5-18
(TROUBLE 7) Grill
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Heater is not
operating.
Abnormal.
Normal.
Normal.
Heater.
Thermostat and
relay3.(Grill)
Abnormal.
Malfunction the
thermostat.
Malfunction the
heater.
Replace.
Wire connection.
No continuity.
Open or loosen.
Replace or
connect tightly.
Replace.
1. Lower tempera-
ture the oven.
Abnormal.
Normal.
Heater.
Thermostat and
relay3.(Grill)
Abnormal.
Malfunction the
thermostat.
Malfunction the
heater.
Replace.
Replace.
(TROUBLE 6) Oven does not cook properly when programmed for the set power level
(Operates properly on HIGH)
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Output is full when
you set lower
power level.
Abnormal.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
Defective P.C.B.
assembly.
Replace P.C.B.
assembly.
NOTE: * Make sure the wore leads correct position.
* When removing the wire leads from parts be sure to grasp the connector not the wires.
* When removing the magnetron, be sure to install the magnetron gasket in the correct position and in
good condition.
Summary of Contents for MC-8082WRS
Page 9: ...SCHEMATIC DIAGRAM 4 3 ...
Page 30: ...6 2 13536A 13581A 14970A 14026A 13552A 13213A 14890A 13720D 15006A DOOR PARTS ...
Page 31: ...6 3 268711 24781S 23790D 23572A 250202 249401 250201 249402 250203 WTP015 CONTROL PANEL PARTS ...
Page 33: ...6 5 466001 43500A 44510A 466001 43501A WSZ085 466003 LATCH BOARD PARTS ...
Page 35: ...6 7 WTT021 63302A 63303A 56170D WSZ002 WTT030 647781 BASE PLATE PARTS ...
Page 36: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Page 37: ...8 2 PRINTED CIRCUIT BOARD ...