-26-
Yes
6
7
No
Yes
No
Yes
No
Yes
latch board
Measure the resistance across the switch ends with a multimeter
Normal
Replace Primary
Check connections of the magnetron and measure the resistance across MGT
Normal
Replace
Check the connection of the high voltage transformer, and measure the
Normal
Replace the
high-voltage transformer
Primary Switch is located on the top of
Abnormal
Normal
Normal: Less than 1 Ohm
Magnetron
resistance with a multimeter
measure the resistance across both ends of high voltage fuse with a multimeter
safety Switch
B/W Primary & Core
Normal= Infinity
B/W Filament & Core
Normal= Infinity
B/W Filament Terminals
B/W Filament & Case
Normal: Infinity
Normal: around 1 Ohm
Normal: Around infinity