10
INSTALLATION
Specifications
Asterisk(s) means model variant and can be varied (0-9) or (A-Z).
Installation Place
Requirements
Before installing the appliance, check the following
information to make sure that the appliance
should be installed in a correct place.
Installation Location
WARNING
• Do not install the appliance around a heat
source. The rear side of the appliance must be
well ventilated. Failure to follow these
instructions may result in problems.
• The appliance is not designed for maritime use
or for use in mobile installation such as caravans,
aircraft and etc.
• Do not install the appliance as a built-in
appliance. It is not suitable for built-in purpose.
NOTE
• For better drying performance, keep the rear of
the appliance away from the wall.
• Make sure that the location where the appliance
will be installed meets a minimum clearance
conditions.
• Install the appliance on a flat hard floor.
Allowable slope under the appliance is 1 degree.
• Never try to correct any unevenness in the floor
with pieces of wood, cardboard or similar
materials under the appliance.
• Install the appliance in a location where service
engineers are easily accessible in the event of a
breakdown.
• Do not install the appliance next to high-
temperature appliances such as refrigerator,
oven or stove, and etc. It can cause poor drying
performance and delay programme duration. It
also adversely affect the proper functioning of
the compressor.
• Do not install the appliance where there is a risk
of frost or dust. The appliance may not be able to
operate properly or may be damaged by
freezing of condensed water in the pump and
drain hose.
• With the appliance installed, adjust all four feet
using a spanner to ensure the appliance is
stable, and a clearance of approximately 20 mm
is left between the top of the appliance and the
underside of any work-top.
Ventilation
• Alcove or under counter
- Ensure airflow of 3.17 m
3
/mm through the
appliance.
Model
RC90V9*V2W
Power supply
220-240 V~, 50 Hz
Dimension (Width X Depth X Height)
600 mm X 690 mm X 850 mm
Product weight
56 kg
Allowable temperature
5 - 35
℃
5 cm
1 cm
1 cm
Summary of Contents for RC90V9 V2W Series
Page 44: ...Memo ...
Page 65: ...21 UTILISATION FRANÇAIS g I s allume pendant le lavage du condenseur Description ...
Page 92: ...Note ...
Page 140: ......