5-11
COMPONENTS
TEST PROCEDURE
RESULTS
Disconnect the 8 pin
connector from P.C.B.
(Refer to schemetic diagram
on page 4-3)
RELAY 2, RELAY 3
OF P.C.B.
(Wire leads removed.)
Note: Relay
Relay 1: Fan motor
Turntable motor
Oven lamp
Relay 2: Microwave
Relay 3: Grill
FAN MOTOR
(Wire leads removed)
TURNTABLE
MOTOR
(Wire leads removed)
Measure the resistance.
(Ohm-meter scale: R x 1)
Measure the resistance.
(Ohm-meter scale: R x 1000)
Normal:
Abnormal:
∞
or several
Ω
Normal: Approx. 100~200
Ω
Abnormal:
∞
or several
Ω
NOTE : • A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED FOR ANY REASON.
• MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION.
• WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE
CONNECTOR, NOT THE WIRES.
A
B
C
Cooking Start OFF
1
3
5
7
8
Relay 2
Relay 3
Cooking Start OFF
A ~ B A ~ C
30 ~ 50
Ω
300~500
Ω
Summary of Contents for MG-606BL
Page 9: ...SCHEMATIC DIAGRAM 4 3 ...
Page 29: ...6 2 13720D 13350F 13581A 14970A 14026A 13552A 15006A 13213A 14890A DOOR PARTS ...
Page 32: ...6 5 WSZ085 466003 466001 43501A 43500A 466001 LATCH BOARD PARTS ...
Page 34: ...6 7 56170D 63302A 63303A WTT021 WSZ002 WSZ062 WTT030 647781 BASE PLATE PARTS ...
Page 35: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Page 36: ...8 2 PRINTED CIRCUIT BOARD ...
Page 37: ...P NO 3828W5S1325 October 1999 Printed in Korea ...