D. PCB ASSEMBLY REMOVAL
1) Remove the control panel assembly from the
cavity. (Refer to control panel assembly removal
on previous page.)
2) Remove screws which hold the PCB SUB ASS’Y to
the control panel.
3) Disconnect the flat cable from the PCB SUB
ASS’Y and take off the PCB SUB ASS’Y
E. DOOR MAIN ASSEMBLY REMOVAL
1) Open the door.
2) Remove the choke cover cap very carefully with a
flat-blade screwdriver.
CAUTION : Be careful not to damage door seal plate
with the screwdriver.
3) Lift up and push the door.
NOTE:
1. After replacing the door, be sure to check that the
primary switch, monitor switch, and secondary switch
operate normally.
2. After replacing the door, check for microwave energy
leakage with a survey meter. Microwave energy must
be below the limit of 4 mW/cm. (with a 275 ml water
load)
3. When mounting the door assembly to the oven
assembly, be sure to adjust the door assembly parallel
to the chassis. Also adjust so the door has no play
between the inner door surface and oven frame
assembly. If the door assembly is not mounted
properly, microwaves may leak from the clearance
between the door and the oven.
5-4
Door seal plate
Key Membrane
Door Open Button Release
Lever
Button Spring
Control Panel
PCB Sub Asm
Remove choke cover cap
Remove door
Spacer
Summary of Contents for MS-1071MC
Page 29: ...6 2 1002 1003 1008 1004 1000 1005 1006 1007 1001 DOOR PARTS ...
Page 30: ...6 3 2003 2004 2005 2000 W140 W032 2006 2001 2002 CONTROL PANEL PARTS ...
Page 31: ...6 4 3006 W101 3023 3002 3021 W081 3014 W094 3024 3025 3013 3020 OVEN CAVITY PARTS ...
Page 33: ...6 6 W067 5001 5002 W067 INTERIOR PARTS ...
Page 34: ...6 7 W067 W106 6002 6002 6009 6004 6001 6005 6006 6008 6007 W067 W101 BASE PLATE PARTS ...
Page 35: ...8 2 PRINTED CIRCUIT BOARD ...
Page 36: ...July 1997 Printed in Korea P NO 3828W5S0547 July 1997 P NO 3828W5S0547 Printed in Korea ...