-25-
Yes
6
No
Yes
No
Failure modes: Heating (No heating / defrosting)
Failure symptoms
- Heating / Defrosting not working
- No microwaves
- Raw/Uncooked food
Safety switch is located at the top of the latch
Check the connection status of the switch
connector and Micro Switch is pressed when
is closed
No Heating
Unplug the power cord
When the contact is closed adjust gap
Normal
Adjust latch
Check start button operation by opening and closing the
door 2~3 times
Unplug the power cord
Check latch contacts
Primary Switch is located on the top of
latch board
Check that the contact is pressed after
the door is closed.
Check latch contacts
Primary Switch is located on the top of
latch board