5-8
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE
OUTER CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE
HIGH VOLTAGE TRANSFORMER. (SEE PAGE 2-1)
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER
OF WATER IN CONTAINER) IN THE OVEN.
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
TRANSFORMER
(Wire leads removed)
MAGNETRON
(Wire leads removed)
1. Measure the resistance.
(Ohm-meter scale: Rx1 and Rx100)
• Primary winding
• Secondary winding
• Filament winding
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Primary winding to ground
• Filament winding to ground
1. Measure the resistance.
(Ohm-meter scale: Rx1)
• Filament terminal
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Filament to chassis
Approx.: 1.4 ohm
Approx.: 90 ohm
Less than: 1 ohm
Normal: Infinite
Normal: Infinite
Normal: Less than 1 ohm
Normal: Infinite
PRIMARY
TERMINAL
SECONDARY
TERMINAL
FILAMENT
WINDING
TERMINAL
COMPONENT TEST PROCEDURE
Summary of Contents for MG-606BL
Page 9: ...SCHEMATIC DIAGRAM 4 3 ...
Page 29: ...6 2 13720D 13350F 13581A 14970A 14026A 13552A 15006A 13213A 14890A DOOR PARTS ...
Page 32: ...6 5 WSZ085 466003 466001 43501A 43500A 466001 LATCH BOARD PARTS ...
Page 34: ...6 7 56170D 63302A 63303A WTT021 WSZ002 WSZ062 WTT030 647781 BASE PLATE PARTS ...
Page 35: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Page 36: ...8 2 PRINTED CIRCUIT BOARD ...
Page 37: ...P NO 3828W5S1325 October 1999 Printed in Korea ...