temperature 140 F 60 C Low Temperature 125 6 F 52 5 C Top Off Time Minutes per coin 10 Minutes Coin 1 Value 0 1 Coin 2 Value 0 1 Minutes Minutes and seconds Minutes Fahrenheit Celsius Celcius Error Mode On PROBLEM POSSIBLE CAUSE SOLUTION It is displayed when thermistor is opened or shorted Thermistor should be replaced ...

Page 48: ...re of the Product to perform during power failures and interruptions or inadequate electrical service 3 Damage or failure caused by leaky or broken water pipes frozen water pipes restricted drain lines inadequate or interrupted water supply or inadequate supply of air 4 Damage or failure resulting from running the Product in a corrosive atmosphere or contrary to the instructions outlined in the Pr...

Page 49: ......

Page 50: ......

Page 51: ...a hak cipta di lindungi INDONESIAN Sebelum memulai pemasangan baca petunjuk ini dengan saksama Petunjuk ini akan mempermudah pemasangan dan memastikan bahwa mesin pengering terpasang dengan benar dan aman Simpan petunjuk ini di dekat mesin pengering setelah pemasangan sebagai referensi di kemudian hari ...

Page 52: ...ga spesial 29 7 Waktu siklus mesin pengering dengan harga reguler 30 8 Waktu siklus mesin pengering dengan harga reguler 31 9 Nilai koin 1 32 10 Nilai koin 2 Mempersiapkan untuk top off harga dan e suds koin nadi 33 11 Waktu pengisian penuh 34 12 Volume bunyi alarm 35 13 Waktu untuk menyimpan koin Digunakan hanya untuk tipe koin 36 14 Cara memasukkan Tipe tyPE 37 MODE PEMROGRAMAN MODE UJI 37 1 Lqc...

Page 53: ...bih hemat energi DESAIN YANG ARTISTIK Tampilan panel depan yang modern dan pintu kaca bening yang jernih membuat mesin pengering Anda terlihat bergaya MUDAH DIGUNAKAN Seluruh pilihan fungsi yang mudah digunakan memudahkan pengoperasian pengering KAPASITAS ULTRA Drum yang lebih besar memungkinkan penggulingan lebih baik dan meminimalkan kusut dan keriput pada cucian ...

Page 54: ...AN Kata kata tersebut berarti BAHAYA Anda akan kehilangan nyawa atau mengalami cedera parah jika Anda tidak segera mengikuti petunjuk PERINGATAN Anda dapat kehilangan nyawa atau mengalami cedera parah jika Anda tidak mengikuti petunjuk PERHATIAN Anda mungkin akan mengalami cedera ringan atau menyebabkan kerusakan pada produk jika Anda tidak mengikuti petunjuk Semua pesan keselamatan akan memberi t...

Page 55: ...hkan secara berkala oleh petugas servis berpengalaman Jangan memasang atau menyimpan mesin pengering di tempat yang terkena cuaca Selalu periksa bagian dalam mesin pengering apakah ada benda asing Bersihkan saringan tiras sebelum atau sesudah pengeringan Jangan mengeringkan barang yang belum dicuci dalam mesin pengering Barang yang kotor oleh zat seperti minyak goreng aseton alkohol bensin minyak ...

Page 56: ... dari mesin termasuk filter pompa dan filter selang saluran masuk misalnya pasir paku kawat bra dan kancingnya dsb Mengganti sekering pada rangkaian kabel atau pemasangan yang benar atau pemasangan pipa rumah yang benar Koreksi atas perbaikan yang tidak resmi Kerusakan yang tidak disengaja atau konsekuensial terhadap barang pribadi yang disebabkan oleh kemungkinan cacat pada mesin ini Jika produk ...

Page 57: ...ada mesin pengering dengan benar agar sesuai dengan semua aturan peraturan dan tata cara yang berlaku Ikuti perincian dalam petunjuk pemasangan Sengatan listrik dapat terjadi jika mesin pengering tidak dipasangi arde dengan benar Sebelum digunakan mesin pengering harus dipasang dengan benar seperti yang dijelaskan dalam buku panduan ini Sengatan listrik dapat terjadi jika mesin pengering tidak dip...

Page 58: ... atau untuk saluran pembuangan ke luar Penggunaan pipa berbahan plastik atau bahan yang mudah terbakar lainnya dapat menyebabkan kebakaran Pipa yang bolong dapat menyebabkan kebakaran jika runtuh atau terbatas saat digunakan atau saat pemasangan Pipa tidak disediakan bersama mesin pengering dan Anda harus memperoleh pipa yang diperlukan dari lokasi setempat Tutup ujung harus memiliki peredam beren...

Page 59: ...Kelalaian dalam mengikuti petunjuk ini dapat menimbulkan bahaya sengatan listrik dan atau bahaya kebakaran Mesin pengering harus selalu disambungkan ke stopkontak listrik masing masing yang memiliki nilai voltase yang sesuai dengan label spesifikasi Ini akan memberikan kinerja terbaik dan juga agar tidak terjadi kelebihan beban pada rangkaian kabel rumah yang dapat menyebabkan bahaya kebakaran aki...

Page 60: ...egara tersebut Sebelum pemasangan periksa apakah kondisi distribusi setempat sifat gas dan tekanan dan penyetelan sudah kompatibel Metode sambungan dan peraturan pemasangan di negara tempat mesin dipasang jika ada peraturan semacam itu juga dimensi ventilasi harus diberikan untuk keperluan pemasangan di negara negara yang tidak memiliki peraturan yang sesuai PERINGATAN Jangan sekali kali menghenti...

Page 61: ...V1329C7P Tipe Mesin Pengering Listrik Spesifikasi Silakan lihat label spesifikasi mengenal informasi terperinci Catu Daya 220 240V 50Hz Ukuran 686 mm P x 764 mm L x 983 mm T Single Dryer 686 mm P x 764 mm L x 1954 mm T Stack Dryer Kapasitas 10 kg Berat 59 4 kg Spesifikasi dapat diubah oleh produsen CATATAN ...

Page 62: ...12 MEMPERKENALKAN MESIN PENGERING ANDA Fitur panel kontrol Tipe OPL 1 2 4 3 1 Tampilan LED 2 Tombol Siklus 3 Tombol Start Pause 4 LED Status ...

Page 63: ... sedang Low Temp Gunakan untuk mengeringkan kain sintetis kain rajutan yang dapat dicuci dan permukaan yang tidak boleh disetrika Panas rendah No Heat Gunakan untuk barang yang membutuhkan pengeringan bebas panas seperti plastik atau karet Tombol Start Pause LED Start berkedip saat harga vending penuh sudah dilunasi kemudian siklus telah dipilih atau mesin dijeda LED Start berkedip saat kartu dima...

Page 64: ... dari sisa waktu selalu untuk bagian pendinginan CATATAN 4 Pengisian penuh Untuk menambahkan lebih banyak waktu Setelah kartu debit dimasukkan waktu pengoperasian dapat dinaikkan menjadi 10 menit 10p standar bila tombol Start atau tombol siklus yang dipilih telah ditekan Kartu harus memiliki saldo yang cukup untuk memenuhi waktu yang ditambahkan Waktu pengoperasian dapat ditingkatkan menjadi 10 me...

Page 65: ...ecara bersamaan 2 Tekan tombol Med Temp 3 kali 3 Tekan tombol Start 4 Tampilan akan menampilkan Cara menggunakan tombol Anda dapat mengubah harga vending Mesin pengering waktu siklus dan parameter Siklus dsb Tekan tombol Deskripsi High Temp Pindah ke tingkat atas Med Temp Pindah ke mode pada tingkat yang sama Low Temp Pindah ke mode pada tingkat yang sama No Heat Start Masukkan mode yang dipilih J...

Page 66: ...gh Temp untuk pindah ke tingkat yang lebih tinggi 3 Tekan tombol Med Temp atau Low Temp jika Anda ingin berada pada tingkat yang sama 4 Tekan tombol Start untuk memasukkan detail Penyiapan atau Uji Diagnostik adalah untuk menetapkan nilai harga nilai waktu tipe vending dsb terdiri atas uji saluran pengaturan ulang siklus gratis dan penghentian siklus adalah mengumpulkan data pemakaian Struktur mod...

Page 67: ... 1 Tekan tombol High Temp and Low Temp secara bersamaan 2 Tekan tombol Med Temp 3 kali 3 Tekan tombol Start 4 Tampilan akan menampilkan adalah untuk menetapkan nilai harga nilai waktu tipe vending dsb erdiri atas uji saluran pengaturan ulang siklus gratis dan penghentian siklus adalah mengumpulkan data pemakaian Struktur mode pemrograman Jangan menggunakan Hanya digunakan dalam memeriksa mesin CAT...

Page 68: ...g rgHP harga panas biasa tidak tersedia di pengering CATATAN Masuk ke mode penyiapan Anda akan melihat LqC1 Tombol Tampilan Tekan tombol High Temp Tekan tombol Med Temp atau Low Temp sampai muncul di layar Tekan tombol Start Tekan tombol Start Menampilkan harga reguler sebelumnya Tekan tombol Med Temp atau Low Temp untuk mengatur harga reguler Harga vending dapat diatur mulai 0 9 90 dalam pertamba...

Page 69: ...Temp sampai muncul di layar Tekan tombol Start Tekan tombol Med Temp atau Low Temp sampai muncul di layar Tekan tombol Start Menampilkan harga spesial sebelumnya Tekan tombol Med Temp atau Low Temp untuk mengatur harga spesial Harga vending dapat diatur mulai 0 9 90 dalam pertambahan 0 1 Tekan tombol Start Mesin akan menyiapkan harga spesial lalu maju ke proses berikutnya secara otomatis 1 Lanjutk...

Page 70: ...cul di layar Tekan tombol Start Tekan tombol Med Temp atau Low Temp sampai muncul di layar Struktur dari Isi Isi dari Hari harga spesial berlaku atau tidak Nonaktifkan Add super wash berlaku atau tidak Pilih tipe vending Tidak tersedia Pra cuci berlaku atau tidak Pengisian penuh berlaku atau tidak hanya untuk pengering Twin Spray berlaku atau tidak Nonaktifkan Aktifkan ...

Page 71: ...ed Temp atau Low Temp sampai muncul di layar Tekan tombol Start Menampilkan Tekan tombol Start Tekan tombol Med Temp atau Low Temp lalu pipih atau Nonaktifkan Aktifkan Satu atau yang lain akan ditampilkan Tekan tombol Start Mesin memasang harga spesial lalu maju ke proses berikutnya secara otomatis 1 Lanjutkan untuk menyiapkan mode berikutnya 2 Hentikan perubahan nilai penyiapan dan kembali ke mod...

Page 72: ...pan Anda akan melihat LqC1 Tombol Tampilan Tekan tombol High Temp Tekan tombol Med Temp atau Low Temp sampai muncul di layar Tekan tombol Start Tekan tombol Med Temp atau Low Temp sampai muncul di layar Tekan tombol Start Menampilkan Tekan tombol Med Temp atau Low Temp sampai muncul di layar Tekan tombol Start Tekan tombol Med Temp atau Low Temp lalu pilih atau Tipe koin Tipe Kartu Satu atau yang ...

Page 73: ...p atau Low Temp sampai muncul di layar Tekan tombol Start Tekan tombol Med Temp atau Low Temp lalu pilih atau Nonaktifkan Aktifkan Satu atau yang lain akan ditampilkan Tekan tombol Start Mesin akan menyiapkan tipe Vending lalu maju ke proses berikutnya secara otomatis 1 Lanjutkan untuk menyiapkan mode berikutnya 2 Hentikan perubahan nilai penyiapan dan kembali ke mode siap Tipe koin Alihkan sakela...

Page 74: ...w Temp sampai muncul di layar Tekan tombol Start Tekan tombol Med Temp atau Low Temp lalu pilih atau Nonaktifkan Aktifkan Satu atau yang lain akan ditampilkan Tekan tombol Start Mesin akan menyiapkan Sensor dry lalu maju ke proses berikut nya secara otomatis 1 Lanjutkan untuk menyiapkan mode berikutnya 2 Hentikan perubahan nilai penyiapan dan kembali ke mode siap Tipe koin Alihkan sakelar ke nyala...

Page 75: ...pan Anda akan melihat LqC1 Tombol Tampilan Tekan tombol High Temp Tekan tombol Med Temp atau Low Temp sampai muncul di layar Tekan tombol Start Tekan tombol Med Temp atau Low Temp sampai muncul di layar Tekan tombol Start Menampilkan Struktur dari Minggu Senin Selasa Rabu Kamis Jumat Sabtu ...

Page 76: ...uncul di layar Tekan tombol Start Menampilkan Tekan tombol Start Tekan tombol Med Temp atau Low Temp lalu pilih atau Nonaktifkan Aktifkan Satu atau yang lain akan ditampilkan Tekan tombol Start Mesin akan menyiapkan hari harga spesial Minggu lalu maju ke proses berikutnya secara otomatis 1 Lanjutkan untuk menyiapkan mode berikutnya 2 Hentikan perubahan nilai penyiapan dan kembali ke mode siap Tipe...

Page 77: ...enampilkan waktu awal harga spesial sebelumnya Tekan tombol Warm atau Cold untuk memilih waktu antara 0 dan 23 Tekan tombol Start Mesin akan menyiapkan waktu mulai harga spesial lalu maju ke proses berikutnya secara otomatis 1 Lanjutkan untuk menyiapkan mode berikutnya 2 Hentikan perubahan nilai penyiapan dan kembali ke mode siap Tipe koin Alihkan sakelar ke nyala mati Tipe kartu Keluarkan kartu l...

Page 78: ... Tekan tombol Warm atau Cold untuk memilih waktu antara 1 dan 24 Tekan tombol Start Mesin akan menyiapkan waktu akhir harga spesial lalu maju ke proses berikutnya secara otomatis 1 Lanjutkan untuk menyiapkan mode berikutnya 2 Hentikan perubahan nilai penyiapan dan kembali ke mode siap Tipe koin Alihkan sakelar ke nyala mati Tipe kartu Keluarkan kartu layanan Tipe susun 1 Panel kontrol terbuka 2 Al...

Page 79: ... siklus mesin pengering dengan harga reg uler Tekan tombol Med Temp atau Low Temp untuk memilih waktu antara 10 dan 99 Tekan tombol Start Mesin akan menyiapkan waktu siklus mesin pengering dengan harga reguler lalu maju ke proses berikutnya secara otomatis 1 Lanjutkan untuk menyiapkan mode berikutnya 2 Hentikan perubahan nilai penyiapan dan kembali ke mode siap Tipe koin Alihkan sakelar ke nyala m...

Page 80: ...art Mesin akan menyiapkan waktu siklus mesin pengering dengan harga spesial lalu maju ke proses berikutnya secara otomatis 1 Lanjutkan untuk menyiapkan mode berikutnya 2 Hentikan perubahan nilai penyiapan dan kembali ke mode siap Tipe koin Alihkan sakelar ke nyala mati Tipe kartu Keluarkan kartu layanan Tipe susun 1 Panel kontrol terbuka 2 Alihkan sakelar ke nyala mati Tipe OPL Koin Tekan High Tem...

Page 81: ...ebelumnya Tekan tombol Med Temp atau Low Temp untuk memilih nilai koin 1 Nilai dapat diatur mulai 10 1000 dalam pertamba han 10 Tekan tombol Start Mesin akan menyiapkan nilai koin 1 lalu maju ke proses berikutnya secara otomatis 1 Lanjutkan untuk menyiapkan mode berikutnya 2 Hentikan perubahan nilai penyiapan dan kembali ke mode siap Tipe koin Alihkan sakelar ke nyala mati Tipe kartu Keluarkan kar...

Page 82: ... dalam pertamba han 10 Tekan tombol Start Mesin akan menyiapkan nilai koin 2 lalu maju ke proses berikutnya secara otomatis 1 Lanjutkan untuk menyiapkan mode berikutnya 2 Hentikan perubahan nilai penyiapan dan kembali ke mode siap Tipe koin Alihkan sakelar ke nyala mati Tipe kartu Keluarkan kartu layanan Tipe susun 1 Panel kontrol terbuka 2 Alihkan sakelar ke nyala mati Tipe OPL Koin Tekan High Te...

Page 83: ...umnya Tekan tombol Med Temp atau Low Temp untuk memilih waktu antara 1 dan 30 Tekan tombol Start Mesin akan menyiapkan waktu pengisian penuh lalu maju ke proses berikutnya secara otomatis 1 Lanjutkan untuk menyiapkan mode berikutnya 2 Hentikan perubahan nilai penyiapan dan kembali ke mode siap Tipe koin Alihkan sakelar ke nyala mati Tipe kartu Keluarkan kartu layanan Tipe susun 1 Panel kontrol ter...

Page 84: ...pilkan nilai sebelumnya Tekan tombol Med Temp atau Low Temp untuk memilih High atau Low atau Off Tekan tombol Start Mesin akan menyiapkan volume suara alarm lalu maju ke proses berikutnya secara otomatis 1 Lanjutkan untuk menyiapkan mode berikutnya 2 Hentikan perubahan nilai penyiapan dan kembali ke mode siap Tipe koin Alihkan sakelar ke nyala mati Tipe kartu Keluarkan kartu layanan Tipe susun 1 P...

Page 85: ...l Start Menampilkan nilai sebelumnya Tekan tombol Med Temp atau Low Temp untuk memilih tombol guna memilih waktu antara 0 180 Tekan tombol Start Mesin akan menyiapkan waktu untuk menyimpan koin lalu maju ke proses berikutnya secara otomatis 1 Lanjutkan untuk menyiapkan mode berikutnya 2 Hentikan perubahan nilai penyiapan dan kembali ke mode siap Tipe koin Alihkan sakelar ke nyala mati Tipe kartu K...

Page 86: ...ang Tipe PDA Tipe pembaca kartu Tipe koin drop 0 EU EURO 1 EAP Australia 2 ELC USA 3 EPN China 4 KOR Korea 5 EJP Japan 6 ECI Canada 7 GSC Philippines 0 Pharos 1 HP 0 ESD 1 Greenwald 0 ESD Greenwald Munzprufer Signal pulse 50ms 1 Korea Signal pulse 100ms Bayar berarti Tipe kartu atau koin Tipe standar adalah Tipe koin Jika Anda ingin mengubah Tipe koin ke Tipe kartu Anda perlu mengatur tipe vend di...

Page 87: ...bol Low Temp Tekan tombol No Heat Versi dan kode mesin 7 kali Tes berakhir LqC1 Saat memeriksa pintu terbuka Sakelar pintu Motor Heater Off Buzzer berbunyi bip tujuh kali dE Pintunya terbuka Silakan tutup pintu sepenuhnya Saat memeriksa pintu terbuka Test kembali pada langkah 2 Motor on Heater Off lai kelembaban terukur 70 239 Selama uji LqC1 jika tidak ada tombol yang ditekan selama 4 menit mesin...

Page 88: ...maka pengembalian ke pengaturan pabrik selesai ditampilkan 1 Lanjutkan untuk menyiapkan mode berikutnya 2 Hentikan perubahan nilai penyiapan dan kembali ke mode siap Tipe koin Alihkan sakelar ke nyala mati Tipe kartu Keluarkan kartu layanan Tipe susun 1 Panel kontrol terbuka 2 Alihkan sakelar ke nyala mati Tipe OPL Koin Tekan High Temp dua kali Nilai standar pengering untuk mesin KARTU KOIN Waktu ...

Page 89: ...lalu maju ke proses berikutnya secara otomatis Tekan tombol Med Temp atau Low Temp untuk memilih hari antara 01 dan 31 Tekan tombol Start Mesin akan menyiapkan hari lalu maju ke proses berikutnya secara otomatis Tekan tombol Med Temp atau Low Temp untuk memilih jam antara 00 dan 23 Tekan tombol Start Mesin akan menyiapkan jam lalu maju ke proses berikutnya secara otomatis Tekan tombol Med Temp ata...

Page 90: ...sampai muncul di layar Tekan tombol Start Tekan tombol Med Temp atau Low Temp sampai muncul di layar Tekan tombol Start Layar akan menunjukkan Tekan tombol Start Dalam kasus tipe kartu pengering kartu kredit harus dimasukkan setelah itu mengeluarkan kartu layanan Kemudian tekan kursus siklus dan tombol start Ini hanya berlaku untuk jenis kartu pengering khususnya dan tidak ada pengurangan saldo ka...

Page 91: ... sampai muncul di layar Tekan tombol Start Tekan tombol Med Temp sampai muncul di layar Tekan tombol Start Menampilkan disertai bunyi alarm Kembali ke mode siap Masukkan kartu penghentian siklus Deskripsi Tampilan Tampilkan waktu sekarang dan Menampilkan disertai bunyi alarm Kembali ke mode siap Tipe OPL Mesin pengering akan mengakhiri siklus dengan membuka pintu CATATAN ...

Page 92: ...idak tersedia di pengering Tidak bisa masuk 5 dELC Sensor Kelembapan Pengering dELC tidak tersedia di pengering Tidak bisa masuk 6 ItrC Interval Siklus Reguler Jumlah Siklus Reguler 0 65535 7 ItCC Interval Siklus Delicates Reguler ItCC tidak tersedia di pengering Tidak bisa masuk 8 ItAC Interval Warm Cold Reguler ItAC tidak tersedia di pengering Tidak bisa masuk 9 ItHC Interval Siklus Hot Reguler ...

Page 93: ...umulasi Total Penghasilan Jumlah uang untuk Total Penghasilan 0 00 65535 32 IttC Interval Total Siklus Jumlah Total siklus 0 65535 33 ACtC Akumulasi Total Siklus Jumlah Total siklus 0 65535 34 SCPr Harga Siklus Super Scpr tidak tersedia pada mesin pengering Tidak bisa dimasukkan 35 toPr Harga Pengisian Penuh 0 00 9 90 36 Itd Interval Uang Jumlah uang untuk siklus reguler 0 65535 37 ACd Akumulasi U...

Page 94: ...embersih baja tahan karat konvensional yang digunakan sesuai dengan spesifikasi produsen Jangan sekali kali menggunakan wol baja atau pembersih abrasif karena dapat menggores atau merusak permukaan Membersihkan di Sekitar dan di Bawah Pengering Sedot tiras dan debu menggunakan penyedot debu dari sekitar mesin pengering dan di bawahnya secara teratur Pipa ventilasi harus diperiksa apakah ada penump...

Page 95: ...kup braket geser 2 bantalan geser 4 sekrup 10 sekrup mesin 8 1 Braket geser 2 Bantalan geser 3 Sekrup 4 Sekrup mesin 3 Kit penyusunan Kit penyusunan disediakan di pengering atas Kit penyusunan mencakup braket penyusun 1 braket pengaman 3 baut 1 sekrup 6 1 Braket penyusun 2 Baut 3 Sekrup 4 Braket pengaman Mesin hanya dapat disusun pada model yang didesain oleh LGE Jangan menyusun mesin cuci di bagi...

Page 96: ... bawah pada posisi yang sama Dorong mesin pengering atas yang cocok dengan braket geser penyusunan agar bagian depan atas dan bawah menjadi sejajar Pasang braket penyusun di bagian belakang mesin pengering dan mesin cuci yang disusun Pasang 6 enam sekrup untuk mengencangkan posisi mesin cuci bawah dan mesin pengering atas Lihat Buku Panduan Servis untuk perincian mengenai cara menyusun dan mengenc...

Page 97: ... Ini ditampilkan ketika sensor kelembaban rusak Periksa sensor kelembaban dan PCB PEMULIHAN KEGAGALAN DAYA Jika terjadi kegagalan daya mesin akan berhenti beroperasi tetapi tampilan waktu tetap menyala yang menunjukkan waktu sesaat sebelum terjadi kegagalan daya Tekan tombol Start setelah daya hidup kembali maka mesin akan dinyalakan ulang DEFAULT DRYER SETTINGS Pengaturan awal Awal Waktu Siklus M...

Page 98: ... atau layanan listrik yang tidak memadai 3 Kerusakan atau kegagalan yang disebabkan oleh pipa air yang bocor atau rusak pipa air yang beku saluran pem buangan yang terhalang suplai air yang tidak memadai atau terganggu atau suplai udara yang tidak memadai 4 Kerusakan atau kegagalan akibat mengoperasikan Produk di lingkungan yang korosif atau bertentangan dengan petunjuk yang diuraikan dalam buku p...

Page 99: ......

Page 100: ... BC 31 ABCD Jl Sultan Iskandar Muda Kebayoran Lama Utara Kebayoran Lama Jakarta Selatan DKI Jakarta Raya Indonesia TANDA PENDAFTARAN PETUNJUK PENGGUNAAN MANUAL DAN KARTU JAMINAN GARANSI DALAM BAHASA INDONESIA BAGI PRODUK ELEKTRONIK Nomor I 14 LEI4 02220 0419 ...

Reviews: