LG PVRCUSZ0 Owners & Installation Manual Download Page 2

Safety Precaution

Owner’s & Installation Manual 

3

2

Weekly Wired Remote Controller 

Weekly Wired Remote Controller Owner’s & Installation Manual

TABLE OF CONTENTS

Safety Precaution

.............................................................................................3~4

Part Description

................................................................................................5~6

Installation instruction

.........................................................................................7

Remote controller connection method

...............................................................8

Address setup of central control

........................................................................9

Cooling operation

...............................................................................................10

Standard cooling  ................................................................................................10

Power cooling .....................................................................................................11

Heating operation

...............................................................................................12

Temperature control

...........................................................................................13

Setting desired temperature................................................................................13

The room temperature confirmation ....................................................................13

Fan Speed operation

.........................................................................................14

Fan Speed selector .............................................................................................14

Air flow direction control ......................................................................................14

Additional functions

...........................................................................................15

Auto operation.....................................................................................................15

Dehumidification operation .................................................................................16

Fan operation  .....................................................................................................16

Setting current time  ............................................................................................17

Setting preset for weekly time .............................................................................18

Setting holiday.....................................................................................................19

On preset ............................................................................................................20

Off preset ............................................................................................................20

Usage restriction function....................................................................................21

Auto restarting Function  .....................................................................................21

Self diagnosis fuction  .........................................................................................21

Different mode operation.....................................................................................22

Be sure to request to the
service center or installation
specialty store when
installing products.

• It will cause fire or electric shock

or explosion or injury.

Request to the service center
or installation specialty store
when reinstalling the
installed product.

• It will cause fire or electric shock

or explosion or injury.

Do not disassemble, fix, and
modify products randomly.

• It will cause fire or electric shock.

Do not place flammable
stuffs close to the product.

• It will cause fire.

Do not allow water to run
into the product.

• It will cause electric shock or

breakdown.

Do not give the shock to the
product.

• It will cause breakdown when

giving the shock to the product.

Installation

Safety Precaution

• The installation requires expert skills, and it should be installed by the service center or other shops specialized

in the installation and recognized by our company.

• For all the problems arising after installation by someone who has no relevant qualifications, our company will

not provide free service.

• The following safety cautions are provided to prevent unexpected dangers or losses.

: If the user does not follow the mandatory items, it may result in serious injury or death.

: If the user does not follow the mandatory items, it may cause personal injury or property

damage.

: Warning and Caution are to call the user’s attention to the possible danger. Read and follow

them carefully in order to prevent a safety accident.

: Warning and Caution are indicated in this guide and the product itself to help protect the users

from danger.

WARNING

CAUTION

WARNING

In-use

HI
MED
LO

ZONE

1 2

3 4

Time

Program set

Time

r

On
Set no.

Time

Off

01

03

05

07

09

11

13

15

17

19

Oper

ation unit

JET

Heater

Defro

st

Preheat
Humidify

Filter

Out do

or

Room Tem

p

AUTO SWING

OPERATION

SET TE

MP

FAN SPE

ED

SUB FUNCTION

AUTO

21

23

HI
MED
LO

ZONE

1 2

3 4

Time

Program 

set

Time

r

On
Set no.

Time

Off

01

03

05

07

09

11

13

15

17

19

Oper

ation unit

JET

Heater

Defro

st

Preheat
Humidify

Filter

Out door

Room Te

mp

AUTO SWING

OPERATION

SET TE

MP

FAN SPE

ED

SUB FUNCTION

AUTO

21

23

HI

MED

LO

ZONE

1

2

3

4

Tim

e

Pro

gram set

Tim

er

On
Set

 no.

Time

Of

f

01

03

05

07

09

11

13

15

17

19

Opera

tion unit

JET

Heater
Defrost Preheat

Humidify

Filter

Out door

Ro

om T

emp

AUTO SWING

OPERATION

SET TE

MP

FAN SPE

ED

SUB FUNCTION

AUTO

21

23

HI
MED
LO

ZONE

1 2

3 4

Time

Program set

Time

r

On
Set no.

Time

Off

01

03

05

07

09

11

13

15

17

19

Opera

tion unit

JET

Heater

Defro

st

Prehea

t

Humidify

Filter

Out do

or

Room T

emp

AUTO SWING

OPERATION

SET TE

MP

FAN SPE

ED

SUB FUNCTION

AUTO

21

23

HI
MED
LO

ZONE

1 2

3 4

Time

Program set

Time

r

On
Set no.

Time

Off

01

03

05

07

09

11

13

15

17

19

Operation un

it

JET

Heater

Defro

st

Preheat
Humidify

Filter

Out door

Room T

emp

AUTO SWING

OPERATION

SET TE

MP

FAN SPE

ED

SUB FUNCTION

AUTO

21

23

Summary of Contents for PVRCUSZ0

Page 1: ...completely before installing the product Installation work must be performed in accordance with the national wiring standards by authorized personnel only Please retain this owner s installation manual for future reference after reading it thoroughly Owner s Installation Manual Models PVRCUSZ0 ...

Page 2: ...company For all the problems arising after installation by someone who has no relevant qualifications our company will not provide free service The following safety cautions are provided to prevent unexpected dangers or losses If the user does not follow the mandatory items it may result in serious injury or death If the user does not follow the mandatory items it may cause personal injury or prop...

Page 3: ...e Off 01 03 05 07 09 11 13 15 17 19 Operatio n unit JET Heater Defrost Preheat Humidify Filter Out door Room Temp AUTO SWING OPERA TION SET TEMP FAN SPEED SUB FUNCTIO N AUTO 21 23 HI MED LO ZONE 1 2 3 4 Time Program set Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 Operatio n unit JET Heater Defrost Preheat Humidify Filter Out door Room Temp AUTO SWING OPERA TION SET TEMP FAN SPEED SUB FU...

Page 4: ...witch on the back of the wired remote controller to the required condition of the product Especially if the switch exclusively for air conditioning and air conditioning heating selection switch is incorrectly set it can cause a problem to the product operation CAUTION Part Description Information of slide switch CVT TYPE Room Temp Sensing Remo Indoor Unit 2TH Remo Indoor Low Standard High Single G...

Page 5: ...control is consisted by group number and number of indoor unit Multi model Connect the outdoor unit and P1485 of outdoor unit Single model Connect P1485 of outdoor unit When you connect the indoor unit with central control unit you should setup Network address which is recognized by central control unit inside of indoor unit The address of central control is consisted by group number and number of...

Page 6: ...kes the room cool using pleasant and fresh air Room Temp Room Temp Operation unit Set no Time Program set MED LO Timer On Time Off 01 03 05 07 09 11 13 15 17 19 21 23 ZONE 1 2 3 4 AUTO JET Heater Defrost Preheat Humidify Filter Out door AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION HI ZONE 1 2 3 4 Time Program set Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 Operation unit M...

Page 7: ...than the room temperature Fix the desired temperature higher than the room temperature You can select the desired temperature for cooling operation from 16 C to 37 C and heating operation from 16 C to 30 C Heating operation Room Temp Room Temp Operation unit Set no Time Program set MED LO Timer On Time Off 01 03 05 07 09 11 13 15 17 19 21 23 ZONE 1 2 3 4 AUTO JET Heater Defrost Preheat Humidify Fi...

Page 8: ...ically or horizontally if you press the vertical air flow direction button or horizontal air flow direction button Room Temp Operation unit Set no Time Program set Timer On Time Off 01 03 05 07 09 11 13 15 17 19 21 23 ZONE 1 2 3 4 JET Heater Defrost Preheat Humidify Filter Out door AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION MED LO AUTO HI 2ndF PLASMA Timer Program Hour Cancel Week Holida...

Page 9: ... is changed by pressing the button Fix the current day 4Press the reset button on the control part of remote control It sets up when you press the reset button once and performs the cancel function when you press the button once more Room Temp AUTO Operation unit Set no Time Program set Timer On Time Off 01 03 05 07 09 11 13 15 17 19 21 23 ZONE 1 2 3 4 JET Heater Defrost Preheat Humidify Filter Ou...

Page 10: ...time Ex If you want to operate at Monday from 6 to 8 and from 13 to 22 Room Temp Time AUTO ZONE 1 2 3 4 JET Heater Defrost Preheat Humidify Filter Out door HI MED LO Operation unit Set no Timer On Time Off AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION Program set 01 03 05 07 09 11 13 15 17 19 21 23 Program set Time HI MED LO AUTO Room Temp ZONE 1 2 3 4 Timer On Set no Time Off Operation uni...

Page 11: ...on unit Program set Room Temp Time AUTO ZONE 1 2 3 4 JET Heater Defrost Preheat Humidify Filter Out door HI MED LO Set no Time AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION Timer On Off 2ndF PLASMA Timer Program Hour Cancel Week Holiday Set Clr Min RESET 01 03 05 07 09 11 13 15 17 19 21 23 Operation unit Program set Room Temp Time AUTO ZONE 1 2 3 4 JET Heater Defrost Preheat Humidify Filter...

Page 12: ...unit operate heating Mode while several indoor units are operating Cooling Mode Outdoor segment and Cooling segment are blinking like screen on the left It is display to operate cooling in outdoor unit 2 If one indoor unit operate Cooling or Dehumidification Mode while several indoor units are operating Heating Mode Outdoor segment and Cooling segment are blinking It is display to operate Heating ...

Page 13: ...P No 3828A20860Q Printed in Korea After reading this manual keep it in a place easily accessible to the user for future reference ...

Reviews: