5-8
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE
OUTER CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE
HIGH VOLTAGE TRANSFORMER. (SEE PAGE 2-1)
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER
OF WATER IN CONTAINER) IN THE OVEN.
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
TRANSFORMER
(Wire leads removed)
MAGNETRON
(Wire leads removed)
1. Measure the resistance.
(Ohm-meter scale: Rx1 and Rx100)
• Primary winding
• Secondary winding
• Filament winding
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Primary winding to ground
• Filament winding to ground
1. Measure the resistance.
(Ohm-meter scale: Rx1)
• Filament terminal
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Filament to chassis
Approx.: 0.2 ~ 0.4 ohm
Approx.: 60 ~ 90 ohm
Less than: 1 ohm
Normal: Infinite
Normal: Infinite
Normal: Less than 1 ohm
Normal: Infinite
FILAMENT
WINDING
PRIMARY
TERMINAL
COMPONENT TEST PROCEDURE
Summary of Contents for MS-2642FB
Page 26: ...6 1 EXPLODED VIEW INTRODUCTION ...
Page 27: ...6 2 13213A 13552A 15006A 13581A 13536A 14026A 14970A 13352A 13720D DOOR PARTS ...
Page 28: ...6 3 23506A 23572A 268711 WTP018 24781M CONTROLLER PARTS ...
Page 29: ...6 4 36549S WTP013 33390G 34370T WTT010 WTT021 33112U 35889A WTT011 33052M OVEN CAVITY PARTS ...
Page 30: ...6 5 WSZ085 466001 466003 466001 44510A 43500A LATCH BOARD PARTS ...
Page 32: ...6 7 WTT021 63302A 63303A 56170D WSZ002 948503 WTT028 647781 BASE PLATE PARTS ...
Page 33: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Page 34: ...8 2 PRINTED CIRCUIT BOARD ...