MULTI V Water IV
Heat Pump
7. Capacity tables
74
Cooling Capacity (30 HP)
Outside Units
Note
1. TC: Total Capacity(kW), PI : Power Input(kW, Comp. + Outdoor fan motor)
2. Capacity tables show the average value of conditions which may occur.
3. By applying the Variable Water Flow Valve Control KIT, the minimum flow rate to 40% is applied. Refer to the Gray colored range.
60
45
115.2
39.3
8.42
42.6
9.77
46.3
11.44
50.4
12.90
51.9
13.19
54.0
13.47
55.5
13.77
144.0
39.3
8.26
42.6
9.63
46.3
11.26
50.4
12.68
51.9
12.97
54.0
13.26
55.5
13.56
288.0
39.3
7.65
42.6
9.05
46.3
10.53
50.4
11.81
51.9
12.13
54.0
12.45
55.5
12.68
360.0
39.3
7.39
42.6
8.84
46.3
10.33
50.4
11.58
51.9
11.90
54.0
12.19
55.5
12.33
432.0
39.3
7.26
42.6
8.74
46.3
10.22
50.4
11.46
51.9
11.78
54.0
12.06
55.5
12.16
50
10
115.2
32.7
1.63
35.4
1.90
38.7
2.28
42.0
2.50
43.2
2.54
45.0
2.65
46.2
2.67
144.0
32.7
1.60
35.4
1.88
38.7
2.24
42.0
2.46
43.2
2.52
45.0
2.60
46.2
2.63
288.0
32.7
1.45
35.4
1.76
38.7
2.08
42.0
2.33
43.2
2.41
45.0
2.40
46.2
2.46
360.0
32.7
1.43
35.4
1.77
38.7
2.02
42.0
2.27
43.2
2.30
45.0
2.38
46.2
2.37
432.0
32.7
1.41
35.4
1.77
38.7
1.98
42.0
2.24
43.2
2.23
45.0
2.37
46.2
2.33
15
115.2
32.7
2.23
35.4
2.60
38.7
3.05
42.0
3.40
43.2
3.49
45.0
3.58
46.2
3.64
144.0
32.7
2.18
35.4
2.56
38.7
3.00
42.0
3.35
43.2
3.43
45.0
3.52
46.2
3.58
288.0
32.7
2.01
35.4
2.39
38.7
2.79
42.0
3.14
43.2
3.23
45.0
3.29
46.2
3.35
360.0
32.7
1.95
35.4
2.36
38.7
2.73
42.0
3.08
43.2
3.14
45.0
3.23
46.2
3.26
432.0
32.7
1.92
35.4
2.34
38.7
2.71
42.0
3.05
43.2
3.10
45.0
3.20
46.2
3.21
20
115.2
32.7
2.76
35.4
3.23
38.7
3.72
42.0
4.20
43.2
4.32
45.0
4.40
46.2
4.49
144.0
32.7
2.71
35.4
3.17
38.7
3.67
42.0
4.13
43.2
4.25
45.0
4.33
46.2
4.42
288.0
32.7
2.50
35.4
2.94
38.7
3.43
42.0
3.87
43.2
3.96
45.0
4.07
46.2
4.13
360.0
32.7
2.41
35.4
2.88
38.7
3.37
42.0
3.81
43.2
3.90
45.0
3.99
46.2
4.04
432.0
32.7
2.37
35.4
2.85
38.7
3.35
42.0
3.78
43.2
3.87
45.0
3.94
46.2
4.00
25
115.2
32.7
3.36
35.4
3.90
38.7
4.55
42.0
5.15
43.2
5.27
45.0
5.38
46.2
5.47
144.0
32.7
3.29
35.4
3.84
38.7
4.48
42.0
5.06
43.2
5.18
45.0
5.29
46.2
5.38
288.0
32.7
3.03
35.4
3.61
38.7
4.19
42.0
4.71
43.2
4.83
45.0
4.95
46.2
5.06
360.0
32.7
2.94
35.4
3.52
38.7
4.10
42.0
4.63
43.2
4.74
45.0
4.86
46.2
4.92
432.0
32.7
2.89
35.4
3.48
38.7
4.06
42.0
4.58
43.2
4.70
45.0
4.81
46.2
4.84
30
115.2
32.7
4.16
35.4
4.83
38.7
5.63
42.0
6.33
43.2
6.48
45.0
6.62
46.2
6.75
144.0
32.7
4.07
35.4
4.74
38.7
5.53
42.0
6.23
43.2
6.37
45.0
6.52
46.2
6.63
288.0
32.7
3.72
35.4
4.42
38.7
5.15
42.0
5.82
43.2
5.93
45.0
6.11
46.2
6.20
360.0
32.7
3.64
35.4
4.33
38.7
5.06
42.0
5.70
43.2
5.85
45.0
5.99
46.2
6.05
432.0
32.7
3.59
35.4
4.29
38.7
5.02
42.0
5.64
43.2
5.80
45.0
5.93
46.2
5.98
35
115.2
32.7
4.60
35.4
5.35
38.7
6.24
42.0
7.01
43.2
7.19
45.0
7.36
46.2
7.48
144.0
32.7
4.51
35.4
5.27
38.7
6.14
42.0
6.89
43.2
7.07
45.0
7.24
46.2
7.36
288.0
32.7
4.16
35.4
4.92
38.7
5.73
42.0
6.46
43.2
6.60
45.0
6.78
46.2
6.89
360.0
32.7
4.04
35.4
4.83
38.7
5.61
42.0
6.34
43.2
6.49
45.0
6.66
46.2
6.72
432.0
32.7
3.99
35.4
4.79
38.7
5.56
42.0
6.28
43.2
6.43
45.0
6.60
46.2
6.63
40
115.2
32.7
5.47
35.4
6.33
38.7
7.40
42.0
8.31
43.2
8.52
45.0
8.72
46.2
8.87
144.0
32.7
5.35
35.4
6.23
38.7
7.27
42.0
8.17
43.2
8.38
45.0
8.58
46.2
8.73
288.0
32.7
4.92
35.4
5.82
38.7
6.78
42.0
7.65
43.2
7.83
45.0
8.03
46.2
8.17
360.0
32.7
4.77
35.4
5.70
38.7
6.66
42.0
7.51
43.2
7.68
45.0
7.88
46.2
7.94
432.0
32.7
4.70
35.4
5.64
38.7
6.60
42.0
7.43
43.2
7.61
45.0
7.81
46.2
7.82
45
115.2
32.7
6.33
35.4
7.30
38.7
8.55
42.0
9.61
43.2
9.85
45.0
10.08
46.2
10.25
144.0
32.7
6.20
35.4
7.19
38.7
8.41
42.0
9.45
43.2
9.69
45.0
9.92
46.2
10.09
288.0
32.7
5.67
35.4
6.72
38.7
7.83
42.0
8.84
43.2
9.05
45.0
9.28
46.2
9.45
360.0
32.7
5.50
35.4
6.57
38.7
7.71
42.0
8.67
43.2
8.87
45.0
9.10
46.2
9.16
432.0
32.7
5.41
35.4
6.50
38.7
7.65
42.0
8.58
43.2
8.78
45.0
9.02
46.2
9.02
Combination
(%)
Inlet Water
Temp. (
)
Water Flow
Rate
[
˜
/min]
Indoor Air Temp. (DB/WB,
)
20
23
26
27
28
30
32
14
16
18
19
20
22
24
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI