WIRING CONNECTION
ENGLISH
Connecting cables to the In-
door Unit
- Connect the wires to the terminals on the
control board individually according to the
outdoor unit connection.
* Ensure that the color of the wires of out-
door unit and the terminal No. are the
same as those of indoor unit respectively
- Heatpump Model
Clamping of cables
- Arrange two power cables on the control
panel.
- First, fasten the clamp with a screw to the
inner boss of control panel.
- For the cooling model, fix the other side of
the clamp with a screw strongly.
For connecting cable to the terminal block,
put the 1.0mm2 cable(thinner cable) on the
clamp and tighten it with a plastic clamp to
the other boss of the control panel.
- In Australia, the length of power supply cable
measured from the entry of the power sup-
ply cable to the middle of live pin on the
power plug should be over 1.8m.
19
• Make sure that the screws of the
terminal fixed tightly
• Installation work must be performed in
accordance with the national wiring
standards by authorized personnel only
CAUTION
!
Terminals on the
indoor unit
1(L) 2(N) 3
Terminals on the
outdoor unit
1(L) 2(N) 3
POWER SUPPLY
1Ø 220-240V 50Hz
(220V-240V~)
1(L) 2(N)
BR
BL
GN/YL
Capacity
Mode
Max. Input
Max.
Current
42kBtu/h
48kBtu/h
55kBtu/h
Cooling
6,600 W
28 A
Heating
6,100 W
25 A
Summary of Contents for MFL62541004
Page 38: ......