5-15
CONDITION
CHECK
RESULT
CAUSE
REMEDY
(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run.
(Display operates properly)
No microwave
oscillation.
No continuity.
Continuity.
Disconnect the
wire leads from
relay 2 and
check continuity
of relay2.
(Operate the unit)
Defective PCB
assembly
Defective high
voltage
transformer.
Replace PCB
assembly
Output is full power
when you set lower
power level.
Abnormal.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
Defective PCB
assembly
Replace PCB
assembly
Replace high
voltage
transformer.
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Abnormal
normal
Check high vol-
tage transformer
Abnormal
normal
Check high vol-
tage capacitor.
Defective high
voltage diode.
Replace high
voltage diode.
Abnormal
normal
Check high vol-
tage diode.
Defective
magnetron.
Replace
magnetron.
Abnormal
Check
Magnetron.
NOTE: • Make sure the wire leads are in the correct position.
• When Removing the wire leads from the parts, be sure to grasp the connector, not the wires.
• When removing the magnetron, be sure to install the magnetron gasket in the correct position
and in good condition.
Summary of Contents for MS-1145KYL
Page 9: ...SCHEMATIC DIAGRAM 4 3 ...
Page 27: ...6 2 DOOR PARTS 13581A 14970A 14026A 13650A WTT028 13552A 13213A 14890A 13551A 13536A EV ...
Page 28: ...6 3 CONTROLLER PARTS 23551A 268711 WTT028 24781M EV ...
Page 29: ...6 4 OVEN CAVITY PARTS 33390G 35889A WTT021 33112U WTP013 36549S 33052A WTT010 EV ...
Page 30: ...6 5 LATCH BOARD PARTS 466001 466003 WSZ085 466001 43500A 43501A EV ...
Page 32: ...6 7 BASE PLATE PARTS 63302A WTT021 WSZ002 56170D EV ...
Page 35: ......