background image

2

1

E

n

g

li

s

h

EMPTYING THE WATER COLLECTION TANK

Drain

Cap

Drain Outlet

When the internal water collection tank is full, FL
will appear in the display and the air conditioner

will turn off until the tank is emptied.

Unplug the air conditioner, disconnect
the exhaust hose from the back, and move
the air conditioner to a suitable drain
location or outdoors. You may also place
a pan under the drain that will hold up
to 1 quart of water.

Remove the drain cap and the rubber plug

from the drain outlet.

Once the water collection tank is drained,
reinstall the rubber plug and the drain cap,

making sure it is on securely.

Place the air conditioner in the desired
location, reconnect the exhaust hose, and
plug in the air conditioner.

NOTES:

‡

When turned on after being unplugged, the air
conditioner will automatically reset to COOL
mode, with a temperature setting of 

2

.

1

2

3

4

Using the bottom drain port

5

6

7

 end of the hose a suitable

drain location or outdoors.

8

Note:

 If the water full alarm is often on, there may 
 be some malfunction about the unit. 

          Contact the professional service for help.

FL apperars in the display

 The water collection tank is full, drain the tank and reset your setting.

NOTICE

C A R E A N D C L E A R I N G

Summary of Contents for P09UCM0

Page 1: ...OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference P NO MFL65920301 www lg com TYPE PORTABLE AIR CONDITIONER P09UCM0 P12UCM0 ...

Page 2: ...ons 3 4 Electrical Safety 4 6 PARTS AND FEATURES Key Parts and Components 7 Control Panel and Remote 8 HOW TO USE Before Using Your Air Conditioner 9 10 Using the Controls 11 13 INSTALLAT ION INSTRUCTIONS Preparing for Installation 14 Window Vent Panel and Extensions 15 Installation in Vertical Sliding Windows 16 17 Installation in Casement Windows 18 19 TROUBLESHOOTING Before Calling for Service ...

Page 3: ... on the air conditioner Be sure all packaging materials are removed from the air conditioner before use It can result in personal injury Do not disassemble or modify the air conditioner or the power cord It can result in the risk of electric shock or fire Do not place the power cord or air conditioner near a heater radiator or other heat source It can result in the risk of electric shock or fire D...

Page 4: ...ecure the wheels with blocks to prevent the air conditioner from rolling on smooth floors Install the air conditioner on a sturdy level floor capable of supporting up 50 kg 110 lbs Installation on a weak or unlevel floor can result in result in the risk of property damage and personal injury Make sure the air conditioner is the correct size for the area you wish to cool Using an air conditioner th...

Page 5: ...shock Gasolin Plug in the power plug properly Otherwise it will cause electric shock or fire due to heat generation or electric shock Do not operate or stop the unit by inserting or pulling out the power plug It will cause electric shock or fire due to heat generation Do not damage or use an unspecified power cord It will cause electric shock or fire ON Do not modify power cord length It will caus...

Page 6: ...the main power switch when not using it for a long time Prevent accidental startup and the possibility of injury Turn off the power and breaker firstly when cleansing the unit Since the fan rotates at high speed during operation it may cause injury Do not put a pet or house plant where it will be exposed to direct air flow This could injure the pet or plant Do not use this appliance for special pu...

Page 7: ... the diffuser and hose to connect the air conditioner to the window installation kit to vent exhaust air outside FILTER You can pull out and insert the filter easily HANDLES The handles provide a convenient grip when lifting the air conditioner SWIVELING CASTERS Swiveling casters allow you to move the air conditioner easily on most floor surfaces BOTTOM DRAIN PORT Before moving the unit drain the ...

Page 8: ... PART shows the active mode COOL FAN DRY and ENERGY SAVER Auto clean Water full and Timer TEMP TIMER Use these buttons to adjust the set temperature up or down or to adjust the timer delay time TIMER Allows you to set a delay from 1 to 24 hours that will turn the air conditioner on or off automatically 5 1 4 9 2 7 8 Operation of functions is the same when using the remote or the control panel unle...

Page 9: ...iods of time To prevent damage or injury to pets and plants make sure they are not exposed to direct airflow from the air conditioner When used at the same time as stoves fireplaces and other combustion devices make sure there is a sufficient flow of fresh air into the room Do not use in tightly enclosed spaces with these types of devices This air conditioner is intended for household use as a con...

Page 10: ...nstall the provided AAA batteries Press and glide the battery cover on the back of the remote then you can remove the cover Insert two new alkaline AAA batteries into the battery compartment being sure to note the proper polarity Reattach the battery cover making sure the locking tab clicks into place NOTES Use only alkaline batteries Do not use rechargeable batteries When replacing batteries alwa...

Page 11: ...the remote and the sensor Press the MODE button to select the operating mode COOL FAN DRYor ENERGY SAVER for the air conditioner And you can see the active mode through the LCD Display The default setting is COOL Press the MODE button to change to FAN press again to change to DRY again to change to ENERGY SAVER and again to return to COOL MODE USING THE CONTROLS Mode Features COOL Compressor runs ...

Page 12: ...tomatically turn OFF or turn ON after a delay of up to 24 hours The display will show 0 Use the buttons to adjust the delay time from 1 to 24 hours in one hour increments To set an automatic off delay press the TIMER button while the air conditioner is running and use the buttons to adjust the delay time The air conditioner will automatically turn OFF after the set delay To set an automatic on del...

Page 13: ...ns with the compressor off for a few minutes after the power is turned off To cancel AUTO CLEAN or to stop an AUTO CLEAN cycle in process simply press the AUTO CLEAN button again The AUTO CLEAN function will not operate if the air conditioner is already off AUTO CLEAN 1 2 AUTO SWING function can only be activated with the remote When this function is on the air discharge will oscillate to circulat...

Page 14: ...s are used for window venting Not all components are used for every installation EXHAUSTCOMPONENTS Window Installation Kit includes 2 Window Vent Panel and 2 Extension Panels Flexible Venting Hose Diffuser 14 10 Type A Screws Security Bracket 4 Type A Screws 1 Type B Foam Seal non adhesive 2 Type A Foam Seals adhesive Vent Panel Large Extension Panel Extension Vent Panel Small Extension Panel 2 Ty...

Page 15: ...dow openings from 740 to 910 mm use the window vent panel and both extension panels Vent Panel Small extension panel Vent Panel 460 mm Vent Panel 460 mmí 610 mm 460 í 610 mm Small extension panel Vent Panel Large extension panel Vent Panel Large extension panel Vent Panel 610 í 740 mm Large extension panel Vent Panel Large extension panel Vent Panel 74 í 91 mm Small extension panel Small extension...

Page 16: ...d Foam seal B Non adhesive type 4 Cut the foam seal B Non adhesive type to the window width Stuff the foam seal B between the glass and the window to prevent air and insects from getting into the room 3 Carefully lower the window Secure the vent panel in place with 4 type B screws plus one screw for each extension Vent panel only 4 type B screws Vent panel and one extension 5 type B screws Vent pa...

Page 17: ...AL SLIDING WINDOWS INSTALLATION INSTRUCTIONS 5 Install the security bracket with a type A screw as shown Type A screw Security Bracket 6 Insert the oval end of the diffuser into the window installation kit until the locking tabs engage ...

Page 18: ...foam seal B between the glass and the window to prevent air and insects from getting into the room Vent Panel Type B screws Carefully close the window Secure the vent panel in place with 4 type B screws plus one screw for each extension Vent panel only 4 type B screws Vent panel and one extension 5 type B screws Vent panel and two extensions 6 type B screws Two vent panels and two extensions 9 typ...

Page 19: ...the diffuser into the window installation kit until the locking tabs engage INSTALLATION INSTRUCTIONS 5 Install the window security bracket with a type A screw as shown Type A screw Security bracket INSTALLATION IN CASEMENT STYLE WINDOWS ...

Page 20: ... filter If the filter is heavily soiled it can be washed in warm water using a mild detergent Do not use harsh cleaners or very hot water Do not wash in a dish asher Allow the filter to dry completely before reinstalling Reinsert the filter making sure that the bottom of the filter is between the tabs and the coil guard Reinstall the filter cover making sure it clips into place 1 2 Your air condit...

Page 21: ... water collection tank is drained reinstall the rubber plug and the drain cap making sure it is on securely Place the air conditioner in the desired location reconnect the exhaust hose and plug in the air conditioner NOTES When turned on after being unplugged the air conditioner will automatically reset to COOL mode with a temperature setting of 22 C 1 2 3 4 Using the bottom drain port 5 6 7 end o...

Page 22: ...cap Remove and clean the filter allow it to dry completely then reinstall it Remove the batteries from the remote Store the air conditioner in a cool dry location away from direct sunlight extreme temperatures and excessive dust Before using the air conditioner again Make sure the filter and drain cap are in place Check the cord to make sure it is in good condition with no cracks or damage Place n...

Page 23: ...rature Adjust the temperature setting if needed Air conditioner does Airflow is restricted Make sure there is sufficient clearance around the not cool properly air conditioner and that the air inlet and outlet are not blocked by furniture curtains etc The air filter is dirty Clean the air filter at least every two weeks See the Care and Cleaning section The room is very hot or not enough When firs...

Page 24: ... Empty the water collection tank See the Care and Cleaning section CH01 Short or open circuit in the indoor Unplug the air conditioner and contact your authorized air thermostat LGservice center CH02 Short or open circuit in the indoor Unplug the air conditioner and contact your authorized pipe thermostat LGservice center CH03 The difference between Evaporator temperature and indoor temperature Un...

Page 25: ...25 ...

Page 26: ...26 ...

Page 27: ...26 ...

Page 28: ......

Reviews: