5-3
MEASUREMENT OF MICROWAVE POWER OUTPUT
DISASSEMBLY AND ADJUSTMENT
A. OUTER CASE REMOVAL
1) Disconnect the power supply cord from the outlet.
2) Remove the screws from the rear and along side
edges of the case.
The outer case must be moved backward to be lifted
off.
B. POWER SUPPLY CORD
1) Remove the outer case.
2) Disconnect two terminals, and remove one screw of
the earth terminal.
CAUTION: DISCHARGE THE HIGH VOLTAGE
CAPACITOR BEFORE SERVICING
(refer to page 2-1)
C. CONTROL PANEL ASSEMBLY
1) Disconnect the leadwire from the PCB SUB ASS’Y.
2) Remove the screws for the earth and securing the
control panel.
3) Lift control panel ASS’Y from the oven by the tab
unhooked.
• Microwave power output measurement is made with
the microwave oven supplied at its rated voltage and
operated at its maximum microwave power setting with
a load of (1000±5) g of potable water.
• The water is contained in a cylindrical borosilicate glass
vessel having a maximum material thickness of 3 mm
and an outside diameter of approximately 190mm.
• The oven and the empty vessel are at ambient
temperature prior to the start of the test.
• The initial temperature (T1) of the water is (10±2)°C It
is measured immediately before the water is added to
the vessel. After addition of the water to the vessel,
the load is immediately placed on the center of the
turntable which is in the lowest position and the
microwave power switched on.
• The time T for the temperature of the water to rise by a
value
∆
T of (10±2)°K is measured, where T is the time
in seconds and
∆
T is the temperature rise. The initial
and final water temperatures are selected so that the
maximum difference between the final water
temperature and the ambient temperature is 5°K.
• The microwave power output P in watts is calculated
from the following formula :
is measured while the microwave generator is
operating at full power. Magnetron filament heat-up
time is not included. (about 3 sec)
• The water is stirred to equalize temperature throughout
the vessel, prior to measuring the final water
temperature.
• Stirring devices and measuring instruments are
selected in order to minimize addition or removal of
heat.
WATER LOAD
TURNTABLE
P =
• T
2
: Temperature after heating
• T
0
: Temperature after bown
• M: Weight of bowl
4187 x (
∆
T) + 0.55 X (T
2
- T
0
) X M
T
Summary of Contents for MB-4322AH
Page 9: ...4 3 SCHEMATIC DIAGRAM ...
Page 27: ...6 2 13581A 14970A 14026A 13552A 13536A 15006A 13213A 13720D 13352A DOOR PARTS ...
Page 28: ...6 3 23572A 249402 26549T 24781T WTP015 249401 CONTROL PANEL PARTS ...
Page 30: ...6 5 466003 466001 43501A 43500A 44510A 466001 WSZ085 LATCH BOARD PARTS ...
Page 32: ...6 7 56170D 63302A 63303A WTT021 948501 WSZ002 65006B BASE PLATE PARTS ...
Page 33: ...P NO 3828W5S2624 Jan 2003 Printed in Korea ...
Page 35: ...6 2 13581A 14970A 14026A 13552A 13536A 15006A 13213A 13720D 13352A DOOR PARTS ...
Page 36: ...6 3 23572A 249401 26549T 24781T WTP015 CONTROL PANEL PARTS ...
Page 38: ...6 5 466003 466001 43501A 43500A 44510A 466001 WSZ085 LATCH BOARD PARTS ...
Page 40: ...6 7 56170D 63302A 63303A WTT021 948501 WSZ002 65006B BASE PLATE PARTS ...